Bakhram Gaynullin

Mr. Bakhram Gaynullin


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2019 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
EAEmmanuel Arzoumanian
Emmanuel Arzoumanian
FVFelix Vogel
Felix Vogel
ABAna Bastos
Ana Bastos
BGBakhram Gaynullin
Bakhram Gaynullin
OLOlivier Laurent
Olivier Laurent
PCPhil Ciais
Phil Ciais
CO2 emission estimates from urban areas can be obtained with a network of in situ instruments measuring atmospheric CO2 combined with high-resolution (inverse) transport modelling. Because the distribution of CO2 emissions is highly heterogeneous in space and variable in time in urban areas, gradients of atmospheric CO2 (here, dry air mole fractions) need to be measured by numerous instruments placed at multiple locations around and possibly within these urban areas. This calls for the development of lower-cost medium-precision sensors to allow a deployment at required densities. Medium precision is here set to be a random error (uncertainty) on hourly measurements of ±1 ppm or less, a precision requirement based on previous studies of network design in urban areas. Here we present tests of newly developed non-dispersive infrared (NDIR) sensors manufactured by Senseair AB performed in the laboratory and at actual field stations, the latter for CO2 dry air mole fractions in the Paris area. The lower-cost medium-precision sensors are shown to be sensitive to atmospheric pressure and temperature conditions. The sensors respond linearly to CO2 when measuring calibration tanks, but the regression slope between measured and assigned CO2 differs between individual sensors and changes with time. In addition to pressure and temperature variations, humidity impacts the measurement of CO2, with all of these factors resulting in systematic errors. In the field, an empirical calibration strategy is proposed based on parallel measurements with the lower-cost medium-precision sensors and a high-precision instrument cavity ring-down instrument for 6 months. The empirical calibration method consists of using a multivariable regression approach, based on predictors of air temperature, pressure and humidity. This error model shows good performances to explain the observed drifts of the lower-cost medium-precision sensors on timescales of up to 1–2 months when trained against 1–2 weeks of high-precision instrument time series. Residual errors are contained within the ±1 ppm target, showing the feasibility of using networks of HPP3 instruments for urban CO2 networks. Provided that they could be regularly calibrated against one anchor reference high-precision instrument these sensors could thus collect the CO2 (dry air) mole fraction data required as for top-down CO2 flux estimates.

6 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
BGBakhram Gaynullin
Bakhram Gaynullin
CHChristine Hummelgård
Christine Hummelgård
CMClaes Mattsson
Claes Mattsson
GTGöran Thungström
Göran Thungström
HRHenrik Rödjegård
Henrik Rödjegård
Measurements of atmospheric gas concentrations using of NDIR gas sensors requires compensation of ambient pressure variations to achieve reliable result. The extensively used general correction method is based on collecting data for varying pressures for a single reference concentration. This one-dimensional compensation approach is valid for measurements carried out in gas concentrations close to reference concentration but will introduce significant errors for concentrations further away from the calibration point. For applications, requiring high accuracy, collecting, and storing calibration data at several reference concentrations can reduce the error. However, this method will cause higher demands on memory capacity and computational power, which is problematic for cost sensitive applications. We present here an advanced, but practical, algorithm for compensation of environmental pressure variations for relatively low-cost/high resolution NDIR systems. The algorithm consists of a two-dimensional compensation procedure, which widens the valid pressure and concentrations range but with a minimal need to store calibration data, compared to the general one-dimensional compensation method based on a single reference concentration. The implementation of the presented two-dimensional algorithm was verified at two independent concentrations. The results show a reduction in the compensation error from 5.1% and 7.3%, for the one-dimensional method, to −0.02% and 0.83% for the two-dimensional algorithm. In addition, the presented two-dimensional algorithm only requires calibration in four reference gases and the storing of four sets of polynomial coefficients used for calculations.

