Bruno Boulanger

Prof. Bruno Boulanger

PharmaLex, Louvain-la-Neuve, Wallonia, Belgium

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2022 in Molecules
Verified
Journal Article
Open access
PDF file
TLThomas Van Laethem
Thomas Van Laethem
PKPriyanka Kumari
Priyanka Kumari
BBBruno Boulanger
Bruno Boulanger
PHPhilippe Hubert
Philippe Hubert
MFMarianne Fillet
Marianne Fillet
CHCédric Hubert
Cédric Hubert
In the pharmaceutical field, and more precisely in quality control laboratories, robust liquid chromatographic methods are needed to separate and analyze mixtures of compounds. The development of such chromatographic methods for new mixtures can result in a long and tedious process even while using the design of experiments methodology. However, developments could be accelerated with the help of in silico screening. In this work, the usefulness of a strategy combining response surface methodology (RSM) followed by multicriteria decision analysis (MCDA) applied to predictions from a quantitative structure–retention relationship (QSRR) model is demonstrated. The developed strategy shows that selecting equations for the retention time prediction models based on the pKa of the compound allows flexibility in the models. The MCDA developed is shown to help to make decisions on different criteria while being robust to the user’s decision on the weights for each criterion. This strategy is proposed for the screening phase of the method lifecycle. The strategy offers the possibility to the user to select chromatographic conditions based on multiple criteria without being too sensitive to the importance given to them. The conditions with the highest desirability are defined as the starting point for further optimization steps.

25 December 2024
Verified
Book Chapter
Closed access
PDF file
MMMarco Munda
Marco Munda
JCJianmin Chen
Jianmin Chen
ADAnaïs Debard
Anaïs Debard
SGSandrine Guilleminot
Sandrine Guilleminot
BCBradley P. Carlin
Bradley P. Carlin
BBBruno Boulanger
Bruno Boulanger

19 January 2023 in Biologics
Verified
Journal Article
Open access
PDF file
ACArjen Companjen
Arjen Companjen
SMSusan Moore
Susan Moore
BBBruno Boulanger
Bruno Boulanger
SKStefan Kostense
Stefan Kostense
WMWilfred Marissen
Wilfred Marissen
Assessment of rabies virus (RABV) neutralizing antibodies in subjects vaccinated or injected with anti-RABV immunoglobulins is central in determination of rabies protection. The rapid fluorescent focus inhibition test (RFFIT) is used for assessment of anti-RABV activity in serum. The current anti-RABV polyclonal preparations on the market pose difficulties in production and vary in quality. RABV neutralizing monoclonal antibodies (MAbs) are being evaluated as replacements. Different anti-RABV MAbs may neutralize different RABV isolates, thus two or more MAbs directed against different epitopes on the RABV glycoprotein are needed. It is therefore important to ensure neutralizing activity against all RABV isolates in sera of subjects injected with an anti-RABV MAb product consisting of two or more MAbs. The RFFIT, utilizing CVS-11 as challenge virus, cannot discriminate between the activities of different anti-RABV MAbs. We developed and validated two RFFIT methods enabling specific assessment of two different anti-RABV MAbs (CR57 and CR4098) in using two mutant CVS-11 strains resistant to either CR57 or CR4098 neutralization. The validation results demonstrate that both RFFIT assays using MAb resistant RABV are precise, accurate, linear, specific, and stable within the linear range of 0.025 IU/mL to 1.0 IU/mL. This method design can, therefore, be used to determine MAb specific anti-RABV activity in human serum samples.