Yiping Chen

Dr. Yiping Chen


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2018 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
YXYunlei Xianyu
Yunlei Xianyu
JWJing Wu
Jing Wu
YCYiping Chen
Yiping Chen
WZWenshu Zheng
Wenshu Zheng
MXMengxia Xie
Mengxia Xie
XJXingyu Jiang
Xingyu Jiang

1 August 2017 in Analytica Chimica Acta
Verified
Journal Article
Closed access
JWJing Wu
Jing Wu
YCYiping Chen
Yiping Chen
MYMingzhu Yang
Mingzhu Yang
YWYu Wang
Yu Wang
CZCheng Zhang
Cheng Zhang
XJXingyu Jiang
Xingyu Jiang

1 December 2016 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Binfeng YinBinfeng Yin
Binfeng Yin
YWYu Wang
Yu Wang
MDMingling Dong
Mingling Dong
JWJing Wu
Jing Wu
BRBei Ran
Bei Ran
YCYiping Chen
Yiping Chen

5 June 2017 in Sensors
Verified
Journal Article
Open access
PDF file
JWJing Wu
Jing Wu
MDMingling Dong
Mingling Dong
CZCheng Zhang
Cheng Zhang
YWYu Wang
Yu Wang
MXMengxia Xie
Mengxia Xie
YCYiping Chen
Yiping Chen
Magnetic lateral flow strip (MLFS) based on magnetic bead (MB) and smart phone camera has been developed for quantitative detection of cocaine (CC) in urine samples. CC and CC-bovine serum albumin (CC-BSA) could competitively react with MB-antibody (MB-Ab) of CC on the surface of test line of MLFS. The color of MB-Ab conjugate on the test line relates to the concentration of target in the competition immunoassay format, which can be used as a visual signal. Furthermore, the color density of the MB-Ab conjugate can be transferred into digital signal (gray value) by a smart phone, which can be used as a quantitative signal. The linear detection range for CC is 5–500 ng/mL and the relative standard deviations are under 10%. The visual limit of detection was 5 ng/mL and the whole analysis time was within 10 min. The MLFS has been successfully employed for the detection of CC in urine samples without sample pre-treatment and the result is also agreed to that of enzyme-linked immunosorbent assay (ELISA). With the popularization of smart phone cameras, the MLFS has large potential in the detection of drug residues in virtue of its stability, speediness, and low-cost.

1 May 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
XLXiaoxia Liu
Xiaoxia Liu
XSXingda Song
Xingda Song
ZDZhiyong Dong
Zhiyong Dong
XMXiaoting Meng
Xiaoting Meng
YCYiping Chen
Yiping Chen
XXXuexue Xu
Xuexue Xu

30 June 2017 in The Analyst
Verified
Journal Article
Closed access
PDF file
Binfeng YinBinfeng Yin
Binfeng Yin
WZWenshu Zheng
Wenshu Zheng
MDMingling Dong
Mingling Dong
WYWenbo Yu
Wenbo Yu
YCYiping Chen
Yiping Chen
XJXingyu Jiang
Xingyu Jiang
We developed a competitive colorimetric nanosensor based on Au@Ag bimetallic nanoparticles for the detection of interleukin-6 (IL-6) in clinical samples. Antibody-conjugated magnetic nanoparticles (MNPs) and polystyrene (PS) microparticles conjugated with both catalase and a secondary antibody can form sandwich structures that enable one-step target enrichment and separation. The catalase on the surface of the PS can catalyze the hydrolysis of hydrogen peroxide (H2O2) to regulate the deposition of Ag+ on the surface of gold nanoparticles (AuNPs), and forms different sizes and amounts of Au@Ag bimetallic nanoparticles (Au@AgNPs) which produce a distinct color signal for readout with the naked eye. Our sensor features high sensitivity, selectivity, reproducibility and anti-interference property as a result of comprehensive parameter optimization. The limit of detection of IL-6 can reach 11 pg mL−1 with the naked eye and 1.2 pg mL−1 by quantitative instrumental analysis. The whole analysis can be finished within 1 h. More importantly, we successfully apply our platform or the detection of IL-6 in clinical samples with better accuracy than conventional enzyme-linked immunosorbent assay (ELISA).