Emil Kartalov

Dr. Emil Kartalov

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2003 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
IBIdo Braslavsky
Ido Braslavsky
BHBenedict Hebert
Benedict Hebert
EKEmil Kartalov
Emil Kartalov
SQStephen R. Quake
Stephen R. Quake
The completion of the human genome draft has taken several years and is only the beginning of a period in which large amounts of DNA and RNA sequence information will be required from many individuals and species. Conventional sequencing technology has limitations in cost, speed, and sensitivity, with the result that the demand for sequence information far outstrips current capacity. There have been several proposals to address these issues by developing the ability to sequence single DNA molecules, but none have been experimentally demonstrated. Here we report the use of DNA polymerase to obtain sequence information from single DNA molecules by using fluorescence microscopy. We monitored repeated incorporation of fluorescently labeled nucleotides into individual DNA strands with single base resolution, allowing the determination of sequence fingerprints up to 5 bp in length. These experiments show that one can study the activity of DNA polymerase at the single molecule level with single base resolution and a high degree of parallelization, thus providing the foundation for a practical single molecule sequencing technology.

1 January 2006 in BioTechniques
Verified
Journal Article
Open access
EKEmil Kartalov
Emil Kartalov
JZJiang F. Zhong
Jiang F. Zhong
ASAxel Scherer
Axel Scherer
SQStephen R. Quake
Stephen R. Quake
CTClive R. Taylor
Clive R. Taylor
WAW. French Anderson
W. French Anderson
Here we describe the development of a high-throughput multi-antigen microfluidic fluorescence immunoassay system. A 100-chamberpolydimethylsiloxane (PDMS) chip performs up to 5 tests for each of 10... Going with the Flow To make bedside and field diagnostics a reality, rather than just a Hollywood movie subplot, requires the miniaturization of assay components that normally would take up a signi...

15 August 2006 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
EKEmil Kartalov
Emil Kartalov
CWChristopher Walker
Christopher Walker
CTClive R. Taylor
Clive R. Taylor
WAW. French Anderson
W. French Anderson
ASAxel Scherer
Axel Scherer
We report on a fundamental technological advance for multilayer polydimethylsiloxane (PDMS) microfluidics. Vertical passages (vias), connecting channels located in different layers, are fabricated monolithically, in parallel, by simple and easy means. The resulting 3D connectivity greatly expands the potential complexity of microfluidic architecture. We apply the vias to printing nested bioarrays and building autoregulatory devices. A current source is demonstrated, while a diode and a rectifier are derived; all are building blocks for analog circuitry in Newtonian fluids. We also describe microfluidic septa and their applications. Vias lay the foundation for a new generation of microfluidic devices.

1 May 2004 in Nucleic Acids Research
Verified
Journal Article
Open access
PDF file
EKEmil Kartalov
Emil Kartalov
SQStephen R. Quake
Stephen R. Quake
We have developed the first fully integrated microfluidic system for DNA sequencing‐by‐synthesis. Using this chip and fluorescence detection, we have reliably sequenced up to 4 consecutive bps. The described sequencer can be integrated with other microfluidic components on the same chip to produce true lab‐on‐a‐chip technology. The surface chemistry that was designed to anchor the DNA to elastomeric microchannels is useful in a broad range of studies and applications.

15 March 2007 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
EKEmil Kartalov
Emil Kartalov
ASAxel Scherer
Axel Scherer
SQStephen R. Quake
Stephen R. Quake
CTClive R. Taylor
Clive R. Taylor
WAW. French Anderson
W. French Anderson
A systematic experimental study and theoretical modeling of the device physics of polydimethylsiloxane “pushdown” microfluidic valves are presented. The phase space is charted by 1587 dimension combinations and encompasses 45–295μm lateral dimensions, 16–39μm membrane thickness, and 1–28psi closing pressure. Three linear models are developed and tested against the empirical data, and then combined into a fourth-power-polynomial superposition. The experimentally validated final model offers a useful quantitative prediction for a valve’s properties as a function of its dimensions. Typical valves (80–150μm width) are shown to behave like thin springs.

1 December 2008 in Electrophoresis
Verified
Journal Article
Open access
PDF file
EKEmil Kartalov
Emil Kartalov
DLDavid H. Lin
David H. Lin
DLDavid T. Lee
David T. Lee
WAWilliam F. Anderson
William F. Anderson
CTClive R. Taylor
Clive R. Taylor
ASAxel Scherer
Axel Scherer
Herein we report on reliable reproducible quantification of protein analytes in human serum by fluorescence sandwich immunoassays in disposable PDMS microfluidic chips. The system requires 1000 times less sample than typical clinical blood tests and is specifically shown to measure ferritin down to 250 pM in human serum. The in‐built calibration method of spiking the serum with known concentrations of commercially available antigen avoids common sources of error and improves the reliability of the test results. The reported microfluidic system is an important new tool for fundamental scientific research, offering sensitive immunoassay measurements in small but complex biosamples. The system is also a further step towards comprehensive affordable “point‐of‐care” biomedical diagnostics.