Heng Zhang

Dr. Heng Zhang


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2023 in Journal of Zhejiang University-SCIENCE B
Verified
Journal Article
Closed access
PDF file
HCHui Cai
Hui Cai
HZHuimei Zhang
Huimei Zhang
WHWeiting He
Weiting He
HZHeng Zhang
Heng Zhang
Postmenopausal osteoporosis is a kind of degenerative disease, also described as “invisible killer.” Estrogen is generally considered as the ke

13 December 2021 in Orthopaedic Surgery
Verified
Journal Article
Open access
PDF file
HZHeng Zhang
Heng Zhang
JGJian‐Zhong Guan
Jian‐Zhong Guan
ZZZheng Zhang
Zheng Zhang
XCXiao‐Tian Chen
Xiao‐Tian Chen
XMXiao‐Dong Ma
Xiao‐Dong Ma
JZJian‐Sheng Zhou
Jian‐Sheng Zhou
Objective: To develop a new method to restore hip rotation center exactly and rapidly in total hip arthroplasty (THA) with the assistance of three dimensional (3D) printing technology and evaluate its clinical and radiological outcomes.Methods: From March 2014 to July 2018, a total of 17 patients (five hips of four men and 16 hips of 13 women) with end‐stage osteoarthritis secondary to developmental dysplasia of the hip who underwent THA were analyzed and followed up retrospectively. The average age is 58.00 ± 8.12 years (range from 45 to 71 years). Simulated operations were performed on 3D printed hip models for preoperative planning. The morphology of Harris fossa and acetabular notches were recognized and restored to locate the acetabular center. The size of bone defect was measured by the bone wax method. The agreement on the size of acetabular cup and bone defect between simulated operations and actual operations were analyzed. Harris Hip Score (HHS) was used to evaluate the recovery of hip joint function. The vertical distance and horizontal distance of the rotation center on the pelvis plain radiograph were measured, which were used to assess the efficacy of restoring hip rotation center and acetabular cup migration.Results: The mean sizes of bone defect in simulated operations and THA were 4.58 ± 2.47 cm2 and 4.55 ± 2.57 cm2 respectively. There was no significant difference statistically between the sizes of bone defect in simulated operations and the actual sizes of bone defect in THA (t = 0.03, P = 0.97). The sizes of the acetabular cup of simulated operations on 3D print models showed a high rate of coincidence with the actual sizes in the operations (ICC = 0.93). All 17 patients were available for clinical and radiological follow‐up. The average follow‐up time was 18.35 ± 6.86 months (range, 12–36 months. The average HHS of the patients was improved from (38.33 ± 6.07) preoperatively to the last follow‐up (88.61 ± 3.44) postoperatively. The mean vertical and horizontal distances of hip rotation center on the pelvic radiographs were restored to 15.12 ± 1.25 mm and 32.49 ± 2.83 mm respectively. No case presented dislocation or radiological signs of loosening until last follow‐up.Conclusions: The application of 3D printing technology facilitates orthopedists to recognize the morphology of Harris fossa and acetabular notches, locate the acetabular center and restore the hip rotation center rapidly and accurately.

29 October 2019 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
HZHeng Zhang
Heng Zhang
JZJiansheng Zhou
Jiansheng Zhou
JGJianzhong Guan
Jianzhong Guan
HDHai Ding
Hai Ding
ZWZhiyan Wang
Zhiyan Wang
QDQirong Dong
Qirong Dong
Purpose: To restore rotation center exactly in total hip arthroplasty (THA) is technically challenging for patients with end-stage osteoarthritis due to developmental dysplasia of the hip (DDH). The technical difficulty is attributable to the complex acetabular changes. In this study, we investigated the pathomorphology of acetabulum and Harris fossa of Crowe types I to IV and discussed the method of restoring rotation center of the hip. Methods: This study retrospectively reviewed 56 patients (59 hips) who underwent cementless THA due to end-stage osteoarthritis of DDH. The pathomorphology of acetabulum and Harris fossa was observed during operations. Using the preoperative and postoperative pelvic radiographs, the vertical and the horizontal distances of hip rotation center were measured in order to evaluate the effects of restoring rotation center of the hip. Results: Adult DDH acetabulum could be classified into four basic pathological types which include the shallow cup shape, the dish shape, the shell shape, and the triangular shape. Adult DDH Harris fossa could be classified into four pathological types, including the crack shape, the closed shape, the triangle shape, and the shallow shape, in accordance with the osteophyte coverage. The vertical and horizontal distances of hip rotation center on the pelvic radiographs before and after operations were as follows: the preoperative vertical distance of hip rotation center was (39.96 ± 5.65) mm, and the postoperative one was (13.83 ± 2.66) mm; the preoperative horizontal distance of hip rotation center was (42.15 ± 6.42) mm, and the postoperative one was (28.12 ± 4.56) mm. Conclusions: The acetabulum and Harris fossa can display different pathological types on account of different degrees of dislocation and osteophyte hyperplasia in the end-stage osteoarthritis of adult DDH. The hip rotation center can be accurately restored by locating the acetabular center with Harris fossa and acetabular notch as the marks.

