Imre Szalóki

Prof. Imre Szalóki

Nuclear Security Department, Centre for Energy Research, Budapest, Hungary

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

31 October 2016 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
ISImre Szalóki
Imre Szalóki
AGA. Gerényi
A. Gerényi
GRG. Radócz
G. Radócz
ALA. Lovas
A. Lovas
BSB. De Samber
B. De Samber
LVL. Vincze
L. Vincze
A novel quantitative reconstruction model for synchrotron-based confocal X-ray fluorescence imaging has been developed and validated.

17 June 2019 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Open access
PDF file
ISImre Szalóki
Imre Szalóki
TPT Pintér
T Pintér
ISImre Szalóki
Imre Szalóki
GRG Radócz
G Radócz
AGA Gerényi
A Gerényi
A new table-top combined spectrometer was designed and constructed consisting of X-ray fluorescence and Raman spectrometers for spot-analysis of elementary and chemical composition of solid and liquid substances for industrial analytical applications. For XRF analysis a silicon drift detector and an air-cooled low-power transmission type X-ray tube were built in the combined XRF-Raman spectrometer. Both spectrometer units were connected hermetically to a sealed radiation chamber that can be optionally evacuated or it can be filled with helium under atmospheric pressure in order to improve the analytical sensitivity in the region of low-atomic numbers. The XRF and the Raman devices operate in a confocal geometrical arrangement, where the three axes of the Raman laser beam, the exciter X-ray beam, and the X-ray detection channel focus on the same spot of the examined object. The confocal spot of the combined spectrometer can be positioned along the vertical axis with an optional selected step-size of over 0.2 mm. For the precise geometrical adjustment of the focal spot on the sample surface an optical positioning system was designed and built into the irradiation chamber consisting of a mini camera and two mini laser modules. A new FPM model, its algorithm of numerical solution and software were developed for quantitative XRF analysis. The FPM model is based on application of a series of virtual monochromatic X-ray sources used for excitation of the sample elements substituting the experimentally determined spectra of the X-ray tube. The numerical FPM calculations were performed in a matrix-oriented MATLAB programming environment by using self-made software. The model uses both K- and L-lines for the improvement of the accuracy of the calculations and to extend the range of the atomic number of the analysed chemical elements. This FPM model is suitable for the calculation of the concentrations of chemical elements in 4–5 orders of magnitude for liquid and solid materials. In order to maximise the analytical information simultaneous analyses of the Cu content were performed by Raman and XRF spectrometry in an aqueous solution of CuSO4 and citric acid. This experiment proved the synergy of the combined use of these two analytical methods, since both molecular and atomic composition could be analysed quantitatively in the same liquid sample.

31 May 2017 in X-Ray Spectrometry
Verified
Journal Article
Closed access
PDF file
ISImre Szalóki
Imre Szalóki
AGA. Gerényi
A. Gerényi
GRG. Radócz
G. Radócz

25 November 2022 in Plants
Verified
Journal Article
Open access
PDF file
FKFlóra Kolberg
Flóra Kolberg
Brigitta TóthBrigitta Tóth
Brigitta Tóth
DRDEEPALI RANA
DEEPALI RANA
VSVitor Arcoverde Cerveira Sterner
Vitor Arcoverde Cerveira Sterner
AGAnita Gerényi
Anita Gerényi
Ferenc FodorFerenc Fodor
Ferenc Fodor
Thinopyrum obtusiflorum (syn. Elymus elongatus subsp. ponticus) cv. Szarvasi-1 (Poaceae, Triticeae) is a biomass plant with significant tolerance to certain metals. To reveal its accumulation capacity, we investigated its Zn uptake and tolerance in a wide range: 0.2 to 1000 µM Zn concentration. The root and shoot weight, shoot length, shoot water content and stomatal conductance proved to be only sensitive to the highest applied Zn concentrations, whereas the concentration of malondialdehyde increased only at the application of 1 mM Zn in the leaves. Although physiological status proved to be hardy against Zn exposure, shoot Zn content significantly increased in parallel with the applied Zn treatment, reaching the highest Zn concentration at 1.9 mg g−1 dry weight. The concentration of K, Mg and P considerably decreased in the shoot at the highest Zn exposures, where that of K and P also correlated with a decrease in water content. Although the majority of microelements remained unaffected, Mn decreased in the root and Fe content had a negative correlation with Zn both in the shoot and root. In turn, the application of excessive EDTA maintained a proper Fe supply for the plants but lowered Zn accumulation both in roots and shoots. Thus, the Fe-Zn competition for Fe chelating phytosiderophores and/or for root uptake transporters fundamentally affects the Zn accumulation properties of Szarvasi-1. Indeed, the considerable Zn tolerance of Szarvasi-1 has a high potential in Zn accumulation.

7 April 2020 in X-Ray Spectrometry
Verified
Journal Article
Open access
PDF file
ISImre Szalóki
Imre Szalóki
AGAnita Gerényi
Anita Gerényi
GRGábor Radócz
Gábor Radócz
Reverse Monte Carlo iterative algorithm has been developed for quantification of energy‐dispersive X‐ray fluorescence analysis in order to calculate the concentrations of the elementary composition in solid substances. The core of the simulation code was the MCNP6 that is a well‐established and widely applied software package in the nuclear research and practice for simulation of nuclear systems or the full process of gamma‐ or X‐ray spectrometry. The reverse Monte Carlo algorithm and the full analytical procedure was tested by quantitative XRF analysis of reference alloy samples. The atomic compositions of the reference samples were determined by reverse Monte Carlo technique and also fundamental parameter method and by spark emission atomic spectroscopy. The agreement between the results of these three analytical methods was found within the standard deviations of the major elements of the samples. The total duration of the reverse Monte Carlo numerical computation was minimized to a few minutes using the variance reduction procedures available in the MCNP6.