Gabriela Roca

Dr. Gabriela Roca

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2017 in International journal of legal medicine
Verified
Journal Article
Open access
PDF file
HHHannah Holtkötter
Hannah Holtkötter
CFClaudemir Rodrigues Dias Filho
Claudemir Rodrigues Dias Filho
KSKristina Schwender
Kristina Schwender
CSChristian Stadler
Christian Stadler
MVMarielle Vennemann
Marielle Vennemann
GRGabriela Roca
Gabriela Roca
Sexual assault is a serious offense and identification of body fluids originating from sexual activity has been a crucial aspect of forensic investigations for a long time. While reliable tests for the detection of semen and saliva have been successfully implemented into forensic laboratories, the detection of other body fluids, such as vaginal or menstrual fluid, is more challenging. Especially, the discrimination between peripheral and menstrual blood can be highly relevant for police investigations because it provides potential evidence regarding the issue of consent. We report the forensic validation of an immunochromatographic test that allows for such discrimination in forensic stains, the SERATEC PMB test, and its performance on real casework samples. The PMB test is a duplex test combining human hemoglobin and D-dimer detection and was developed for the identification of blood and menstrual fluid, both at the crime scene and in the laboratory. The results of this study showed that the duplex D-dimer/hemoglobin assay reliably detects the presence of human hemoglobin and identifies samples containing menstrual fluid by detecting the presence of D-dimers. The method distinguished between menstrual and peripheral blood in a swab from a historical artifact and in real casework samples of alleged sexual assaults. Results show that the development of the new duplex test is a substantial progress towards analyzing and interpreting evidence from sexual assault cases.

Verified
Journal Article
Open access
PDF file
Francisco Medina PazFrancisco Medina Paz
Francisco Medina Paz
BKBrandon Kuba
Brandon Kuba
EKEmily Kryvorutsky
Emily Kryvorutsky
GRGabriela Roca
Gabriela Roca
Sara C. ZapicoSara C. Zapico
Sara C. Zapico
Body fluid identification plays a crucial role in criminal investigations. Because of their presence in many cases, blood and semen are the most relevant body fluids in forensic sciences. Based on antigen–antibody reactions binding unique proteins for each body fluid, serological assays represent one of the most rapid and highly specific tests for blood and semen. Currently, few studies have assessed the factors affecting body fluid identification by applying these assays. This work aimed to study the effect of different fabrics from clothes and time since deposition on identification through immunochromatographic tests for blood and semen, DNA isolation, and STR profiling from these samples. Body fluids were deposited on black- and white-dyed denim and cotton fabrics, and on leather. Afterward, blood and semen were sampled at 1 day, 30 days, and 90 days after deposition and identified by using the SERATEC® HemDirect Hemoglobin Test and the PSA Semiquant and SERATEC® BLOOD CS and SEMEN CS tests, respectively. Laboratory and crime scene tests presented similar performances for the detection of blood and semen stains on every tested fabric. No differences were found on band intensities between timepoints for all fabrics. It was possible to recover and identify blood and semen samples up to three months after deposition and to obtain full STR profiles from all the tested fabrics. Both body fluid STR profiles showed differences in their quality between 1 and 90 days after deposition for all fabrics except for black cotton for semen samples. Future research will expand the results, assessing body fluid identification on other substrates and under different environmental conditions.

15 August 2023 in Forensic Science, Medicine and Pathology
Verified
Journal Article
Closed access
PDF file
Sara C. ZapicoSara C. Zapico
Sara C. Zapico
GRGabriela Roca
Gabriela Roca

Verified
Journal Article
Open access
PDF file
Sara C. ZapicoSara C. Zapico
Sara C. Zapico
ADAlex Dytso
Alex Dytso
LETICIA RUBIOLETICIA RUBIO
LETICIA RUBIO
GRGabriela Roca
Gabriela Roca
Body fluid identification at crime scenes can be crucial in retrieving the appropriate evidence that leads to the perpetrator and, in some cases, the victim. For this purpose, immunochromatographic tests are simple, fast and suitable for crime scenes. The potential sample is retrieved with a swab, normally a cotton swab, moistened in a specific buffer. Nonetheless, there are other swab types available, which have been proven to be efficient for DNA isolation and analysis. The aim of this study is to evaluate the efficiency of different swab types for body fluid identification as well as DNA isolation and characterization. Fifty microliters of human saliva were deposited in three different types of fabric (denim, cotton, and polyester). After 24 h at room temperature, samples were recovered by applying three different swab types, and the tests were performed. Subsequently, total DNA was recovered from the sample buffer. Cotton swabs performed worse in denim and cotton fabrics in both immunochromatography tests and DNA yield. No differences were observed for polyester. In contrast, and except for two replicates, it was possible to obtain a full DNA profile per fabric and swab type, and to identify the mtDNA haplogroup. In this paper, the impact of swab types on body fluid identification through the application of immunochromatographic tests is analyzed for the first time. This work corroborates previous research related to the influence of swab types in nuclear DNA isolation and characterization.

9 May 2025 in Journal of Forensic and Legal Medicine
Verified
Journal Article
Closed access
Francisco Medina PazFrancisco Medina Paz
Francisco Medina Paz
MCMaría Josefina Castagnola
María Josefina Castagnola
VYVasilisa Yukhno
Vasilisa Yukhno
DUDayanara Ulloa
Dayanara Ulloa
CSChristian Stadler
Christian Stadler
Sara C. ZapicoSara C. Zapico
Sara C. Zapico

15 January 2024 in Methods and Protocols
Verified
Journal Article
Open access
PDF file
Sara C. ZapicoSara C. Zapico
Sara C. Zapico
GRGabriela Roca
Gabriela Roca
Lateral flow immunochromatographic (LFI) tests are widely used in both biomedical and forensic sciences for different applications. In forensic sciences, their main use is to detect body fluids at crime scenes. However, there are situations in which the amount of potential biological evidence is so low that DNA extraction is favored with respect to the identification of body fluids. Here, an efficient and quick protocol is presented to integrate the detection of body fluids through LFI with DNA extraction from a sample swab and buffer, providing a complete characterization of the biological evidence. This protocol is a modification of a general DNA extraction silica-based kit, whose main application is for blood and tissues. Thus, it could be carried out in different settings (forensic labs, hospitals, other testing labs) without the necessity of buying a specific kit for swabs. The validation of this protocol is supported by the results presented here and previous publications from our group, obtaining DNA in good quantity and with good quality. This proves the potential application of the protocol in both forensic scenarios, to fully characterize biological evidence, and biomedical settings, to molecularly confirm the results of LFI tests.