30 October 2022
Verified
Conference Paper
Closed access
BGBakhram Gaynullin
Bakhram Gaynullin
CHChristine Hummelgard
Christine Hummelgard
HRHenrik Rodjegard
Henrik Rodjegard
CMClaes Mattsson
Claes Mattsson
GTGoran Thungstrom
Goran Thungstrom
A multispectral nondispersive infrared (NDIR) sensor was developed for simultaneous detection of methane and water vapor in air. The NDIR sensor is capable of measuring optic transmission in the CH4 absorption spectra at 3.375 $\mu\mathrm{m}$ and the H 2 O absorption spectra at 2.7 $\mu\mathrm{m}$ . Data from a third channel, 3.95 $\mu\mathrm{m}$ , is used as reference value for “zero-level” calibration. The actual CH4 concentration is retrieved by adjusting the data obtained in the $\text{CH}_{4}$ spectra with respect to the concentration sensed in the $\mathrm{H}_{2}\mathrm{O}$ spectra. A calibration procedure was developed and tested, which involves matching of the absorbed light energy in the CH4 and the $\mathrm{H}_{2}\mathrm{O}$ spectrum in humid reference environments. A compensation algorithm for elimination of humidity impact was developed and validated in environments with variable $\text{CH}_{4}$ and H 2 O concentrations. By implementing the multispectral approach, and the developed algorithm, an uncertainty of 15–25 ppm relative the reference concentrations was achieved. For a concentration range valid for environmental monitoring applications this should be compared to an uncertainty of 180–200 ppm for the non-corrected CH4 concentration.

20 October 2024
Verified
Conference Paper
Closed access
BGBakhram Gaynullin
Bakhram Gaynullin
HRHenrik Rödjegård
Henrik Rödjegård
CMClaes Mattsson
Claes Mattsson
CHChristine Hummelgård
Christine Hummelgård
GTGöran Thungström
Göran Thungström
A system for the measurement of methane concentration in water is presented. The system is a stand- alone device using a high-resolution NDIR (Non-Dispersive Infra-Red) gas sensor. The NDIR sensor is configured to measure methane, water vapor, and carbon dioxide in the air. It is mounted in a housing with a stabilized environment and includes cross-sensitivity compensation. An equilibrator is used to transfer the methane concentration from the water into a circulating gas flow that is analyzed by the NDIR gas sensor. The equilibrator consists of a vertical plastic tube filled with 2,000 glass marbles, where the water runs from top to bottom on the surface of the glass marbles, in contact with a circulating air flow, exchanging gas. The system is stand- alone, including power supply and logging features for 72 hours of operation. The system performance was evaluated in a field test, measuring the methane content of seawater at a fiber bank in Sundsvall, Sweden. This fiber bank consists of remaining waste from an old paper industry from before 1970 and is known to produce methane. The detection limit of the tested system is below 1.4 nmol/L in water, corresponding to 1 ppm methane concentration in the air. The settling time of the system in its current configuration, including the equilibrator and gas sensor housing, is 30 minutes.

4 October 2018 in EGUsphere
Verified
Preprint
Open access
PDF file
EAEmmanuel Arzoumanian
Emmanuel Arzoumanian
FVFelix Vogel
Felix Vogel
ABAna Bastos
Ana Bastos
BGBakhram Gaynullin
Bakhram Gaynullin
OLOlivier Laurent
Olivier Laurent
PCPhil Ciais
Phil Ciais
CO2 emission estimates from urban areas can be obtained with a network of in-situ instruments measuring atmospheric CO2 combined with high-resolution (inverse) transport modeling. The distribution of CO2 emissions being highly heterogeneous in space and variable in time in urban areas, gradients of atmospheric CO2 need to be measured by numerous instruments placed at multiple locations around and possibly within these urban areas, which calls for the development of lower-cost medium precision sensors to allow a deployment at required densities. Medium precision is here set to be a random error (uncertainty) on hourly measurements of ±1 ppm or less, a precision requirement based on previous studies of network design in urban areas. Here we present tests of a HPP commercial NDIR sensors manufactured by Senseair AB performed in the laboratory and at actual field stations, the latter for CO2 concentration in the Paris area. The lower-cost medium precision sensors are shown to be sensitive to atmospheric pressure and temperature conditions. The sensors respond linearly to CO2 when measuring calibration tanks, but the regression slope between measured and true CO2 differs between individual sensors and changes with time. In addition to pressure and temperature variations, humidity impacts the measurement of CO2, all causing systematic errors. In the field, an empirical calibration strategy is proposed based on parallel measurements with the lower-cost medium precision sensors and a high-precision instrument cavity ring-down instrument during 6 month. This empirical calibration method consists of using a multiple regression approach to create a model of the errors defined as the difference of CO2 measured by the lower-cost medium precision sensors relative to a calibrated high-precision instrument, based on predictors of air temperature, pressure and humidity. This error model shows good performances to explain the observed drifts of the lower-cost medium precision sensors on time scales of up to 1–2 months when trained against 1–2 weeks of high-precision instrument time series. Residual errors are contained within the ±1 ppm target, showing the feasibility to use networks of HPP instruments for urban CO2 networks, provided that they could be regularly calibrated against one anchor reference high-precision instrument.

