Photobiomodulation has analgesic effects via inhibition of nerve activity, but few reports have examined the effects on the spinal dorsal horn, the entry point for nociceptive information in the central nervous system. In this study, we evaluated the effects of laser irradiation of peripheral nerve axons, which are conduction pathways for nociceptive stimuli, on the neuronal firing in lamina II of the spinal dorsal horn of a rat evoked by mechanical stimulation with von Frey filaments (vFF). In order to record neuronal firing, electrodes were inserted into lamina II of the exposed rat spinal dorsal horn. The exposed sciatic nerve axons were irradiated with an 808 nm laser. The 26.0 g vFF-evoked firing frequency was inhibited from 5 min after laser irradiation and persisted for 3 h. Sham irradiation did not alter the firing frequency. Laser irradiation selectively inhibited 15.0 and 26.0 g vFF-evoked firing, which corresponded to nociceptive stimuli. Histopathological evaluation revealed no damage to the sciatic nerve due to laser irradiation. These results indicate that neuronal firing is inhibited in lamina II of the spinal dorsal horn, suggesting that laser irradiation inhibits Aδ and/or C fibers that conduct nociceptive stimuli.
Photobiomodulation is an effective treatment for pain. We previously reported that the direct laser irradiation of the exposed sciatic nerve inhibited firing in the rat spinal dorsal horn evoked by mechanical stimulation, corresponding to the noxious stimulus. However, percutaneous laser irradiation is used in clinical practice, and it is unclear whether it can inhibit the firing of the dorsal horn. In this study, we investigated whether the percutaneous laser irradiation of the sciatic nerve inhibits firing. Electrodes were inserted into the lamina II of the dorsal horn, and mechanical stimulation was applied using von Frey filaments (vFFs) with both pre and post laser irradiation. Our findings show that percutaneous laser irradiation inhibited 26.0 g vFF-evoked firing, which corresponded to the noxious stimulus, but did not inhibit 0.6 g and 8.0 g vFF-evoked firing. The post- (15 min after) and pre-irradiation firing ratios were almost the same as those for direct and percutaneous irradiation. A photodiode sensor implanted in the sciatic nerve showed that the power density reaching the sciatic nerve percutaneously was attenuated to approximately 10% of that on the skin. The relationship between the laser intensity reaching the nerve and its effect could be potentially useful for a more appropriate setting of laser conditions in clinical practice.
30 March 2024 in Biochemical and Biophysical Research Communications
The purpose of this study is to explore the potential application of photobiomodulation to irritable bowel syndrome. We established the following experimental groups: the Non-Stress + Sham group, which consisted of rats that were not restrained and were only subjected to sham irradiation; the Stress + Sham group, which underwent 1 hour of restraint stress followed by sham irradiation; and the Stress + Laser group, which was subjected to restraint stress and percutaneous laser irradiation bilaterally on the L6 dorsal root ganglia for 5 minutes each. The experiment was conducted twice, with three and two laser conditions examined. Following laser irradiation, a barostat catheter was inserted into the rat’s colon. After a 30-minute acclimatization period, the catheter was inflated to a pressure of 60 mmHg, and the number of abdominal muscle contractions was measured over a 5-minute period. The results showed that photobiomodulation significantly suppressed the number of abdominal muscle contractions at average powers of 460, 70, and 18 mW. However, no significant suppression was observed at average powers of 1 W and 3.5 mW. This study suggests that photobiomodulation can alleviate visceral hyperalgesia induced by restraint stress, indicating its potential applicability to irritable bowel syndrome.
4 July 2024 in Biochemical and Biophysical Research Communications
The therapeutic benefits of photobiomodulation (PBM) in pain management, although well documented, are accompanied by concerns about potential risks, including pain, particularly at higher laser intensities. This study investigated the effects of laser intensity on pain perception using behavioral and electrophysiological evaluations in rats. Our results show that direct laser irradiation of 1000 mW/cm2 to the sciatic nerve transiently increases the frequency of spontaneous firing in the superficial layer without affecting the deep layer of the spinal dorsal horn, and this effect reverses to pre-irradiation levels after irradiation. Interestingly, laser irradiation at 1000 mW/cm2, which led to an increase in spontaneous firing, did not prompt escape behavior. Furthermore, a significant reduction in the time to initiate escape behavior was observed only at 9500 mW/cm2 compared to 15, 510, 1000, and 4300 mW/cm2. This suggests that 1000 mW/cm2, the laser intensity at which an increase in spontaneous firing was observed, corresponds to a stimulus that did not cause pain. It is expected that a detailed understanding of the risks and mechanisms of PBM from a neurophysiological perspective will lead to safer and more effective use of PBM.
Objective: Photobiomodulation selectively controls the activity of the sensory nervous system associated with A-delta and C fibers. Hypersensitivity involving the afferent A-delta and C fibers occurs in cystitis and decreases urinary function. This study aimed to investigate the effect of photobiomodulation on urinary storage dysfunction and voiding functions in cystitis model rats. Methods: We prepared the rat cystitis model. Under anesthesia, a cannula was connected to the bladder via a ventral incision. 0.3% acetic acid or saline was injected into the bladder. Continuous cystometry was performed, measuring bladder pressure and voiding urine volume with rats freely mobile. Laser irradiation was applied to the L6 lumbosacral intervertebral foramen using an 830 nm laser. Residual urine was extracted post-cystometry. Results: In the rat cystitis model groups, there was a significant decrease in the voiding interval and volume compared to the group receiving normal saline infusion. After sham or laser irradiation, only the group with laser irradiation showed a significant increase in voiding interval (217%, p = 0.0002) and voiding volume (192%, p = 0.0012) in the parameters of storage dysfunction. The basal pressure, intravesical pressure, and residual urine volume remained unchanged in all groups before and after irradiation. Conclusions: This study indicates that photobiomodulation may improve urine storage dysfunction without exacerbating voiding function in a rat model of cystitis. Thus, photobiomodulation may be a new treatment option for the hypersensitivity and detrusor overactivity caused by cystitis.