Martin Zálešák

Dr. Martin Zálešák


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2018 in Energies
Verified
Journal Article
Open access
PDF file
Hana CharvatovaHana Charvatova
Hana Charvatova
Ales ProchazkaAles Prochazka
Ales Prochazka
MZMartin Zálešák
Martin Zálešák
This paper is devoted to modelling of temperature distribution and its time evolution in rooms with specific thermal insulation and heat transfer for different external conditions. The simulation results should help to design the room architecture and wall materials to reduce energy losses due to heating or cooling, and to increase the inside thermal comfort. For this purpose, a methodological procedure using real data processing in the COMSOL Multiphysics modelling environment and spatial visualization of temperature evolution is proposed. This paper describes a mathematical model for simulation of the temperature evolution inside a space with thermally insulated walls under selected outside conditions. Computer simulations are then used to assess the temperature distribution inside the room and the heat flow through the room walls. Results of the simulations are used for subsequent determination of the time needed for the desired decrease of air temperature inside the tested room during its cooling due to the low ambient temperature, which is related to the thermal stability of the building, specific heat capacity, and thickness of the thermal insulation. Under the studied conditions, the time to reach the temperature drops by 20 percent in a room with windows was from 1.4 to 1.8 times lower than that in the room without windows. The proposed methodology shows the flexibility of computer modelling in the design of insulated building systems. The mesh density testing was performed by comparing the air temperature evolution in the model of the selected mesh density and the model with its maximum value enabled by the size of computer memory. The maximum temperature deviation calculated for the mesh of the presented model was 0.57%.

28 September 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JSJan Skovajsa
Jan Skovajsa
MZMartin Zálešák
Martin Zálešák
The article is focused on the research of the usage of modern accumulation technology. The proposed system is able to improve the thermal comfort of building interiors. That text depicts the technology, which uses a photovoltaics and other renewable energy sources for active heating and cooling. The bases of the presented technology are the phase change material and thermal energy storages. So, it passively improves the thermal capacity of the constructions of the buildings. Moreover, there is a possibility to use it for active heating and cooling. The technology contains thermoelectric assemblies, so, there is a very interesting possibility to store thermal energy with use of renewable energy sources (such as photovoltaic system) and thermoelectric coolers side by side. In the manuscript, there are shown measurements and results of the active operating modes of proposed technology. It was found the technology is able to work in active heating and cooling modes. It works quite well in active heating mode. On the other hand, thermoelectric cooling mode had a problem with overheating. In the end, the problem was solved and the cooling mode works. The measurements and results are described in the text.

19 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
Hana CharvatovaHana Charvatova
Hana Charvatova
Ales ProchazkaAles Prochazka
Ales Prochazka
MZMartin Zálešák
Martin Zálešák
The paper is devoted to computer simulations of the distribution and time evolution of the temperature in a wooden house in summer. The goal of simulations was to assess the effect of covering walls inside the house with a PCM (phase change material) on its passive cooling, which prevents the undesired overheating of the house and provides the required thermal comfort for the occupants under warm summer days. Computer simulations were performed by the COMSOL Multiphysics software (COMSOL Inc., Stockholm, Sweden). A model of a house without the PCM coverage was compared with models of houses in which the PCM was located on all walls, except a floor, and on a wall opposite the window. Results of simulations proved that the wood wall thickness and PCMs location influence overheating the wooden house. Under studied conditions, the coverage of a wall opposite the window best eliminated extremes of the air temperature inside the house. The maximum temperature decrease was 3.9 °C (i.e., drop of 31.1%) comparing the house which wall opposite the window was covered by the PCM and the house without the PCM coverage.

5 October 2018 in MATEC Web of Conferences
Verified
Journal Article
Open access
Hana CharvatovaHana Charvatova
Hana Charvatova
MZMartin Zálešák
Martin Zálešák
The paper deals with computer testing of the temperature distribution in buildings by using COMSOL Multiphysics software. It is devoted to a description of a computer application created in the Application Builder user interface for simulation of the temperature distribution in a room heated by two heat sources. The application allows you to change geometric dimensions of all elements of the studied model and their spatial distribution, as well as a choice of physical properties needed to access the distribution of temperature in the room depending on the ambient temperature and the heat input of the considered sources. Main functions of the application are presented by simulation of cyclic heating and cooling of the tested room.

18 November 2020 in MATEC Web of Conferences
Verified
Journal Article
Open access
PDF file
SSStanislav Sehnalek
Stanislav Sehnalek
MZMartin Zálešák
Martin Zálešák
This article describing newly build tract for measuring regenerative heat exchangers. At the beginning of this work is summarised measuring of heat recovery exchangers, parameters of heat recovery exchangers and conditions of measurements. This article continuous with the introduction of HVAC laboratory for which new track is built. Particular emphasis is on measuring box in which are exchangers measured.

22 September 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Hana CharvatovaHana Charvatova
Hana Charvatova
Ales ProchazkaAles Prochazka
Ales Prochazka
MZMartin Zálešák
Martin Zálešák
VMVladimír Mařík
Vladimír Mařík
The integration of electric underfloor heating systems with photovoltaic (PV) panels presents a promising approach to enhance thermal efficiency and energy sustainability in residential heating. This study investigates the performance of such hybrid systems under different energy supply scenarios. Numerical modeling and simulations were employed to evaluate underfloor heating performance using three electricity sources: standard electric supply, solar-generated energy, and a combined configuration. Solar irradiance sensors were utilized to collect input solar radiation data, which served as a critical parameter for numerical modeling and simulations. The set outdoor air temperature used in the analysis represents an average value calculated from data measured by environmental sensors at the location of the building during the monitored period. Key metrics included indoor air temperature, time to thermal stability, and heat loss relative to outdoor conditions. The combined electric and solar-powered system demonstrated thermal efficiency, improving indoor air temperature by up to 63.6% compared to an unheated room and achieving thermal stability within 22 h. Solar-only configuration showed moderate improvements. Heat loss analysis revealed a strong correlation with indoor–outdoor temperature differentials. Hybrid underfloor heating systems integrating PV panels significantly enhance indoor thermal comfort and energy efficiency. These findings support the adoption of renewable energy technologies in residential heating, contributing to sustainable energy transitions.