Implant-associated osteomyelitis is one of the most feared complications following orthopedic surgery. Although the risk is low, sufficient antibiotic protection of the implant surface is important. The aim of this study was to assess steady-state piperacillin concentrations in the proximity of an orthopedic implant. Time above the minimal inhibitory concentration (fT>MIC) was evaluated for MIC of 8 (low target) and 16 μg/mL (high target). Six female pigs received an intravenous bolus infusion of 4 g/0.5 g piperacillin/tazobactam over 30 min every 6 h. Steady state was assumed achieved in the third dosing interval (12–18 h). Microdialysis catheters were placed in a cannulated screw in the proximal tibial cancellous bone, in cancellous bone next to the screw, and in cancellous bone on the contralateral tibia. Dialysates were collected from time 12 to 18 h and plasma samples were collected as reference. For the low piperacillin target (8 µg/mL), comparable mean fT>MIC across all the investigated compartments (mean range: 54–74%) was found. For the high target (16 µg/mL), fT>MIC was shorter inside the cannulated screw (mean: 16%) than in the cancellous bone next to the screw and plasma (mean range: 49–54%), and similar between the two cancellous bone compartments. To reach more aggressive piperacillin fT>MIC targets in relation to the implant, alternative dosing regimens such as continuous infusion may be considered.
26 October 2024 in Journal of Experimental Orthopaedics
Purpose: Documentation of the wrist stabilizing effect and mechanical properties of common splinting materials is warranted to support evidence‐based condition‐specific recommendations for wrist immobilization. The objectives of this study were to assess the wrist stabilizing properties of volar and dorsal short‐arm splints made of four different materials and evaluate the mechanical properties of the splinting materials.Methods: Dorsal and volar short arm splints made of plaster of Paris (PoP) (eight layers), Woodcast (2 mm, rigid vented), X‐lite (classic, two layers) or a 3D‐printed material (polypropylene) were sequentially mounted on 10 cadaveric arm specimens and fixed in a radiolucent fixture. This enabled the evaluation of maximum wrist flexion and extension relative under an orthogonal load of 42 N via radiographic images. In addition, a three‐point bending test was performed on ten sheet duplicates of each of the four splinting materials.Results: When applied as a volar splint, PoP had the highest capability to resist wrist flexion and extension. However, when applied as a dorsal splint, Woodcast exhibited a lower wrist flexion and a similar wrist extension. The 3D‐printed splints—both volar and dorsal—showed the highest mean wrist flexion and extension. The mechanical properties of the Woodcast, X‐lite and 3D‐printed splinting materials were very similar. PoP exhibited distinct properties with a stiffness of 146 (95% confidence interval [CI]: 120–173) N/mm and a deflection at Fmax of 0.6 (95% CI: 0.5–0.7) mm compared to ≤7.7 (95% CI: 7.4–7.9) N/mm and ≥20 (95% CI: 18–22) mm for the other materials.Conclusion: PoP displayed better wrist stabilizing properties and material stiffness than Woodcast, X‐lite and 3D‐printed polypropylene. When considering wrist stabilizing properties, PoP may still prove to be the preferred choice for wrist immobilization.Level of Evidence: Not applicable.
Microdialysis is a catheter-based method suitable for dynamic sampling of unbound antibiotic concentrations. Intravenous antibiotic concentration sampling by microdialysis has several advantages and may be a superior alternative to standard plasma sampling. We aimed to compare concentrations obtained by continuous intravenous microdialysis sampling and by standard plasma sampling of both vancomycin and meropenem in a porcine model. Eight female pigs received 1 g of both vancomycin and meropenem, simultaneously over 100 and 10 min, respectively. Prior to drug infusion, an intravenous microdialysis catheter was placed in the subclavian vein. Microdialysates were collected for 8 h. From a central venous catheter, plasma samples were collected in the middle of every dialysate sampling interval. A higher area under the concentration/time curve and peak drug concentration were found in standard plasma samples compared to intravenous microdialysis samples, for both vancomycin and meropenem. Both vancomycin and meropenem concentrations obtained with intravenous microdialysis were generally lower than from standard plasma sampling. The differences in key pharmacokinetic parameters between the two sampling techniques underline the importance of further investigations to find the most suitable and reliable method for continuous intravenous antibiotic concentration sampling.