2 October 2020 in Medicine
Verified
Journal Article
Open access
HZHeng Zhang
Heng Zhang
YLYang Liu
Yang Liu
QDQirong Dong
Qirong Dong
JGJianzhong Guan
Jianzhong Guan
JZJiansheng Zhou
Jiansheng Zhou
Exact restoration of the rotation center in total hip arthroplasty (THA) is technically challenging in patients with end-stage osteoarthritis due to developmental dysplasia of the hip (DDH), especially in the Crowe type II and III procedures. The technical difficulty is attributable to the complex acetabular changes. In this study, a novel 3-dimensional (3D) printed integral customized acetabular prosthesis for anatomical rotation restoration in THA for DDH Crowe type III was developed using patient-specific Computer-aided design and additive manufacturing (AM) methods. A 69-year-old female patient had developed left hip joint pain and restricted movement for 40 years; the symptoms had increased in the past 5 months. Pain, limited motion of the left hip joint, and lower limb length discrepancy were noted during physical examination. The patient was diagnosed with left hip end-stage osteoarthritis secondary to DDH (Crowe type III). A 3D printed acetabulum model was manufactured and a simulated operation was performed to improve the accuracy of reconstruction of the rotation center and bone defect. A 3D printed titanium alloy integral customized acetabular prosthesis was designed according to the result of simulated operation. The integral customized prothesis was implanted subsequently via the posterolateral approach. Radiography of the pelvis and Harris score assessment were performed during the perioperative period as well as at the 6- and 12-month follow-up. The 3D printed integral customized acetabular prosthesis matched precisely with the reamed acetabulum. The rotation center was restored and the bone defect was exactly reconstructed. There were no signs of prosthetic loosening at the 12-month follow-up. The Harris score gradually improved during the follow-up period. Satisfactory results of hip rotation restoration and bone defect reconstruction could be achieved by using 3D printed integral customized acetabular prosthesis, which provides a promising way to reconstruct the acetabulum in patients with DDH anatomically and rapidly for THA.

16 April 2020 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
HZHeng Zhang
Heng Zhang
JZJiansheng Zhou
Jiansheng Zhou
YLYang Liu
Yang Liu
JGJianzhong Guan
Jianzhong Guan
HDHai Ding
Hai Ding
QDQirong Dong
Qirong Dong
Background: To restore rotation center exactly in revision hip arthroplasty is technically challenging, especially in Paprosky type III. The technical difficulty is attributable to the complicated acetabular bone defect. In this study, we discussed the method of restoring rotation center in revision hip arthroplasty and reported the clinical and radiological outcome of mid-term and long-term follow-up. Methods: This study retrospectively reviewed 45 patients (48 hips) who underwent revision hip arthroplasty, in which 35 cases (35 hips) were available for complete follow-up data. During the operation, the acetabular bone defect was reconstructed by impaction morselized bone graft, and the hip rotation center was restored by using remnant Harris fossa and acetabular notches as the marks. The clinical outcome was assessed using the Harris hip score. Pelvis plain x-ray was used to assess implant migration, stability of implants, and incorporation of the bone graft to host bone. Result: The average follow-up duration was 97.60 months (range 72–168 months). The average Harris hip score improved from 29.54 ± 10.87 preoperatively to 83.77 ± 5.78 at the last follow-up. The vertical distance of hip rotation center measured on pelvis x-ray was restored to normal, with the mean distance (15.24 ± 1.31) mm (range 12.4~17.3 mm). The mean loss of vertical distance of hip rotation center was (2.21 ± 0.72) mm (range 1.1 ~ 5.3 mm) at the last follow-up. Conclusion: Satisfactory clinical and radiological outcome can be obtained through restoring hip rotation center by using remnant Harris fossa and acetabular notches as the anatomical marks in revision hip arthroplasty.

15 April 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HZHeng Zhang
Heng Zhang
JZJiansheng Zhou
Jiansheng Zhou
XLXiao Ling
Xiao Ling
HCHaonan Chen
Haonan Chen
MDMingqiu Du
Mingqiu Du
JZJianning Zhao
Jianning Zhao
The aim of this study was to explore a novel method to determine the orientation of acetabular prosthesis in total hip arthroplasty (THA) by refering to the anatomical landmarker of acetabular notches. Forty-one normal developmental hips were included in the present study. The acetabulums were reamed according to standard surgical procedures of THA on life-size 3D printing pelvis models. The inferior edge of acetabular cup were placed (1–5) mm proximal and distal to the proximal line of the anterior and posterior acetabular notches (PLAPAN) respectively to determine cup inclination. The inferior edge of acetabular cup were placed (1–5) mm pronating and supinating around the proximal point of acetabular posterior notch (PPAPN) respectively to determine cup anteversion. The pelvis plain radiographs were took and the inclination and anteversion of the acetabular cup at 22 positions were calculated. In the normal developmental hip, the mean inclination of acetabular prothesis were (35.10 ± 3.22)° and (45.90 ± 2.68)° when the inferior edge of the acetabular cup was 3 mm proximal and 1 mm distal to the PLAPAN. The optimal cup inclination could be obtained when the inferior edge of the acetabular cup was 1 mm proximal to the PLAPAN (the mean inclination was (40.71 ± 2.80)°). The mean anteversion of acetabular prothesis were (10.67 ± 4.55)° and (20.86 ± 4.44)° when the inferior edge of the acetabular cup was 1 mm pronating and 1 mm supinating around the PPAPN. The optimal cup anteversion could be obtained when the inferior edge of the acetabular cup was parallel to the PLAPAN (the mean anteversion was (18.00 ± 1.64)°). The inclination and anteversion of acetabular prosthesis could be determined by refering the anatomical landmarks of acetabular notches, which could help orthopedists to install the acetabular prosthesis quickly and safely in THA.