Jiasi Mo

Dr. Jiasi Mo

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2024 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
JCJianhuan Chen
Jianhuan Chen
QCQiushuo Chen
Qiushuo Chen
DLDeyu Liang
Deyu Liang
JMJiasi Mo
Jiasi Mo

1 January 2020 in International Journal of Agricultural and Biological Engineering
Verified
Journal Article
Open access
PDF file
GYGuoqi Yan
Guoqi Yan
PTPeng Tian
Peng Tian
JMJiasi Mo
Jiasi Mo
HXHeng Xie
Heng Xie
HWHuiling Wei
Huiling Wei
Low-velocity resistance distortion and bionic drag reduction for ship-type paddy field machinery

4 August 2025 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
YWYuanhang Wen
Yuanhang Wen
JLJiejun Liang
Jiejun Liang
JLJialong Luo
Jialong Luo
PZPeikang Zhou
Peikang Zhou
GZGuanlin Zhong
Guanlin Zhong
JMJiasi Mo
Jiasi Mo

1 January 2023 in International Journal of Agricultural and Biological Engineering
Verified
Journal Article
Open access
PDF file
QLQing Liu
Qing Liu
Yuxing HanYuxing Han
Yuxing Han
GYGuoqi Yan
Guoqi Yan
JMJiasi Mo
Jiasi Mo
ZYZishang Yang
Zishang Yang
To obtain higher economic benefits, large eel breeding companies classify live eels by weight. Due to their strong mobility and smooth body surface, living eels are not suitable for traditional mechanical weight measurement. In this study, a live eel sorting machine based on machine vision was developed, and a novel method was developed for obtaining live eel weight measurements through images. First, a backlit workbench was designed to capture static images of eels, and then the projection area and skeleton length of the images were obtained by image preprocessing. For the eel's body shape, which is generally cylindrical and gradually transitions to a flat tail, the tail posture changes affect the shape of the images; thus, a weight measurement model combining the projected area and the skeleton length was proposed. The optimal scale division coefficient of the weight model was found to be 0.745 by experimentation. Then, select eels of different weight ranges were used for model error verification and to obtain the correction function of the error. The weight gradient was used to confirm the corrected eel weight model. Finally, the system calculation results were compared with the actual measurement results. The root mean square error (RMSE) was 12.94 g, and the mean absolute percentage error (MAPE) was 2.12%. The results show that the proposed method provided a convenient, fast, and low-cost non-contact weight measurement method for live eels, reduced the damage rate of live eels, and can meet the technical requirements of actual production. Keywords: scale factor, weight measurement, non-contact, live eels DOI: 10.25165/j.ijabe.20231602.7132 Citation: Liu Q, Han Y X, Yan G Q, Mo J S, Yang Z S. Posture-invariant hybrid scaling weight measurement algorithm for live eels. Int J Agric & Biol Eng, 2023; 16(2): 207-215.

22 February 2023 in Agriculture
Verified
Journal Article
Open access
PDF file
GYGuoqi Yan
Guoqi Yan
JQJialei Qu
Jialei Qu
WLWei Li
Wei Li
DCDongyi Chen
Dongyi Chen
CZChumin Zhong
Chumin Zhong
JMJiasi Mo
Jiasi Mo
Once the Pericarp of Citri Reticulata ‘Chachi’ (PCRC) develops mildew while in storage, the rapid spread of the flora after the occurrence of mold can cause huge losses. As such, inspecting whether the PCRC is moldy is important. In this paper, we propose an alternative inspection method, namely that of utilizing a small UAV with a camera to inspect the PCRC mildew in the top stacks under consideration. Specifically, we first address the light problem in the collected images with different lights via a multi-spectral method, and find that 625–740 nm of lighting has a significant effect on mildew. Second, we utilize the ultrared 1.4R-G method to extract the features of mildew with Otus binarization. We can see that the mold-free area is less than 95% in an image categorized as having mildew. The proposed mildew inspection method achieved 93.3% accuracy. Our method could send the inspection information to a control system, achieving rapid closed-loop automatic control and reducing the mildew-related loss.

19 December 2025 in Mechanical Sciences
Verified
Journal Article
Open access
PDF file
JCJianhuan Chen
Jianhuan Chen
YWYuanhang Wen
Yuanhang Wen
DLDeyu Liang
Deyu Liang
JLJiejun Liang
Jiejun Liang
CSChuntian Song
Chuntian Song
JMJiasi Mo
Jiasi Mo
Rigid-flexible coupling is the development trend of lightweight parallel mechanisms. Different from traditional rigid parallel mechanisms, although the flexible components are light in weight, the large elastic deformation generated by the mechanism will affect the precision and stability of the movement. The elastic deformation of the flexible components makes the kinematic modeling challenging, which limits the application and promotion of such mechanisms. To solve the kinematic problems of such mechanisms and improve motion accuracy, this paper takes the rigid-flexible coupling parallel mechanism driven by elastic thin rods as the research object, proposes an inverse geometrico-static problem (IGP) solution, and conducts relevant motion tests to verify the correctness of the solution. Firstly, to solve the geometric relationship between the elastic thin rods and the end of the mechanism during the motion of the mechanism, the rigid-flexible coupling parallel mechanism driven by the elastic thin rods is rigidified and equivalent to a four-cable traction parallel robot, and the rationality of the rigidification equivalence is analyzed. Secondly, the kinematic/static coupling problem (geometrico-static problem) of the four-cable parallel robot is solved by the numerical iteration method, and a simulation example is analyzed, which shows that the cable length and Euler angle are cosine-like functions, the center of gravity distance is negatively correlated with the Euler angle amplitude, and the height and gravity of the end effector are independent of it. Thirdly, for the inverse kinematics problem of the rigid-flexible coupling parallel mechanism driven by elastic thin rods, a method combining the planar chain beam model and the kinematic model of the four-cable parallel robot is proposed. Finally, two experimental platforms are built to test and verify the accuracy of the above kinematic models. The test of the four-cable robot shows that the Fréchet distances of the target trajectories and the actual trajectories are relatively small (near 1), and the test of the rigid-flexible coupling parallel mechanism shows that the maximum errors between the target trajectories and the actual trajectories are all no more than 1.5 mm. The results all indicate that the target trajectories and the actual trajectories are highly consistent, which proves that the models and numerical iterative method are highly accurate. The method proposed in this paper can effectively solve the IGP of similar mechanisms and provide theoretical support for its practical application.