Mahdiyeh Bakhtiyari-Ramezani

Dr. Mahdiyeh Bakhtiyari-Ramezani

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MBMahdiyeh Bakhtiyari-Ramezani
Mahdiyeh Bakhtiyari-Ramezani
MNMojtaba Nohekhan
Mojtaba Nohekhan
MAMohammad Esmaeil Akbari
Mohammad Esmaeil Akbari
FAFereshteh Abbasvandi
Fereshteh Abbasvandi
MBMahdis Bayat
Mahdis Bayat
MNMeysam Nasiri
Meysam Nasiri
Recent research has highlighted the promising potential of cold atmospheric plasma (CAP) in cancer therapy. However, variations in study outcomes are attributed to differences in CAP devices and plasma parameters, which lead to diverse compositions of plasma products, including electrons, charged particles, reactive species, UV light, and heat. This study aimed to evaluate and compare the optimal exposure time, duration, and direction-dependent cellular effects of two CAPs, based on argon and helium gases, on glioblastoma U-87 MG cancer cells and an animal model of GBM. Two plasma jets were used as low-temperature plasma sources in which helium or argon gas was ionized by high voltage (4.5 kV) and frequency (20 kHz). In vitro assessments on human GBM and normal astrocyte cell lines, using MTT assays, flow cytometry analysis, wound healing assays, and immunocytochemistry for Caspase3 and P53 proteins, demonstrated that all studied plasma jets, especially indirect argon CAP, selectively induced apoptosis, hindered tumor cell growth, and inhibited migration. These effects occurred concurrently with increased intracellular levels of reactive oxygen species and decreased total antioxidant capacity in the cells. In vivo results further supported these findings, indicating that single indirect argon and direct helium CAP therapy, equal to high dose Temozolomide treatment, induced tumor cell death in a rat model of GBM. This was concurrent with a reduction in tumor size observed through PET-CT scan imaging and a significant increase in the survival rate. Additionally, there was a decrease in GFAP protein levels, a significant GBM tumor marker, and an increase in P53 protein expression based on immunohistochemical analyses. Furthermore, Ledge beam test analysis revealed general motor function improvement after indirect argon CAP therapy, similar to Temozolomide treatment. Taken together, these results suggest that CAP therapy, using indirect argon and direct helium jets, holds great promise for clinical applications in GBM treatment.

27 March 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MBMahdiyeh Bakhtiyari-Ramezani
Mahdiyeh Bakhtiyari-Ramezani
MNMeysam Nasiri
Meysam Nasiri
MBMansoureh Baniasadi
Mansoureh Baniasadi
Nowadays, cold atmospheric plasma (CAP) technology has developed as an innovative tool for cancer therapy. Although many studies have reported the antitumor effects of plasma in vivo and in vitro, there are many challenges, including standardization of plasma devices and treatment time for different tumors. For the first time, we aimed to evaluate and compare optimal exposure time and direction-dependent cellular effects of helium and argon plasma on the 4T1 cancer cells and a triple-negative mouse model of breast cancer. This study used two types of helium and argon plasma jet devices with different input parameters. In vitro evaluations on 4T1 cell line using the MTT assays and flow cytometry analysis demonstrate CAP-induced apoptosis in all treated groups, especially in the direct approach. These changes were concurrent with increased intracellular reactive oxygen species levels and decreased total antioxidant capacity in these cells. In vivo studies concurrent with in vitro results revealed that CAP therapy reduces tumor size, decreases Nottingham histological score, prevents weight loss, and increases the survival rate in all treated groups. These results suggest that plasma therapy may overcome the adverse effects of approved cancer therapeutic strategies and seems to be a significant issue for cancer patients in the clinical stage, alone or in combination with current therapeutic programs.

