Mohammad Reza Jamalpour

Dr. Mohammad Reza Jamalpour


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2014 in Journal of Trauma and Acute Care Surgery
Verified
Journal Article
Closed access
MMMohammad Hosein Kalantar Motamedi
Mohammad Hosein Kalantar Motamedi
EDEsmaeel Dadgar
Esmaeel Dadgar
AEAli Ebrahimi
Ali Ebrahimi
GSGholamreza Shirani
Gholamreza Shirani
AHAbbas Haghighat
Abbas Haghighat
MJMohammad Reza Jamalpour
Mohammad Reza Jamalpour
This multicenter study assessed the demographics, prevalence, causes, types, treatment, and complications of maxillofacial (MF) fractures managed by MF surgeons nationwide. This 5-year retrospective descriptive analytical chart study evaluated 8,818 patients treated for MF fractures from 2007 to 2012 at 11 medical centers. Parameters, including age, sex, cause of injury, site of injury, type of injury, fracture patterns, treatment modalities, and complications, were evaluated from patient charts and radiographs. Collected data were analyzed via t test or χ test using SPSS 20 (Chicago, IL). A p value of less than 0.05 was considered statistically significant. This retrospective chart study was exempt from institutional review board approval. There were 7,369 male patients (83.6%), 1,376 female patients (15.7%), and 73 patients (0.8%) of unknown sex (aged 6 months to 112 years); 39.54% (3,457 patients) were in the 21-year to 30-year age group (mean, 28.18 years). We found 5,737 mandibular fractures (65.1%); mandible fracture was the most common (p < 0.05), followed by maxillary (1,641, 18.6%), zygomatic (3,240, 36.0%), orbital floor (743, 8.4%), naso-orbitoethmoidal (472, 5.4%), nasal (848, 9.6%), and frontal (344, 3.9%) fractures. Road traffic accidents were the most common cause. Posttreatment documented complications included remaining neurosensory disturbance of the inferior alveolar nerve (16.01%) and the infraorbital nerve (15.5%), remaining neuromotor disturbance of the facial nerve (2.3%), blurred vision (2.43%), diplopia (3.2%), limitation of eye movement (1.6%), exophthalmoses (1.88%), blindness (0.8%), as well as postoperative infection and chronic osteomyelitis (1.0%). On the basis of our study, mandibular fractures, in males and resulting from road traffic accidents in the third decade of life, were significant findings. Although the prevalence of MF fractures, demographics, and causes vary from one country to another and awareness of these patterns can provide insight to prevention protocols, this study shows that, despite better law enforcement of traffic regulations, better roads, better automobiles, and the like, the pattern of MF fractures in Iran has not changed significantly during the past 10 years. Epidemiologic study, level IV.

3 September 2022 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
ASAbbas Shokri
Abbas Shokri
FVFariborz Vafaee
Fariborz Vafaee
LHLeila Haghighat
Leila Haghighat
SSShiva Shahabi
Shiva Shahabi
MFMaryam Farhadian
Maryam Farhadian
MJMohammad Reza Jamalpour
Mohammad Reza Jamalpour
Background: This study aimed to compare the amount of artifacts induced by the titanium and zirconium implants on cone-beam computed tomography (CBCT) and assess the effect of different exposure settings on the image quality for both materials. Methods: In this experimental study, 30 zirconium and 30 titanium implants were placed in bovine rib bone blocks. CBCT images were taken in two different fields of view (FOV: 4 × 6 cm2 and 6 × 8 cm2) and at two resolutions (133 µ and 200 µ voxel size). Subsequently, two observers assessed the images and detected the amount of artifacts around the implants through gray values. Data were analyzed by paired t test and independent t test using SPSS 21 and the 0.05 significance level. Results: The results showed that titanium implants caused lower amounts of artifacts than zirconium implants, which was statistically significant (P < 0.001). The larger FOV (6 × 8 cm2) resulted in a lower amount of artifacts in both groups, although the results were only statistically significant in the zirconium group (P < 0.001). The amount of artifacts was increased when using the 133 µ voxel size in both groups, which was only significant in the zirconium group (P < 0.001). Conclusion: Our results suggest that zirconium implants induce higher amounts of artifacts than titanium ones. We also concluded that the artifacts could be minimized using the larger FOV and voxel size.

