Kim Meredith-Jones

Dr. Kim Meredith-Jones


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2020 in Frontiers in Psychiatry
Verified
Journal Article
Open access
PDF file
CSClaire Smith
Claire Smith
BGBarbara Galland
Barbara Galland
RTRachael Taylor
Rachael Taylor
KMKim Meredith-Jones
Kim Meredith-Jones
Objectives: Our count-scaled algorithm automatically scores sleep across 24 hours to process sleep timing, quantity, and quality. The aim of this study was to validate the algorithm against overnight PSG in children to determine the best site placement for sleep. Methods: 28 children (5–8 years) with no history of sleep disturbance wore two types of accelerometers (ActiGraph GT3X+ and Actical) at two sites (left hip, non-dominant wrist) for 24-h. Data were processed using the count-scaled algorithm. PSG data were collected using an in-home Type 2 device. PSG-actigraphy epoch sensitivity (sleep agreement) and specificity (wake agreement) were determined and sleep outcomes compared for timing (onset and offset), quantity [sleep period time (SPT) and total sleep time (TST)], and quality metrics [sleep efficiency and waking after sleep onset (WASO)]. Results: Overall, sensitivities were high (89.1% to 99.5%) and specificities low (21.1% to 45.7%). Sleep offset was accurately measured by actigraphy, regardless of brand or placement site. By contrast, sleep onset agreed with PSG using hip-positioned but not wrist-positioned devices (difference ActiGraph : PSG 21 min, P < .001; Actical : PSG 14 min, P < .001). The ActiGraph at the wrist accurately detected WASO and sleep efficiency, but under (−34 min, P < .001) and overestimated (5.8%, P < .001) these at the hip. The Actical under- and over-estimated these variables respectively at both sites. Results for TST varied ranging from significant differences to PSG of −26 to 21 min (ActiGraph wrist and hip respectively) and 9 min (ns) to 59 min for Actical (wrist and hip respectively). Conclusion: Overall the count-scaled algorithm produced high sensitivity at the expense of low specificity in comparison with PSG. A best site placement for estimates of all sleep variables could not be determined, but overall the results suggested ActiGraph GT3X+ at the hip may be superior for sleep timing and quantity metrics, whereas the wrist may be superior for sleep quality metrics. Both devices placed at the hip performed well for sleep timing but not for sleep quality. Differences are likely linked to freedom of movement of the wrist vs the trunk (hip) during overnight sleep.

1 April 2011 in Complementary Therapies in Medicine
Verified
Journal Article
Closed access
KMKim Meredith-Jones
Kim Meredith-Jones
DWDebra Waters
Debra Waters
MLMichael Legge
Michael Legge
LJLynnette Jones
Lynnette Jones

26 November 2018 in International Journal of Behavioral Nutrition and Physical Activity
Verified
Journal Article
Open access
PDF file
Rachael TaylorRachael Taylor
Rachael Taylor
JHJillian Haszard
Jillian Haszard
KMKim Meredith-Jones
Kim Meredith-Jones
BGBarbara C. Galland
Barbara C. Galland
AHAnne-Louise Heath
Anne-Louise Heath
BTBarry Taylor
Barry Taylor
New physical activity guidelines for children address all movement behaviors across the 24-h day (physical activity, sedentary behavior, sleep), but how each component relates to body composition when adjusted for the compositional nature of 24-h data is uncertain. To i) describe 24-h movement behaviors from 1 to 5 years of age, ii) determine cross-sectional relationships with body mass index (BMI) z-score, iii) determine whether movement behaviors from 1 to 5 years of age predict body composition and bone health at 5 years. 24-h accelerometry data were collected in 380 children over 5–7 days at 1, 2, 3.5 and 5 years of age to determine the proportion of the day spent: sedentary (including wake after sleep onset), in light (LPA) and moderate-to-vigorous physical activity (MVPA), and asleep (including naps). BMI was determined at each age and a dual-energy x-ray absorptiometry (DXA) scan measured fat mass, bone mineral content (BMC) and bone mineral density (BMD) at 5 years of age. 24-h movement data were transformed into isometric log-ratio co-ordinates for multivariable regression analysis and effect sizes back-transformed. At age 1, children spent 49.6% of the 24-h day asleep, 38.2% sedentary, 12.1% in LPA, and 0.1% in MVPA, with corresponding figures of 44.4, 33.8, 19.8 and 1.9% at 5 years of age. Compositional time use was only related significantly to BMI z-score at 3.5 years in cross-sectional analyses. A 10% increase in mean sleep time (65 min) was associated with a lower BMI z-score (estimated difference, − 0.25; 95% CI, − 0.42 to − 0.08), whereas greater time spent sedentary (10%, 47 min) or in LPA (10%, 29 min) were associated with higher BMI z-scores (0.12 and 0.08 respectively, both p < 0.05). Compositional time use from 1 to 3.5 years was not related to future BMI z-score or percent fat. Although MVPA at 2 and 3.5 years was consistently associated with higher BMD and BMC at 5 years, actual differences were small. Considerable changes in compositional time use occur from 1 to 5 years of age, but there is little association with adiposity. Although early MVPA predicted better bone health, the differences observed had little clinical relevance. ClinicalTrials.gov number NCT00892983 .

