Functional near-infrared spectroscopy (fNIRS) is an established optical neuroimaging method for measuring functional hemodynamic responses to infer neural activation. However, the impact of individual anatomy on the sensitivity of fNIRS measuring hemodynamics within cortical gray matter is still unknown. By means of Monte Carlo simulations and structural MRI of 23 healthy subjects (mean age: years), we characterized the individual distribution of tissue-specific NIR-light absorption underneath 24 prefrontal fNIRS channels. We, thereby, investigated the impact of scalp-cortex distance (SCD), frontal sinus volume as well as sulcal morphology on gray matter volumes ( ) traversed by NIR-light, i.e. anatomy-dependent fNIRS sensitivity. The NIR-light absorption between optodes was distributed describing a rotational ellipsoid with a mean penetration depth of considering the deepest of light. Of the detected photon packages scalp and bone absorbed and absorbed of the energy. The mean volume was negatively correlated ( ) with the SCD and frontal sinus volume ( ) and was reduced by in subjects with relatively large compared to small frontal sinus. Head circumference was significantly positively correlated with the mean SCD ( ) and the traversed frontal sinus volume ( ). Sulcal morphology had no significant impact on . Our findings suggest to consider individual SCD and frontal sinus volume as anatomical factors impacting fNIRS sensitivity. Head circumference may represent a practical measure to partly control for these sources of error variance.
Objective Deep brain stimulation (DBS) of the ventral intermediate thalamic nucleus (Vim) is established for medically refractory severe essential tremor (ET), but long-term efficacy is controversial. Methods Twenty patients with ET with DBS had standardized video-documented examinations at baseline, in the stimulation-on condition at short term (13.1 ± 1.9 months since surgery, mean ± SEM), and in the stimulator switched on and off (stim-ON/OFF) at long term; all assessments were done between 32 and 120 months (71.9 ± 6.9 months) after implantation. The primary outcome was the Tremor Rating Scale (TRS) blindly assessed by 2 trained movement disorder neurologists. Secondary outcomes were TRS subscores A, B, and C; Archimedes spiral score; and activities of daily living score. At long-term follow-up, tremor was additionally recorded with accelerometry. The rebound effect after switching the stimulator off was assessed for 1 hour in a subgroup. Results Tremor severity worsened considerably over time in both in the nonstimulated and stimulated conditions. Vim-DBS improved the TRS in the short term and long term significantly. The spiral score and functional measures showed similar improvements. All changes were highly significant. However, the stimulation effect was negatively correlated with time since surgery (ρ = −0.78, p < 0.001). This was also true for the secondary outcomes. Only one-third of the patients had a rebound effect terminated 60 minutes after the stimulator was switched off. Long-term worsening of the TRS was more profound during stim-ON than in the stim-OFF condition, indicating habituation to stimulation. Conclusion Vim-DBS loses efficacy over the long term. Efforts are needed to improve the long-term efficacy of Vim-DBS. Classification of evidence This study provides Class IV evidence that for patients with medically refractory severe ET, the efficacy of Vim-DBS severely decreases over 10 years.