Technological advancements are enabling new applications within biomedical engineering. As a connection point between the outer environment and the human system, the oral cavity offers unique opportunities for sensing technologies. This paper systematically reviews the performance of measurement systems tested in the human oral cavity. Performance was defined by metrics related to accuracy and agreement estimation. A comprehensive search identifying human studies that reported on the accuracy or agreement of intraoral sensors found 85 research papers. Most of the literature (62%) was in dentistry, followed by neurology (21%), and physical medicine and rehabilitation (12%). The remaining papers were on internal medicine, obstetrics, and aerospace medicine. Most of the studies applied force or pressure sensors (32%), while optical and image sensors were applied most widely across fields. The main challenges for future adoption include the lack of large human trials, the maturity of emerging technologies (e.g., biochemical sensors), and the absence of standardization of evaluation in specific fields. New research should aim to employ robust performance metrics to evaluate their systems and incorporate real-world evidence as part of the evaluation process. Oral cavity sensors offer the potential for applications in healthcare and wellbeing, but for many technologies, more research is needed.
Accurate body temperature measurement is essential for monitoring and managing safety during outdoor activities. Physical activities are an essential consideration for public health, with sports taking up an important proportion of these. Athletes’ performances can be directly affected by body temperature fluctuations, with overheating or hypothermia posing serious health risks. Monitoring these temperatures allows coaches and medical staff to make decisions that enhance performance and safety. Traditional methods, like oral, axillary, and tympanic readings, are widely used, but face challenges during intense physical activities in real-world environments. This study evaluated the agreement, correlation, and interchangeability of oral, axillary, and tympanic temperature measurements in outdoor exercise conditions. Systems developed for specific placements might generate different sensor readouts. Conducted as an observational field study, it involved 21 adult participants (11 males and 10 females, average age 25.14 ± 5.80 years) that underwent the Yo-Yo intermittent recovery test protocol on an outdoor court. The main outcomes measured were the agreement and correlation between temperature readings from the three methods, both before and after exercise. The results indicate poor agreement between the measurement sites, with significant deviations observed post-exercise. Although the Spearman correlation coefficients showed consistent temperature changes post-exercise across all methods, the standard deviations in the pairwise comparisons exceeded 0.67 °C. This study concluded that widely used temperature measurement methods are challenging to use during outdoor exercises and should not be considered interchangeable. This variability, especially after exercise, underscores the need for further research using gold standard temperature measurement methods to determine the most suitable site for accurate readings. Care should thus be taken when temperature screening is done at scale using traditional methods, as each measurement site should be considered within its own right.
Objective: This study aimed to determine the steady-state errors of oral-based temperature sensors, that are embedded in mouthguards, using a robust assessment process. Materials and methods: Four electronic boards with temperature sensors were encapsulated in mouthguards made from ethylene-vinyl acetate (EVA). The error and time to reach steady-state temperature were determined using a thermostatic water bath during three different conditions (34, 38.5 and 43 °C). Subsequently, a case study of one volunteer wearing the instrumented mouthguard is presented. Results: The water bath tests showed that a mean absolute error of 0.2 °C was reached after a maximum of 690 s across all test conditions. The case study yielded an absolute error was 0.2 °C after 1110 s. Conclusion: These results show that an instrumented mouthguard with temperature sensing capabilities can yield a consistent steady-state error that is close to the clinical requirements across a range of temperatures. However, the time it takes to reach steady-state temperature needs to be considered for these systems to correctly interpret the outcomes.
8 February 2025 in BMJ Open Sport & Exercise Medicine
Objective: The monitoring and diagnosis of sports-related mild traumatic brain injury (SR-mTBI) remains a challenge. This systematic review summarises the current monitoring tools used for on-the-day assessment and diagnosis of SR-mTBI and their performance. Design: Systematic review, using Quality Assessment of Diagnostic Accuracy Studies assessment. Data sources: Embase via Ovid, IEEEXplore, Medline via Ovid, Scopus and Web of Science were searched up to June 2024. Eligibility criteria: Peer-reviewed English-language journal articles which measured athletes using the index test within a day of injury and provided a performance measure for the method used. Studies of all designs were accepted, and no reference methods were required. Results: 2534 unique records were retrieved, with 52 reports included in the review. Participants were 76% male, when reported, and the mean injury-to-measurement time was reported in 10% of reports. 46 different methods were investigated. 38 different reference methods were used, highlighting the lack of gold standard within the field. Area under the curve (AUC), sensitivity and specificity were the most frequent outcome metrics provided. The most frequent index test was the King-Devick (KD) test. However, there were large variations in accuracy metrics between reports for the KD test, for instance, the range of AUC: 0.51–0.92. Conclusion: Combinations of existing methods and the KD test were most accurate in assessing SR-mTBI, despite the inconsistent accuracy values related to the KD test. The absence of a gold-standard measurement hampers our ability to diagnose or monitor SR-mTBI. Further exploration of the mechanisms and time-dependent pathophysiology of SR-mTBI could result in more targeted diagnostic and monitoring techniques. The Podium Institute for Sports Medicine and Technology funded this work. PROSPERO registration number: CRD42022376560.
The reliable monitoring of heart rate during intense exercise is imperative to effectively manage training loads while providing insights from a healthcare perspective. However, current technologies perform poorly in contact sports settings. This study aims to evaluate the best approach for heart rate tracking using photoplethysmography sensors embedded into an instrumented mouthguard (iMG). Seven adults wore iMGs and a reference heart rate monitor. Several sensor placements, light sources and signal intensities were explored for the iMG. A novel metric related to the positioning of the sensor in the gum was introduced. The error between the iMG heart rate and the reference data was assessed to obtain insights into the effect of specific iMG configurations on measurement errors. Signal intensity was found to be the most important variable for error prediction, followed by the sensor light source, sensor placement and positioning. A generalized linear model combining an infrared light source, at an intensity of 5.08 mA, and a frontal placement high in the gum area resulted in a heart rate minimum error of 16.33%. This research shows promising preliminary results for the use of oral-based heart rate monitoring, but highlights the need for the careful consideration of sensor configurations within these systems.
27 January 2025 in Sensors and Actuators A: Physical