11 May 2017 in Nutrients
Verified
Journal Article
Open access
PDF file
BDBrittany Davison
Brittany Davison
PSPouya Saeedi
Pouya Saeedi
KBKatherine Black
Katherine Black
HHHarriet Harrex
Harriet Harrex
JHJillian Haszard
Jillian Haszard
Paula SkidmorePaula Skidmore
Paula Skidmore
Previous research investigating the relationship between parents’ and children’s diets has focused on single foods or nutrients, and not on global diet, which may be more important for good health. The aim of the study was to investigate the relationship between parental diet quality and child dietary patterns. A cross-sectional survey was conducted in 17 primary schools in Dunedin, New Zealand. Information on food consumption and related factors in children and their primary caregiver/parent were collected. Principal component analysis (PCA) was used to investigate dietary patterns in children and diet quality index (DQI) scores were calculated in parents. Relationships between parental DQI and child dietary patterns were examined in 401 child-parent pairs using mixed regression models. PCA generated two patterns; ‘Fruit and Vegetables’ and ‘Snacks’. A one unit higher parental DQI score was associated with a 0.03SD (CI: 0.02, 0.04) lower child ‘Snacks’ score. There was no significant relationship between ‘Fruit and Vegetables’ score and parental diet quality. Higher parental diet quality was associated with a lower dietary pattern score in children that was characterised by a lower consumption frequency of confectionery, chocolate, cakes, biscuits and savoury snacks. These results highlight the importance of parental modelling, in terms of their dietary choices, on the diet of children.

16 April 2024 in International Journal of Behavioral Nutrition and Physical Activity
Verified
Journal Article
Open access
PDF file
KMKim Meredith-Jones
Kim Meredith-Jones
JHJ. J. Haszard
J. J. Haszard
AGA. Graham-DeMello
A. Graham-DeMello
ACA. Campbell
A. Campbell
TST. Stewart
T. Stewart
RTR. W. Taylor
R. W. Taylor
Background: Actigraphy is often used to measure sleep in pediatric populations, despite little confirmatory evidence of the accuracy of existing sleep/wake algorithms. The aim of this study was to determine the performance of 11 sleep algorithms in relation to overnight polysomnography in children and adolescents. Methods: One hundred thirty-seven participants aged 8–16 years wore two Actigraph wGT3X-BT (wrist, waist) and three Axivity AX3 (wrist, back, thigh) accelerometers over 24-h. Gold standard measures of sleep were obtained using polysomnography (PSG; Embletta MPRPG, ST + Proxy and TX Proxy) in the home environment, overnight. Epoch by epoch comparisons of the Sadeh (two algorithms), Cole-Kripke (three algorithms), Tudor-Locke (four algorithms), Count-Scaled (CS), and HDCZA algorithms were undertaken. Mean differences from PSG values were calculated for various sleep outcomes. Results: Overall, sensitivities were high (mean ± SD: 91.8%, ± 5.6%) and specificities moderate (63.8% ± 13.8%), with the HDCZA algorithm performing the best overall in terms of specificity (87.5% ± 1.3%) and accuracy (86.4% ± 0.9%). Sleep outcome measures were more accurately measured by devices worn at the wrist than the hip, thigh or lower back, with the exception of sleep efficiency where the reverse was true. The CS algorithm provided consistently accurate measures of sleep onset: the mean (95%CI) difference at the wrist with Axivity was 2 min (-6; -14,) and the offset was 10 min (5, -19). Several algorithms provided accurate measures of sleep quantity at the wrist, showing differences with PSG of just 1–18 min a night for sleep period time and 5–22 min for total sleep time. Accuracy was generally higher for sleep efficiency than for frequency of night wakings or wake after sleep onset. The CS algorithm was more accurate at assessing sleep period time, with narrower 95% limits of agreement compared to the HDCZA (CS:-165 to 172 min; HDCZA: -212 to 250 min). Conclusion: Although the performance of existing count-based sleep algorithms varies markedly, wrist-worn devices provide more accurate measures of most sleep measures compared to other sites. Overall, the HDZCA algorithm showed the greatest accuracy, although the most appropriate algorithm depends on the sleep measure of focus.

1 January 2011 in International Journal of Behavioral Nutrition and Physical Activity
Verified
Journal Article
Open access
PDF file
Rachael TaylorRachael Taylor
Rachael Taylor
VFVictoria L Farmer
Victoria L Farmer
SCSonya L Cameron
Sonya L Cameron
KMKim Meredith-Jones
Kim Meredith-Jones
SWSheila M Williams
Sheila M Williams
JMJim Mann
Jim Mann
Previous work has suggested that the number of permanent play facilities in school playgrounds and school-based policies on physical activity can influence physical activity in children. However, few comparable studies have used objective measures of physical activity or have had little adjustment for multiple confounders.