This paper introduces an analog notch filtering-based coupling circuit for receivers in ultra-narrowband and narrowband power line communication systems, which are connected to low-voltage electric power grids. It is composed of a twin-T notch analog filter, which is responsible for imposing a significant attenuation on the main frequency (i.e., Hz) in cascade with an elliptic low-pass analog filter, designed with a 3 dB cut-off frequency of . For Hz and MHz, the prototype of the analog notch filtering-based coupling circuit attains attenuation values of 22 dB and less than 2 dB at the main frequency and in the rest of the frequency bandwidth, respectively, when practical scenarios are considered. Lastly, it shows that the analog notch filtering-based coupling circuit is more effective than a typical capacitive coupling circuit when frequencies lower than 3 kHz are considered for data communication and sensing purposes.
This paper delves into the design of passive analog blocking filters to mitigate conductive emissions and address impedance mismatches, which significantly impair the performance of narrowband power line communication systems. These systems have emerged as pivotal data communication technologies for Internet of Things applications, especially within the electricity sector. Experimental analyses centered on scattering parameters and power spectral density demonstrate that the designed passive analog blocking filter is not only straightforward and cost-effective but also performs satisfactorily when compared to another passive analog blocking filter.
1 January 2024 in Journal of Microwaves, Optoelectronics and Electromagnetic Applications
This study examines the characteristics of the lowvoltage MIMO-PLC electric power line channel, which operates within the 2-100 MHz frequency range. The research involved measurements in four different Setups using 2.5 mm copper wires, including phase, neutral, and protective earth wires. These wires were transposed within a conduit, measured in pairs, with variations in the number and lengths of branches, assuming a deterministic modeling behavior of the electric power line. Throughout the experimentation process, essential parameters such as the magnitude of the S21 scattering parameters and VSWR identify frequency ranges suitable for efficient data transmission. The findings suggest remarkable prospects for enhancing PLC communication across MIMO channels. Depending on the combination of cable lines, over 70% of the bandwidth remains available. Additionally, the overall average impedance measured at 77.14 Ω is vital for impedance matching in PLC coupling circuit designs.
1 January 2025 in Journal of Microwaves, Optoelectronics and Electromagnetic Applications
This study investigates the effectiveness of employing Planar Transmission Lines (PTL) with stubs to determine the water content in transformer oils. The research aims to elucidate how transmission responses along the line can provide valuable patterns for oil characterization. Notable results were achieved, particularly in identifying representative frequencies for each range of S21 scattering parameters, enabling the derivation of well-fitted linear expressions for the data. These findings suggest promising potential for the practical application of this approach. This study contributes not only to the understanding of the proposed technique but also to the stimulation of subsequent research aiming to enhance and consolidate this analytical methodology.