Michael Holzinger

Dr. Michael Holzinger

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2002 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
VGVasilios Georgakilas
Vasilios Georgakilas
Konstantinos KordatosKonstantinos Kordatos
Konstantinos Kordatos
MPMaurizio Prato
Maurizio Prato
DGDirk M. Guldi
Dirk M. Guldi
MHMichael Holzinger
Michael Holzinger
AHAndreas Hirsch
Andreas Hirsch

27 August 2014 in Frontiers in Chemistry
Verified
Journal Article
Open access
PDF file
MHMichael Holzinger
Michael Holzinger
AGAlan Le Goff
Alan Le Goff
SCSerge Cosnier
Serge Cosnier
A biosensor device is defined by its biological, or bioinspired receptor unit with unique specificities toward corresponding analytes. These analytes are often of biological origin like DNAs of bacteria or viruses, or proteins which are generated from the immune system (antibodies, antigens) of infected or contaminated living organisms. Such analytes can also be simple molecules like glucose or pollutants when a biological receptor unit with particular specificity is available. One of many other challenges in biosensor development is the efficient signal capture of the biological recognition event (transduction). Such transducers translate the interaction of the analyte with the biological element into electrochemical, electrochemiluminescent, magnetic, gravimetric, or optical signals. In order to increase sensitivities and to lower detection limits down to even individual molecules, nanomaterials are promising candidates due to the possibility to immobilize an enhanced quantity of bioreceptor units at reduced volumes and even to act itself as transduction element. Among such nanomaterials, gold nanoparticles, semi-conductor quantum dots, polymer nanoparticles, carbon nanotubes, nanodiamonds, and graphene are intensively studied. Due to the vast evolution of this research field, this review summarizes in a non-exhaustive way the advantages of nanomaterials by focusing on nano-objects which provide further beneficial properties than “just” an enhanced surface area.

28 June 2011 in Nature Communications
Verified
Journal Article
Open access
PDF file
AZAbdelkader Zebda
Abdelkader Zebda
CGChantal Gondran
Chantal Gondran
AGAlan Le Goff
Alan Le Goff
MHMichael Holzinger
Michael Holzinger
PCPhilippe Cinquin
Philippe Cinquin
SCSerge Cosnier
Serge Cosnier
Enzymatic fuel cells use enzymes to produce energy from bioavailable substrates. However, such biofuel cells are limited by the difficult electrical wiring of enzymes to the electrode. Here we show the efficient wiring of enzymes in a conductive pure carbon nanotube matrix for the fabrication of a glucose biofuel cell (GBFC). Glucose oxidase and laccase were respectively incorporated in carbon nanotube disks by mechanical compression. The characterization of each bioelectrode shows an open circuit potential corresponding to the redox potential of the respective enzymes, and high current densities for glucose oxidation and oxygen reduction. The mediatorless GBFC delivers a high power density up to 1.3 mW cm−2 and an open circuit voltage of 0.95 V. Moreover, the GBFC remains stable for 1 month and delivers 1 mW cm−2 power density under physiological conditions (5×10−3 mol l−1 glucose, pH 7). To date, these values are the best performances obtained for a GBFC.

31 October 2001 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
MHMichael Holzinger
Michael Holzinger
OVOtto Vostrowsky
Otto Vostrowsky
AHAndreas Hirsch
Andreas Hirsch
FHFrank Hennrich
Frank Hennrich
MKManfred Kappes
Manfred Kappes
FJFrank Jellen
Frank Jellen

20 June 2003 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
MHMichael Holzinger
Michael Holzinger
JAJuergen Abraham
Juergen Abraham
PWPaul Whelan
Paul Whelan
RGRalf Graupner
Ralf Graupner
LLLothar Ley
Lothar Ley
AHAndreas Hirsch
Andreas Hirsch

22 March 2013 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AZA. Zebda
A. Zebda
SCS. Cosnier
S. Cosnier
JAJ.-P. Alcaraz
J.-P. Alcaraz
MHMichael Holzinger
Michael Holzinger
AGAlan Le Goff
Alan Le Goff
PCP. Cinquin
P. Cinquin
We describe the first implanted glucose biofuel cell (GBFC) that is capable of generating sufficient power from a mammal's body fluids to act as the sole power source for electronic devices. This GBFC is based on carbon nanotube/enzyme electrodes, which utilize glucose oxidase for glucose oxidation and laccase for dioxygen reduction. The GBFC, implanted in the abdominal cavity of a rat, produces an average open-circuit voltage of 0.57 V. This implanted GBFC delivered a power output of 38.7 μW, which corresponded to a power density of 193.5 μW cm−2 and a volumetric power of 161 μW mL−1. We demonstrate that one single implanted enzymatic GBFC can power a light-emitting diode (LED), or a digital thermometer. In addition, no signs of rejection or inflammation were observed after 110 days implantation in the rat.