To develop radiomics models based on multi-sequence MRI from two centers for the preoperative prediction of the WHO/ISUP grade of Clear Cell Renal Cell Carcinoma (ccRCC). This retrospective study included 334 ccRCC patients from two centers. Significant clinical factors were identified through univariate and multivariate analyses. MRI sequences included Dynamic contrast-enhanced MRI, axial fat-suppressed T2-weighted imaging, diffusion-weighted imaging, and in-phase/out-of-phase images. Feature selection methods and logistic regression (LR) were used to construct clinical and radiomics models, and a combined model was developed using the Rad-score and significant clinical factors. Additionally, seven classifiers were used to construct the combined model and different folds LR was used to construct the combined model to evaluate its performance. Models were evaluated using receiver operating characteristic (ROC) curves, area under the curve (AUC), and decision curve analysis (DCA). The Delong test compared ROC performance, with p < 0.050 considered significant. Multivariate analysis identified intra-tumoral vessels as an independent predictor of high-grade ccRCC. In the external validation set, the radiomics model (AUC = 0.834) outperformed the clinical model (AUC = 0.762), with the combined model achieving the highest AUC (0.855) and significantly outperforming the clinical model (p = 0.003). DCA showed that the combined model had a higher net benefit within the 0.04–0.54 risk threshold range than clinical model. Additionally, the combined model constructed using logistic regression has a higher priority compared to other classifiers. Additionally, 10-fold cross-validation with LR for the combined model showed consistent AUC values (0.849–0.856) across different folds. The radiomics models based on multi-sequence MRI might be a noninvasive and effective tool, demonstrating good efficacy in preoperatively predicting the WHO/ISUP grade of ccRCC.
Rationale: Gadolinium-based contrast agents (GBCAs), benefiting from good tolerance and safety, become the priority contrast agents in magnetic resonance imaging. Serious hypersensitivity reactions caused by GBCAs are rare, but occur occasionally. The “immune surveillance” theory proposes that lowered immune function exists in patients with malignance, which decrease the occurrence of atopy. Natural immunosurveillance that enhanced by effective treatment of malignance may increase the risk of hypersensitivity. Patient concerns: A 29-year-old female patient suffering from intensive pain with left leg mass was admitted in our hospital. Diagnoses: The patient was diagnosed with alveolar soft part sarcoma by histopathology and revealed destruction of the left fibula and lung metastasis by computed tomography scan, and treated with anlotinib hydrochloride, a multi-targeted tyrosine kinase inhibitor. After 4 cycles of effective targeted therapy, the patient developed severe immediate hypersensitivity due to gadopentetate dimeglumine-enhanced magnetic resonance imaging. Interventions and outcomes: The vital signs of the patient returned to normal after rescue. Since then, the patient has not used gadolinium contrast agent again, and currently the condition is stable and still alive. Lessons: Severe immediate hypersensitivity might be occurred by gadolinium contrast agent in patients with malignance after effective treatment. We explored the potential mechanism of GBCA-inducing hypersensitivity in detail, by especially focusing on the changes of immune environment. Furthermore, we propose new ideas for the safe use of GBCAs in patients with malignancies.
Accurate preoperative risk stratification is critical for treating thymic epithelial tumors (TETs). This study developed a deep learning framework that combines a dual-channel convolutional neural network (CNN) with an adaptive dynamic clustering algorithm. The model was trained on contrast-enhanced CT (CECT) images from 336 multicenter TET patients. It first automates the segmentation of tumor subregions. Then, it constructs dual-channel input data containing the largest cross-sectional ROI and its corresponding habitat masks. Using transfer learning, we trained four CNN architectures for risk stratification. The DenseNet121-based dual-channel CNN achieved an AUC of 0.74–0.76 on an external test set. This performance surpassed conventional radiomics, single-channel CNN, and radiologists’ visual assessment. Our framework effectively captures intratumoral heterogeneity, improves risk stratification accuracy, and aids in rapid identification of high-risk patients. This approach can support personalized treatment planning.
The study aims to evaluate the potential value of a CT nomogram in predicting overall survival in patients with diffuse large B-cell lymphoma (DLBCL) after
To develop an intratumor heterogeneity (ITH)-aware deep learning (DL) framework for preoperative prediction of lymph node metastasis (LNM) in laryngeal squ