25 June 2013 in Avicenna Journal of Dental Research
Verified
Journal Article
Open access
PDF file
MJMohammad Reza Jamalpour
Mohammad Reza Jamalpour
ITIde Talimkhani
Ide Talimkhani
Background: In spite of common usage of the inferior alveolar nerve block (IANB), this method has some well-defined restrictions. Objectives: The purpose of the present study was to compare these two techniques for the surgical removal of impacted lower third molars. Patients and Methods: A total of 44 similarly impacted lower third molars (22 patients with two similar teeth) were selected. In each patient, one side was anesthetized with the Gow-Gates technique and another side with the IANB, randomly. The number of injections for achieving anesthesia, incidence of pain during injections, and the supplementary injections during surgery were recorded for each side Results: In Gow-Gates technique, less repetition of injection was required to achieve anesthesia as well as less supplementary injections during surgery; however, these differences were not significant statistically (P = 0.39, P = 0.11). The pain during Gow-Gates injections was significantly shorter than that of the IANB (P = 0.007). Conclusions: Even though the patients felt less pain during the Gow-Gates injection, this technique has no advantage over the IANB during surgical removal of impacted lower third molar. Keywords: Local Anesthesia; Mandibular Nerve Block; Inferior Alveolar Nerve

1 July 2019 in Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
ITIdeh Talimkhani
Ideh Talimkhani
MJMohammad Reza Jamalpour
Mohammad Reza Jamalpour
HBHamed Babaei
Hamed Babaei
JFJavad Faradmal
Javad Faradmal

17 July 2025 in Photodiagnosis and Photodynamic Therapy
Verified
Journal Article
Open access
MJMohammad Reza Jamalpour
Mohammad Reza Jamalpour
HAHanieh Tavassoli Ara
Hanieh Tavassoli Ara
FSFatemeh Sheibani
Fatemeh Sheibani
PAPantea Amiri
Pantea Amiri
Reza FekrazadReza Fekrazad
Reza Fekrazad
Rhinoplasty, while effective for nasal reshaping, frequently results in postoperative edema and delayed recovery. This randomized controlled trial evaluated photobiomodulation (PBM) using a 940 nm diode laser (4 J/cm² energy density, 0.1 W power, 2.27 cm² spot size) for managing nasal swelling in 20 patients following open rhinoplasty. Participants were allocated to laser (16 sessions over 8 weeks) or control groups, with standardized photogrammetric measurements of nasal width and tip rotation preoperatively and at 1, 4, and 8 weeks postoperatively. The intervention group demonstrated a mean nasal width reduction of 2.5 mm (p = 0.08) and a 3-degree improvement in tip rotation (p = 0.12) compared to controls, though statistical significance was not achieved. Qualitative assessments revealed marked edema reduction in 70 % of treated patients versus 30 % of controls. While limited by sample size, these findings suggest 940 nm PBM may accelerate resolution of post-rhinoplasty swelling through anti-inflammatory mechanisms, warranting further investigation in larger cohorts.

9 August 2022
Verified
Journal Article
Open access
PDF file
MJMohammad Reza Jamalpour
Mohammad Reza Jamalpour
HBHamed Babaei
Hamed Babaei
NKNasrin Shirmohamadi Khoram
Nasrin Shirmohamadi Khoram
Background and Objective: Hump reduction is performed by different instruments with inherent drawbacks. The present study was conducted to compare the frequency of complications in the nasal bridge area after hump reduction with piezosurgery and a conventional instrument (Rasp). Materials and Methods: This clinical trial was carried out on 20 primary rhinoplasty patients. The patients were randomly assigned to two groups. In one group, nasal dorsum height reduction was performed with a rasp, and in the other group, hump reduction was fulfilled with piezosurgery. The patients in both groups were examined after 10, 30, and 90 days of surgery to detect palpebral ecchymosis, asymmetry, bony form, and cartilaginous irregularities of the dorsum. Results: In the rasp group, two patients with ecchymosis were observed on the 10th day after surgery. Moreover, one patient with dorsal asymmetry, two patients with bony form, and one patient with cartilaginous irregularity in the dorsum were observed in the 3rd month after surgery. In the piezosurgery group, no patient had any complications. However, these differences between the two groups were not statistically significant (P>0.05). Conclusion: As evidenced by the obtained results, piezosurgery can be used safely for hump reduction.