Virgilio Morales-Canton

Dr. Virgilio Morales-Canton


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2018 in International Journal of Retina and Vitreous
Verified
Journal Article
Open access
PDF file
RVRaul Velez-Montoya
Raul Velez-Montoya
JRJuan Ramírez-Estudillo
Juan Ramírez-Estudillo
CLCarl Sjoholm-Gomez de Liano
Carl Sjoholm-Gomez de Liano
FBFrancisco Bejar-Cornejo
Francisco Bejar-Cornejo
JSJorge Sanchez-Ramos
Jorge Sanchez-Ramos
SMSergio E. Hernandez-Da Mota
Sergio E. Hernandez-Da Mota
To assess closure rate after a single surgery of large macular holes and their visual recovery in the short term with three different surgical techniques. Prospective multicenter randomized controlled trial. We included treatment-naïve patients with diagnosis of large macular hole (minimum diameter of > 400 µm). All patients underwent a comprehensive ophthalmological examination. Before surgery, the patients were randomized into three groups: group A: conventional internal limiting membrane peeling, group B: inverted-flap technique and group C: free-flap technique. All study measurements were repeated within the period of 1 and 3 months after surgery. Continuous variables were assessed with a Kruskal–Wallis test, change in visual acuity was assessed with analysis of variance for repeated measurements with a Bonferroni correction for statistical significance. Thirty-eight patients were enrolled (group A: 12, group B: 12, group C: 14). The closure rate was in group A and B: 91.6%; 95% CI 61.52–99.79%. In group C: 85.71%; 95% CI 57.19–98.22%. There were no differences in the macular hole closure rate between groups (p = 0.85). All groups improved ≈ 0.2 logMAR, but only group B reached statistical significance (p < 0.007). Despite all techniques displayed a trend toward visual improvement, the inverted-flap technique seems to induce a faster and more significant recovery in the short term.

11 July 2017 in Eye and Vision
Verified
Journal Article
Open access
PDF file
CLCarl Sjoholm-Gomez de Liano
Carl Sjoholm-Gomez de Liano
VSVidal F. