Tohru Hayakawa

Prof. Tohru Hayakawa


Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in BioMed Research International
Verified
Journal Article
Open access
PDF file
YKYou Kusakawa
You Kusakawa
EYEiji Yoshida
Eiji Yoshida
THTohru Hayakawa
Tohru Hayakawa
Protein adsorption onto titanium (Ti) or zirconia (ZrO2) was evaluated using a 27 MHz quartz crystal microbalance (QCM). As proteins, fibronectin (Fn), a cell adhesive protein, and albumin (Alb), a cell adhesion-inhibiting protein, were evaluated. The Ti and ZrO2sensors for QCM were characterized by atomic force microscopy and electron probe microanalysis observation, measurement of contact angle against water, and surface roughness. The amounts of Fn and Alb adsorbed onto the Ti and ZrO2sensors and apparent reaction rate were obtained using QCM measurements. Ti sensor showed greater adsorption of Fn and Alb than the ZrO2sensor. In addition, amount of Fn adsorbed onto the Ti or ZrO2sensors was higher than that of Alb. The surface roughness and hydrophilicity of Ti or ZrO2may influence the adsorption of Fn or Alb. With regard to the adsorption rate, Alb adsorbed more rapidly than Fn onto Ti. Comparing Ti and ZrO2, Alb adsorption rate to Ti was faster than that to ZrO2. Fn adsorption will be effective for cell activities, but Alb adsorption will not. QCM method could simulatein vivoFn and Alb adsorption to Ti or ZrO2.

25 May 2018 in Materials
Verified
Journal Article
Open access
PDF file
AKAkira Kuroiwa
Akira Kuroiwa
Yoshiaki NomuraYoshiaki Nomura
Yoshiaki Nomura
Tsuyoshi OchiaiTsuyoshi Ochiai
Tsuyoshi Ochiai
TSTomomi Sudo
Tomomi Sudo
RNRie Nomoto
Rie Nomoto
NHNobuhiro Hanada
Nobuhiro Hanada
Photocatalysts have multiple applications in air purifiers, paints, and self-cleaning coatings for medical devices such as catheters, as well as in the elimination of xenobiotics. In this study, a coating of a UV-responsive photocatalyst, titanium dioxide (TiO2), was applied to an orthodontic resin. The antibacterial activity on oral bacteria as well as hydrophilic properties and mechanical properties of the TiO2-coated resin were investigated. ultraviolet A (UVA) (352 nm) light was used as the light source. Antibacterial activity was examined with or without irradiation. Measurements of early colonizers and cariogenic bacterial count, i.e., colony forming units (CFU), were performed after irradiation for different time durations. Hydrophilic properties were evaluated by water contact angle measurements. While, for the assessment of mechanical properties, flexural strength was measured by the three-point bending test. In the coat(+)light(+) samples the CFU were markedly decreased compared to the control samples. Water contact angle of the coat(+)light(+) samples was decreased after irradiation. The flexural strength of the specimen irradiated for long time showed a higher value than the required standard value, indicating that the effect of irradiation was weak. We suggest that coating with the ultraviolet responsive photocatalyst TiO2 is useful for the development of orthodontic resin with antimicrobial properties.

9 August 2017 in Materials
Verified
Journal Article
Open access
PDF file
YTYoshifumi Tada
Yoshifumi Tada
THTohru Hayakawa
Tohru Hayakawa
YNYoshiki Nakamura
Yoshiki Nakamura
Polyetheretherketone (PEEK) is now attracting attention as an alternative to metal alloys in the dental field. In the present study, we evaluated the load-deflection characteristics of PEEK wires in addition to their frictional properties. Three types of PEEK wires are used: two sizes of rectangular shape, 0.016 × 0.022 in2 and 0.019 × 0.025 in2 (19-25PEEK), and rounded shape, diameter 0.016 in (16PEEK). As a control, Ni-Ti orthodontic wire, diameter 0.016 in, was used. The three-point bending properties were evaluated in a modified three-point bending system for orthodontics. The static friction between the orthodontic wire and the bracket was also measured. The load-deflection curves were similar among Ni-Ti and PEEK wires, except for 16PEEK with slot-lid ligation. The bending force of 19-25PEEK wire was comparable with that of Ni-Ti wire. 19-25PEEK showed the highest load at the deflection of 1500 μm (p < 0.05) in the case of slot-lid ligation. No significant differences were seen in the permanent deformation between Ni-Ti and all three PEEK wires (p > 0.05). No significant difference was seen in static friction between all three PEEK wires and Ni-Ti wire (p > 0.05). It is suggested that 19-25PEEK will be applicable for orthodontic treatment with the use of slot-lid ligation.

19 December 2019 in Materials
Verified
Journal Article
Open access
PDF file
YIYohei Iinuma
Yohei Iinuma
MHMasatsugu Hirota
Masatsugu Hirota
THTohru Hayakawa
Tohru Hayakawa
COChikahiro Ohkubo
Chikahiro Ohkubo
Yttria-stabilized tetragonal zirconia polycrystals (Y-TZP), which are partially stabilized zirconia, have been used for fabricating dental implants. This study investigated the soft tissue attachment, the collagen fiber orientation to zirconia at different surface conditions, and the bone response using implantation experiments in animals. The zirconia implant surfaces were treated with ultraviolet irradiation (UV), a combination of large-grit sandblasting and hydrofluoric acid etching (blastedHF), and a combination of blastedHF and UV (blastedHF+UV). The surface treated with blastedHF and blastedHF+UV appeared rough and hydrophilic. The surface treated with blastedHF+UV appeared to be superhydrophilic. Subsequently, tapered cylindrical zirconia implants were placed in the alveolar sockets of the maxillary molars of rats. The bone-to-implant contact ratio of blastedHF and blastedHF+UV implants was significantly higher than that of the non-treated controls and UV-treated implants. The four different surface-treated zirconia implants demonstrated tight soft tissue attachments. Perpendicularly oriented collagen fibers towards zirconia implants were more prominent in blastedHF and blastedHF+UV implants compared to the controls and UV-treated implants. The area of the soft tissue attachment was the greatest with the perpendicularly oriented collagen fibers of blastedHF+UV-treated implants. In conclusion, blastedHF+UV treatment could be beneficial for ensuring greater soft-tissue attachment for zirconia implants.

1 January 2017 in Dental Materials Journal
Verified
Journal Article
Open access
PDF file
KNKeiko Nitta
Keiko Nitta
RNRie Nomoto
Rie Nomoto
YTYuji Tsubota
Yuji Tsubota
MTMasuji Tsuchikawa
Masuji Tsuchikawa
THTohru Hayakawa
Tohru Hayakawa
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies

1 November 1992 in Dental Materials
Verified
Journal Article
Closed access
THTohru Hayakawa
Tohru Hayakawa
KHK. Horie
K. Horie