Localization and forest fire suppression is an urgent problem for the whole world. Given the heterogeneity of forests on the planet, approaches to modeling the spread of fires and their extinguishing are different. In this article a method for determining the required number of forces and means for the localization of ground forest fires is offered, taking into account the location of firefighting equipment in forests. To forecast the spread of fire, equidistant places from the fire departments in forests were chosen using Voronoi diagrams. The results of the calculation make it possible to conclude whether there are enough available forces and means to localize the predicted fire and to suggest additional firefighting equipment locations. The use of Voronoi diagrams for the State Enterprise "Zhovkva Forestry" in the Lviv region showed 12 dangerous areas, which are located the furthest from the fire departments. The method for determining the optimal location of firefighting equipment was applied to the Butynskyi forestry in Zhovkva forestry enterprise. Reducing the time of free spread of ground forest fires by 25% using rational placement of firefighting equipment and machinery, allows to reduce the number of employees for its localization by 53.8%.
1 August 2025 in Ecological Engineering & Environmental Technology
The study investigates the patterns and ecological consequences of vegetation succession in areas affected by ground fires within the Roztochya region of Ukraine. The objective was to identify key stages and drivers of post-pyrogenic vegetation recovery and assess the role of dominant species in...
28 February 2025 in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
Purpose. Establishing the feasibility of using the FDS computer model to determine the specific consumption rate of finely sprayed water for extinguishing wood as an alternative to physical modeling. Methodology. The study utilized the functionality of the Fire Dynamics Simulator (FDS) computer model; a methodology for determining the consumption and volume of extinguishing agents for extinguishing model fires of type 1A for various wood species within a specially designed testing ground for experimental fire tests; the results of the research were processed using Microsoft Excel. Findings. According to the results of computer modeling, it was established that for the combustion of selected wood species over a duration of 0–180 seconds, the highest temperature in the fire center occurs for fir at 173 seconds, reaching 1,180 °C. The peak temperature in the combustion environment for common pine is observed at 170 seconds, measuring 1,165 °C. The temperatures for silver birch and common oak were lower, at 1,000 °C (178 seconds) and 855 °C (173 seconds), respectively. After applying finely sprayed water to the fire center of the model fires made of pine and fir, the temperature decreased below the ignition point after 57 seconds, with a water consumption rate of 2 l/s. For the extinguishing of model fires made of oak and birch, the extinguishing effect was observed at 135 and 105 seconds, respectively. Based on the conducted research, the specific consumption rates of finely sprayed water for extinguishing common oak and common pine were determined to be 168 and 120 l/m³, respectively. Originality. For the first time, the Fire Dynamics Simulator (FDS) computer model was used to simulate the extinguishing process for four of the most common types of forests – common pine, Douglas fir, silver birch, and common oak. It was established that when extinguishing fires in coniferous wood species with a finely sprayed water consumption rate of 2 l/s, the extinguishing effect is achieved at 57 seconds. Practical value. The conducted computer modeling and experimental field studies allowed for the determination of the calculated amount of finely sprayed water needed for extinguishing fires in various wood species. The specific consumption rates of extinguishing agents for fighting fires in coniferous and deciduous wood species can be used for calculating the forces and resources required for firefighting in forested areas.
30 April 2020 in Eastern-European Journal of Enterprise Technologies
A mathematical model and methodology has been developed to determine the optimal amount of means of a fire-prevention system for protecting warehouses in enclosed spaces, on the basis of which it is possible to determine measures to improve this system, taking into account the value of the probability of its failure acceptable for the warehouse. The essence of the developed methodology is to determine the required number of fire protection equipment in accordance with the standards, to determine the probability of failure of fire protection and to determine the optimal number of fire protection equipment to ensure the value of the probability of failure within acceptable limits. The optimization criteria selected direct losses from the fire and the costs of fire and rescue units to extinguish it. The function of the goal of this model is to reduce the probability of failure of the fire system of the object to a value less than or equal to the permissible. The input data when using the mathematical model is the estimated number of fire protection equipment in accordance with the norms and standards.The developed methodology allows predicting the probability of failure of the fire system to implement the fire safety of the objects of protection and its consequences for people and material values, which is very important to ensure the possibility of quick response in case of fire. Also, the result of applying the technique is the optimal amount of firefighting equipment at the facility, providing an acceptable value for the probability of failures. This technique is applied on the example of an existing logistic warehouse on which fire protection systems are mounted. Simulation results show that at the facility it is necessary to increase the number of fire detectors up to 70 pieces, smoke control devices – up to 3 pieces, vertical curtains – up to 4, equip aeration lamps in the amount of 4 pieces, and increase the number of evacuation exits - up to 10
30 April 2022 in Eastern-European Journal of Enterprise Technologies
An integral condition for avoiding damage due to fires in warehouses, or at least minimizing them, is the early detection of fires using fire protection systems, as well as its timely localization. Depending on which fire detectors are selected to protect the relevant premises and where they are installed, the time of operation of all elements of automatic control systems in case of a fire will depend. The review of literary data revealed that at present there is no comprehensive approach to choosing the optimal placement in warehouses. In addition, the optimal placement of fire detectors within the room, taking into consideration the type of fire load, has not been sufficiently studied. Therefore, the purpose of the current study is to establish the dependence of the time of operation of different types of fire detectors on the type of combustible material, namely its mass burnout rate, distance, and height of placement of detectors from a potential fire site. This paper reports a procedure for conducting an experimental study to identify the appropriate dependence for warehouses. The results of the experiments showed that the most effective in warehouses are targeted fire smoke detectors and aspiration systems. Based on the results of a complete factor experiment, nonlinear empirical dependences to determine the time of operation of smoke fire detectors on the above factors were built. The resulting empirical dependences make it possible to choose fire detectors and optimally place them within a room. The average error in these dependences when compared with the experimental data is 6.9 %. The use of the derived dependences makes it possible to reduce the time of operation of fire detectors by 14 s in comparison with their placement in accordance with building codes