Xiaojing Gong

Prof. Dr. Xiaojing Gong


Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2018 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
Yan LiYan Li
Yan Li
RLRiqiang Lin
Riqiang Lin
CLChengbo Liu
Chengbo Liu
JCJianhua Chen
Jianhua Chen
HLHuadong Liu
Huadong Liu
LSLiang Song
Liang Song

15 January 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
HZHuangxuan Zhao
Huangxuan Zhao
NCNingbo Chen
Ningbo Chen
TLTan Li
Tan Li
JZJianhui Zhang
Jianhui Zhang
RLRiqiang Lin
Riqiang Lin
CLChengbo Liu
Chengbo Liu
In this paper, we are proposing a novel motion correction algorithm for high-resolution OR-PAM imaging. Our algorithm combines a modified demons-based tracking approach with a newly developed multi-scale vascular feature matching method to track motion between adjacent B-scan images without needing any reference object. We first applied this algorithm to correct motion artifacts within one three-dimensional (3D) data segment of rat iris obtained with OR-PAM imaging. We then extended the application of this algorithm to correct motions to obtain vasculature imaging in the whole mouse back. In here, we stitched five adjacent 3D data segments (large field-of-view) obtained while changing the focus of OR-PAM differently for each subarea. The results showed that the motion artifacts of both large blood vessels and microvessels could be accurately corrected in both cases. Compared to the manually stitching method and the traditional SIFT algorithm, the algorithm proposed in this paper has better performance in stitching adjacent data segments. The high accuracy of the motion correction algorithm makes it valuable in OR-PAM for high-resolution imaging of large animals and for quantitative functional imaging.

16 December 2019 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
HZHuangxuan Zhao
Huangxuan Zhao
ZKZiwen Ke
Ziwen Ke
NCNingbo Chen
Ningbo Chen
SWSongjian Wang
Songjian Wang
KLKe Li
Ke Li
CLChengbo Liu
Chengbo Liu

9 March 2021 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
JLJi Leng
Ji Leng
JZJinke Zhang
Jinke Zhang
CLChenguang Li
Chenguang Li
CSChengyou Shu
Chengyou Shu
BWBoquan Wang
Boquan Wang
LSLiang Song
Liang Song
Myocardial infarctions are most often caused by the so-called vulnerable plaques, usually featured as non-obstructive lesions with a lipid-rich necrotic core, thin-cap fibroatheroma, and large plaque size. The identification and quantification of these characteristics are the keys to evaluate plaque vulnerability. However, single modality intravascular methods, such as intravascular ultrasound, optical coherence tomography and photoacoustic, can hardly achieve all the comprehensive information to satisfy clinical needs. In this paper, for the first time, we developed a novel multi-spectral intravascular tri-modality (MS-IVTM) imaging system, which can perform 360° continuous rotation and pull-backing with a 0.9-mm miniature catheter and achieve simultaneous acquisition of both morphological characteristics and pathological compositions. Intravascular tri-modality imaging demonstrates the ability of our MS-IVTM system to provide macroscopic and microscopic structural information of the vessel wall, with identity and quantification of lipids with multi-wavelength excitation. This study offers clinicians and researchers a novel imaging tool to facilitate the accurate diagnosis of vulnerable atherosclerotic plaques. It also has the potential of clinical translations to help better identify and evaluate high-risk plaques during coronary interventions.

1 December 2020 in Photoacoustics
Verified
Journal Article
Open access
MSMingjian Sun
Mingjian Sun
CLChao Li
Chao Li
NCNingbo Chen
Ningbo Chen
HZHuangxuan Zhao
Huangxuan Zhao
LMLiyong Ma
Liyong Ma
XGXiaojing Gong
Xiaojing Gong
Quantitative analysis of tumor vessels is of great significance for tumor staging and diagnosis. Photoacoustic imaging (PAI) has been proven to be an effective way to visualize comprehensive tumor vascular networks in three-dimensional (3D) volume, while previous studies only quantified the vessels projected in one plane. In this study, tumor vessels were segmented and quantified in a full 3D framework. It had been verified in the phantom experiments that the 3D quantification results have better accuracy than 2D. Furthermore, in vivo vessel images were quantified by 2D and 3D quantification methods respectively. And the difference between these two results is significant. In this study, complete vessel segmentation and quantification method within a 3D framework was implemented, which showed obvious advantage in the analysis accuracy of 3D photoacoustic images, and potentially improve tumor study and diagnosis.

27 October 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
ZXZhihua Xie
Zhihua Xie
CSChengyou Shu
Chengyou Shu
DYDaya Yang
Daya Yang
HCHao Chen
Hao Chen
CCChaobin Chen
Chaobin Chen
XGXiaojing Gong
Xiaojing Gong
Intravascular photoacoustic (IVPA) imaging technology enables the visualization of pathological characteristics (such as inflammation activities, lipid deposition) of the artery wall. Blood flushing is a necessary step in improving the imaging quality in in vivo IVPA imaging. But the limited imaging speed of the systems stretches their flushing time, which is an important obstacle of their clinical translations. In this paper, we report an improvement in IVPA/IVUS imaging speed to 100 frames per second. The high-speed imaging is demonstrated in rabbit in vivo, visualizing the nanoparticles accumulated on abdominal aorta wall at the wavelength of 1064 nm, in real time display. Blood flushing in vivo improves the IVPA signal-noise-ratio by around 3.5 dB. This study offers a stable, efficient and easy-to-use tool for instantaneous disease visualization and disease diagnosis in research and forwards IVPA/IVUS imaging technology towards clinical translations.