25 January 2025 in Heliyon
Verified
Journal Article
Open access
MBMahdiyeh Bakhtiyari-Ramezani
Mahdiyeh Bakhtiyari-Ramezani
NZNarges Ziveh
Narges Ziveh
NGNavid Ghaemi
Navid Ghaemi
Organic pollutants originating from industrial discharges pose significant threats to human health and ecological balance. Conventional pretreatment methods face challenges due to high costs, limited efficiency, and the generation of residual sludge. Non-thermal plasma (NTP) technology, a promising advanced oxidation process, has attracted substantial research interest for its potential to rapidly and effectively treat industrial wastewater. This study employed a dielectric barrier discharge (DBD) reactor to investigate the feasibility of low-cost, efficient industrial wastewater treatment through NTP-mediated pollutant degradation. NTP generates reactive oxygen and nitrogen species (RONS), capable of complete organic pollutant oxidation. Wastewater samples from Kaveh Industrial City underwent treatment in a DBD reactor to induce the formation of reactive agents. Water quality parameters, including turbidity, total dissolved solids (TDS), total suspended solids (TSS), chemical oxygen demand (COD), biochemical oxygen demand (BOD5), dissolved oxygen (DO), electrical conductivity (EC), and pH, were measured before and after synergetic plasma treatment. The combination of aeration/filtration and 90 min of plasma treatment significantly reduced turbidity compared to untreated wastewater. A 30-min NTP treatment coupled with aeration/filtration demonstrated superior efficiency in removing TDS and TSS, attributed to NTP-generated active species. Optimal COD and BOD5 removal was achieved through a 24-h aeration, adsorbent filtration, and 30-min NTP process. While standalone 30-min NTP treatment exhibited lower efficiency, the combined aeration/filtration system reduced EC and increased pH with extended plasma exposure. A comparative study of advanced oxidation processes showed that plasma treatment effectively reduced COD by 65 %. Plasma offers a cost-effective and efficient solution for wastewater treatment, despite slightly higher energy consumption. These findings underscore the potential of NTP as a viable strategy for industrial wastewater treatment. The integration of NTP with conventional pretreatment methods offers promising prospects for enhancing wastewater quality and environmental protection.

18 May 2025 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Closed access
MBMahdiyeh Bakhtiyari-Ramezani
Mahdiyeh Bakhtiyari-Ramezani
NJNahid Rezvani Jalal
Nahid Rezvani Jalal
HGHosein Ghasempour
Hosein Ghasempour

27 July 2025 in Waste Management Bulletin
Verified
Journal Article
Open access
MBMahdiyeh Bakhtiyari-Ramezani
Mahdiyeh Bakhtiyari-Ramezani
FMFatemeh Mohammadi
Fatemeh Mohammadi
MAMaryam Azizi
Maryam Azizi
NZNarges Ziveh
Narges Ziveh
FAFatemeh Amani
Fatemeh Amani

1 January 2024 in Plasma Medicine
Verified
Journal Article
Open access
PDF file
MBMahdiyeh Bakhtiyari-Ramezani
Mahdiyeh Bakhtiyari-Ramezani
ANAbootorab Naeimabadi
Abootorab Naeimabadi
FSFatemeh Shakeri
Fatemeh Shakeri
The current investigation was aimed at identifying the potential of plasma activated water as an antiseptic and wound-healing solution. The simplicity and affordability of the indirect approach of plasma therapies led us to evaluate rinsing of wounds via plasma activated water (PAW) and compare to the direct approach of plasma jet. Although previous studies have shown the effectiveness of plasma-activated water in wound healing and disinfection, this study was conducted to investigate two PAWs with various compositions in wound management. In this regard, PAWs with two different treatment times were produced and used for rinsing of wounds. H2O2 and NO2- concentrations as well as acidity values of PAW were measured. Wound healing was investigated to find an efficient solution using Masson trichrome and hematoxylin and eosin staining. The antibacterial effect and wound closure rate of the directly applied plasma jet were significantly improved compared to the PAW treatments. The results exhibited an increase in collagen expression, resulting in the best rate of wound closure. Thus, our results suggested that plasma jet treatment and PAW rinsing of wounds are effective methods without side effects in promoting wound healing.