Abderrahim Halimi

Dr. Abderrahim Halimi


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2011 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
AHAbderrahim Halimi
Abderrahim Halimi
YAYoann Altmann
Yoann Altmann
NDNicolas Dobigeon
Nicolas Dobigeon
JTJean-Yves Tourneret
Jean-Yves Tourneret
Nonlinear models have recently shown interesting properties for spectral unmixing. This paper studies a generalized bilinear model and a hierarchical Bayesian algorithm for unmixing hyperspectral images. The proposed model is a generalization not only of the accepted linear mixing model but also of a bilinear model that has been recently introduced in the literature. Appropriate priors are chosen for its parameters to satisfy the positivity and sum-to-one constraints for the abundances. The joint posterior distribution of the unknown parameter vector is then derived. Unfortunately, this posterior is too complex to obtain analytical expressions of the standard Bayesian estimators. As a consequence, a Metropolis-within-Gibbs algorithm is proposed, which allows samples distributed according to this posterior to be generated and to estimate the unknown model parameters. The performance of the resulting unmixing strategy is evaluated via simulations conducted on synthetic and real data.

12 May 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
APAgata M. Pawlikowska
Agata M. Pawlikowska
AHAbderrahim Halimi
Abderrahim Halimi
RLRobert A. Lamb
Robert A. Lamb
GBGerald S. Buller
Gerald S. Buller
Depth and intensity profiling of targets at a range of up to 10 km is demonstrated using time-of-flight time-correlated single-photon counting technique. The system comprised a pulsed laser source at 1550 nm wavelength, a monostatic scanning transceiver and a single-element InGaAs/InP single-photon avalanche diode (SPAD) detector. High-resolution three-dimensional images of various targets acquired over ranges between 800 metres and 10.5 km demonstrate long-range depth and intensity profiling, feature extraction and the potential for target recognition. Using a total variation restoration optimization algorithm, the acquisition time necessary for each pixel could be reduced by at least a factor of ten compared to a pixel-wise image processing approach. Kilometer range depth profiles are reconstructed with average signal returns of less than one photon per pixel.

13 February 2012 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
YAYoann Altmann
Yoann Altmann
AHAbderrahim Halimi
Abderrahim Halimi
NDNicolas Dobigeon
Nicolas Dobigeon
JTJean-Yves Tourneret
Jean-Yves Tourneret
This paper presents a nonlinear mixing model for hyperspectral image unmixing. The proposed model assumes that the pixel reflectances are nonlinear functions of pure spectral components contaminated by an additive white Gaussian noise. These nonlinear functions are approximated using polynomial functions leading to a polynomial postnonlinear mixing model. A Bayesian algorithm and optimization methods are proposed to estimate the parameters involved in the model. The performance of the unmixing strategies is evaluated by simulations conducted on synthetic and real data.

8 February 2019 in Optics Express
Verified
Journal Article
Open access
PDF file
RTRachael Tobin
Rachael Tobin
AHAbderrahim Halimi
Abderrahim Halimi
AMAongus McCarthy
Aongus McCarthy
MLMartin Laurenzis
Martin Laurenzis
FCFrank Christnacher
Frank Christnacher
GBGerald S. Buller
Gerald S. Buller
We investigate the depth imaging of objects through various densities of different obscurants (water fog, glycol-based vapor, and incendiary smoke) using a time-correlated single-photon detection system which had an operating wavelength of 1550 nm and an average optical output power of approximately 1.5 mW. It consisted of a monostatic scanning transceiver unit used in conjunction with a picosecond laser source and an individual Peltier-cooled InGaAs/InP single-photon avalanche diode (SPAD) detector. We acquired depth and intensity data of targets imaged through distances of up to 24 meters for the different obscurants. We compare several statistical algorithms which reconstruct both the depth and intensity images for short data acquisition times, including very low signal returns in the photon-starved regime.

22 April 2020 in IEEE Transactions on Vehicular Technology
Verified
Journal Article
Open access
AWAndrew Wallace
Andrew Wallace
AHAbderrahim Halimi
Abderrahim Halimi
GBGerald Buller
Gerald Buller
We present and discuss the case for full waveform pixel and image acquisition and processing to enable LIDAR sensors to penetrate and reconstruct 3D surface maps through obscuring media. To that end, we review work on signal propagation, on scanning and arrayed sensors, on signal processing strategies for independent pixels and employing spatial context, on reducing complexity and accelerating processing by sensor design, algorithmic changes, compressed sensing, and parallel processing. We report several experimental studies on LiDAR imaging through complex media, and how these can inform the automotive LiDAR scenario. We conclude with a discussion of future development and potential for full waveform LiDAR (FWL).

15 February 2017 in IEEE Transactions on Computational Imaging
Verified
Journal Article
Open access
AHAbderrahim Halimi
Abderrahim Halimi
AMAurora Maccarone
Aurora Maccarone
AMAongus McCarthy
Aongus McCarthy
SMSteve McLaughlin
Steve McLaughlin
GBGerald Buller
Gerald Buller
This paper presents two new algorithms for the joint restoration of depth and reflectivity (DR) images constructed from time-correlated single-photon counting measurements. Two extreme cases are considered: 1) a reduced acquisition time that leads to very low photon counts; and 2) imaging in a highly attenuating environment (such as a turbid medium), which makes the reflectivity estimation more difficult at increasing range. Adopting a Bayesian approach, the Poisson distributed observations are combined with prior distributions about the parameters of interest, to build the joint posterior distribution. More precisely, two Markov random field (MRF) priors enforcing spatial correlations are assigned to the DR images. Under some justified assumptions, the restoration problem (regularized likelihood) reduces to a convex formulation with respect to each of the parameters of interest. This problem is first solved using an adaptive Markov chain Monte Carlo (MCMC) algorithm that approximates the minimum mean square parameter estimators. This algorithm is fully automatic since it adjusts the parameters of the MRFs by maximum marginal likelihood estimation. However, the MCMC-based algorithm exhibits a relatively long computational time. The second algorithm deals with this issue and is based on a coordinate descent algorithm. Results on single-photon depth data from laboratory-based underwater measurements demonstrate the benefit of the proposed strategy that improves the quality of the estimated DR images.