The electric energy demand of data centers in Germany has grown rapidly from 10.5 TWh/a in 2010 to 13.2 TWh/a in 2017, an average of 25% of which are used to fulfill the data centers' cooling demand. In order to increase its energy efficiency, TU Darmstadt applies a new cooling concept in the next generation of its high‐performance computing data center “Lichtenberg II.” Instead of the current air‐cooled servers with water‐cooled rear doors at 17‐24°C, the new data center will be equipped with direct hot‐water cooling for the high‐performance computer, supplying heat at a temperature of 45°C. The high‐temperature waste heat is used for heating purposes on the university's campus Lichtwiese. For waste heat utilization, two concepts are presented, either integrating the heat in the return line of the district heating network or using it locally in buildings located near the data center. Reductions in CO2 emission and annuity are generated both by decreased compression cooling demand for the data center and by decreased heat generation due to waste heat utilization. Depending on the scenario, a total of 20%‐50% of the waste heat emitted by the high‐performance computer can be used for heating purposes, while the remaining heat is dissipated efficiently via free cooling without additional energy demand for mechanical chillers. CO2 emission can be decreased by up to 720 , representing a reduction of about 4% of the total emission at campus Lichtwiese. TU Darmstadt is currently implementing the waste heat integration into its district heating network and will benefit from this concept starting in 2020.
We analyze entanglement in the family of translationally invariant matrix product states (MPS). We give a criterion to determine when two states can be transformed into each other by local operations with a nonvanishing probability, a central question in entanglement theory. This induces a classification within this family of states, which we explicitly carry out for the simplest, nontrivial MPS. We also characterize all symmetries of translationally invariant MPS, both global and local (inhomogeneous). We illustrate our results with examples of states that are relevant in different physical contexts.
Simon Morelli, David Sauerwein, Michalis Skotiniotis, and Nicolai Friis, Quantum 6, 722 (2022). We consider the distribution of high-dimensional entangled states to multiple parties via noisy channels and the subsequent probabilistic conversion of these states to desired target states…
We determine the local symmetries and local transformation properties of certain many-body states called translationally invariant matrix product states (TIMPSs). We focus on physical dimension of the local Hilbert spaces and bond dimension and use the procedure introduced in Sauerwein et al. [ Phys. Rev. Lett. 123, 170504 (2019)] to determine all (including nonglobal) symmetries of those states. We identify and classify the stochastic local operations assisted by classical communication (SLOCC) that are allowed among TIMPSs. We scrutinize two very distinct sets of TIMPSs and show the big diversity (also compared to the case ) occurring in both their symmetries and the possible SLOCC transformations. These results reflect the variety of local properties of MPSs, even if restricted to translationally invariant states with low bond dimension. Finally, we show that states with nontrivial local symmetries are of measure zero for and .
Lowering the temperatures in heating systems is the key to decarbonizing the heat supply in the building sector, because it is a door opener to greater integration of renewable heat, the use of excess heat and to improve compatibility for heat pumps. This often fails because heating systems, especially in unrenovated building stock, usually require high supply temperatures. Previous studies on temperature reduction in existing buildings are performed mainly numerically, whereas in this research the numeric calculations are validated by measurements. For this purpose, a demonstrator with two different ceiling heating systems is integrated in the listed architecture building of the Technical University of Darmstadt and the achievable temperature reduction is investigated. Based on this, parameter variations are conducted through a simulation model in order to test the feasibility of the concept for the entire building. The results show that even with an unrenovated building envelope, a significant temperature reduction to below 45 °C is possible without exceeding the normative limits of thermal comfort. With moderate building envelope renovation, the reduction is possible even to below 36 °C. The measures investigated can make the building compatible with renewable heat potentials without negative impacts on the cultural heritage.