Andre Childs

Mr. Andre Childs


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2023 in IEEE Sensors Letters
Verified
Journal Article
Closed access
PBPouya Borjian
Pouya Borjian
MCMohammadreza Chimerad
Mohammadreza Chimerad
PPPawan Pathak
Pawan Pathak
ACAndre Childs
Andre Childs
SRSwaminathan Rajaraman
Swaminathan Rajaraman
Hyoung Jin ChoHyoung Jin Cho
Hyoung Jin Cho
Even at low levels heavy metal pollutants significantly threaten the quality of life, posing long-term risks. Current laboratory instrument-based measurement techniques have their limitations due to lengthy preparation and analysis steps. In this study, we introduce a screen-printed electrochemical sensor utilizing non-toxic, biodegradable sodium alginate grafted with 2-acrylamido-2-methyl propane sulfonic acid (AMPS) and conductive fillers for a trace-level lead ion detection in water. The presence of anionic functional groups facilitates chelation through electrostatic interactions, enabling them to preferentially bind to positive lead ions. With the proposed sensor, a low detection limit of 0.1 ppb was obtained by square wave anodic stripping voltammetry. This work demonstrates the effectiveness of an eco-friendly, sustainable sensor construct that takes advantage of enhanced organo-metallic interactions.

11 July 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
MEMonisha Elumalai
Monisha Elumalai
ACAndre Childs
Andre Childs
SWSamantha Williams
Samantha Williams
GAGabriel Arguello
Gabriel Arguello
EMEmily Martinez
Emily Martinez
CDCharles Didier
Charles Didier
Diabetic foot ulcers (DFUs) represent a critical global health issue, necessitating the development of advanced smart, flexible, and wearable sensors for continuous monitoring that are reimbursable within foot orthotics. This study presents the design and characterization of a pressure sensor implemented into a shoe insole to monitor diabetic wound pressures, emphasizing the need for a high sensitivity, durability under cyclic mechanical loading, and a rapid response time. This investigation focuses on the electrical and mechanical properties of carbon nanotube (CNT) composites utilizing Ecoflex and polydimethylsiloxane (PDMS). Morphological characterization was conducted using Transmission Electron Microscopy (TEM), Laser Confocal Microscopy, and Scanning Electron Microscopy (SEM). The electrical and mechanical properties of the CNT/Ecoflex- and the CNT/PDMS-based sensor composites were then investigated. CNT/Ecoflex was then further evaluated due to its lower variability performance between cycles at the same pressure, as well as its consistently higher capacitance values across all trials in comparison to CNT/PDMS. The CNT/Ecoflex composite sensor showed a high sensitivity (2.38 to 3.40 kPa−1) over a pressure sensing range of 0 to 68.95 kPa. The sensor’s stability was further assessed under applied pressures simulating human weight. A custom insole prototype, incorporating 12 CNT/Ecoflex elastomeric matrix-based sensors (as an example) distributed across the metatarsal heads, midfoot, and heel regions, was developed and characterized. Capacitance measurements, ranging from 0.25 pF to 60 pF, were obtained across N = 3 feasibility trials, demonstrating the sensor’s response to varying pressure conditions linked to different body weights. These results highlight the potential of this flexible insole prototype for precise and real-time plantar surface monitoring, offering an approachable avenue for a challenging diabetic orthotics application.

21 December 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
ACAndre Childs
Andre Childs
JPJorge Luis Pereira
Jorge Luis Pereira
CDCharles Didier
Charles Didier
AAliyah Baksh
Aliyah Baksh
IJIsaac Johnson
Isaac Johnson
SRSwaminathan Rajaraman
Swaminathan Rajaraman
Plotter cutters in stencil mask prototyping are underutilized but have several advantages over traditional MEMS techniques. In this paper we investigate the use of a conventional plotter cutter as a highly effective benchtop tool for the rapid prototyping of stencil masks in the sub-250 μm range and characterize patterned layers of organic/inorganic materials. Furthermore, we show a new diagnostic monitoring application for use in healthcare, and a potential replacement of the Standard Kirby-Bauer Diffusion Antibiotic Resistance tests was developed and tested on both Escherichia coli and Xanthomonas alfalfae as pathogens with Oxytetracycline, Streptomycin and Kanamycin. We show that the reduction in area required for the minimum inhibitory concentration tests; allow for three times the number of tests to be performed within the same nutrient agar Petri dish, demonstrated both theoretically and experimentally resulting in correlations of R ≈ 0.96 and 0.985, respectively for both pathogens.

5 April 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
ACAndre Childs
Andre Childs
DCDavid Chand
David Chand
JPJorge Luis Pereira
Jorge Luis Pereira
SSSwadeshmukul Santra
Swadeshmukul Santra
SRSwaminathan Rajaraman
Swaminathan Rajaraman
With the increasing incidence of diverse global bacterial outbreaks, it is important to build an immutable decentralized database that can capture regional changes in bacterial resistance with time. Herein, we investigate the use of a rapid 3D printed µbiochamber with a laser-ablated interdigitated electrode developed for biofilm analysis of Pseudomonas aeruginosa, Acinetobacter baumannii and Bacillus subtilis using electrochemical biological impedance spectroscopy (EBIS) across a 48 h spectrum, along with novel ladder-based minimum inhibitory concentration (MIC) stencil tests against oxytetracycline, kanamycin, penicillin G and streptomycin. Furthermore, in this investigation, a search query database has been built demonstrating the deterministic nature of the bacterial strains with real and imaginary impedance, phase, and capacitance, showing increased bacterial specification selectivity in the 9772.37 Hz range.