Boonchai Techaumnat

Dr. Boonchai Techaumnat

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2008 in IET Nanobiotechnology
Verified
Journal Article
Closed access
BTBoonchai Techaumnat
Boonchai Techaumnat
KTK. Tsuda
K. Tsuda
OKO. Kurosawa
O. Kurosawa
GMG. Murat
G. Murat
HOH. Oana
H. Oana
MWM. Washizu
M. Washizu
The authors present the use of electric-field constriction created by a microfabricated structure to realise high-yield electrofusion of biological cells. The method uses an orifice on an electrically insulating wall (orifice plate) whose diameter is as small as that of the cells. Owing to the field constriction created by the orifice, we can induce the controlled magnitude of membrane voltage selectively around the contact point, regardless of the cell size. The field constriction also ensures 1:1 fusion even when more than two cells are forming a chain at the orifice. A device for electrofusion has been made with a standard SU-8 lithography and PDMS molding, and real-time observation of the electrofusion process is made. Experiments using plant protoplasts or mammalian cells show that the process is highly reproducible, and the yield higher than 90% is achieved.

1 March 2006 in Journal of Electrostatics
Verified
Journal Article
Closed access
BTBoonchai Techaumnat
Boonchai Techaumnat
TTTadasu Takuma
Tadasu Takuma

31 August 2011 in Journal of Electrostatics
Verified
Journal Article
Closed access
BTBoonchai Techaumnat
Boonchai Techaumnat
MWM. Washizu
M. Washizu

4 September 2008 in IET Nanobiotechnology
Verified
Journal Article
Closed access
MWM. Washizu
M. Washizu
BTBoonchai Techaumnat
Boonchai Techaumnat
The estimation of the membrane voltage and the polarisation factor of biological cells provide a base for the study of bio-manipulation techniques, such as dielectrophoresis, electroporation or electrofusion. To model a biological cell, an ellipsoidal particle with an insulating membrane is sometimes employed, but due to the limitation of the confocal nature of the coordinate system, the membrane thickness is assumed to vary with the position, despite the fact that the lipid bilayer membrane has a uniform thickness. The authors present a method to rigorously treat the uniform-thickness condition in a system having an axial symmetry. The method is based on the harmonic expansion of the field, to include the condition of the uniform-membrane thickness as a series expansion of the geometrical factor, and to solve the field problem as an interaction of the harmonic components. The conventional variable thickness model has been identified as being equivalent to neglecting the harmonic interactions in the uniform-thickness model. Numerical calculations are done of the membrane voltage and the polarisation factor, and it has been found that the discrepancy between the proposed rigorous model and the conventional variable thickness model becomes significant when field deformation is large due to the high axial ratio of the ellipsoid.

12 June 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KMKhanit MATRA
Khanit MATRA
PBPattakorn Buppan
Pattakorn Buppan
BTBoonchai Techaumnat
Boonchai Techaumnat
The paper investigated studies on the application of pulsed electric fields for the treatment of liquid media in a continuous manner in a co-field treatment chamber with elliptic insulator profiles. The electric field distribution and the temperature rise in the treatment chamber were evaluated via the finite element method. A non-uniform electric field was found at the elliptical insulator edges, while the electric field distribution on the insulator surface was rather uniform. The maximum temperature rise in the liquid media was located slightly behind the elliptic insulator due to the accumulated heat in the flowing liquid media. In the optimized treatment chamber, the average electric field intensity could be as high as 12.21 kV/cm at the moderate voltage at 7.5 kV. As a strategy to improve the inactivation while limiting the temperature rise, a series of treatment chambers was verified by experiments under the conditions of 7.5 kV, a 2.5% duty cycle, and 250 Hz. It was found that an increase in the treatment units could increase the inactivation efficiency for Escherichia coli. The average log reduction could be improved from 1.82 to 2.39 when the number of treatment units was increased from 1 to 5, respectively.

26 April 2022 in Electrophoresis
Verified
Journal Article
Closed access
NPNitipong Panklang
Nitipong Panklang
BTBoonchai Techaumnat
Boonchai Techaumnat
AWAnurat Wisitsoraat
Anurat Wisitsoraat
CPChaturong Putaporntip
Chaturong Putaporntip
KCKesinee Chotivanich
Kesinee Chotivanich
YSYuji Suzuki
Yuji Suzuki