14 March 2026
Verified
Other
Open access
HGHuy Duong Gia
Huy Duong Gia
FDFederico Dallo
Federico Dallo
THTorbjørn Heltne
Torbjørn Heltne
MGMoritz Gehlmann
Moritz Gehlmann
BWBenoit Wastine
Benoit Wastine
TCTuan-Vu Cao
Tuan-Vu Cao
Wetlands are among the most dynamic and climate-relevant biogeochemical reactors on Earth, acting simultaneously as strong sinks and sources of carbon dioxide (CO2) and methane (CH4). Their gas exchange with the atmosphere is controlled by interacting hydrological, biological, and physical drivers operating on timescales from minutes to seasons. Capturing this complexity requires high-frequency flux measurements across space and time, yet traditional chamber and analyzer systems remain expensive, power-intensive, and difficult to deploy in remote or waterlogged environments, limiting spatial coverage and long-term observations. Within the MISO project[1], we developed and tested a new generation of low-cost, autonomous greenhouse-gas sensing systems integrated with state-of-the-art automated wetland chambers and with new portable manual chambers designed specifically for hard-to-reach ecosystems. Our approach combines compact multi-gas NDIR sensors capable of measuring CO2, CH4, and H2O with robust calibration pipelines based on co-location with reference-grade analyzers and machine-learning-driven correction models. By explicitly modelling nonlinear effects of humidity, temperature, and pressure, these data-driven calibrations enable low-cost sensors to reproduce reference-quality gas concentration dynamics under the high-humidity and rapidly changing conditions typical of wetlands. Field deployments in boreal peatlands demonstrate that calibrated low-cost sensors integrated inside automated chambers closely track reference CO2 and, in some conditions, even CH4 concentrations during chamber closure cycles, enabling reliable flux estimation under both light and dark conditions. This performance is achieved with hardware that consumes far less power and is far easier to deploy and maintain than conventional high-end gas analyzers. In parallel, we developed a portable, lightweight manual chamber system prototype that combines the same low-cost sensing technology with a rugged, field-ready enclosure. This system would enable rapid, flexible flux measurements at sites that are inaccessible to heavy infrastructure, such as floating peat mats, remote fen systems, or seasonally flooded areas. Beyond hardware, MISO places strong emphasis on data usability and transparency. We created a user-friendly interactive annotation platform[2] that allows operators to visually inspect high-frequency chamber time series and label key events such as chamber closure, background periods, disturbances, or sensor transitions directly on the timeline. These annotations are stored in a structured format and propagated into downstream flux calculations, providing traceability and reproducibility that are often missing in automated chamber datasets. Together, these developments demonstrate how low-cost sensors, when combined with advanced calibration, automated chambers, and intuitive data tools, can ease wetland GHG monitoring. By lowering logistical and financial barriers, portable and autonomous systems make it feasible to expand flux measurements into previously under-sampled wetland regions, improving spatial representativeness and analyses of GHG production, consumption, and transport. This integrated approach supports the transition from sparse, site-specific flux measurements toward dense, process-oriented wetland GHG observing networks capable of capturing the true complexity of ecosystem–atmosphere exchange. [1] https://cordis.europa.eu/project/id/101086541 [2] https://github.com/theRosyProject/MISOChambers-GUI-APP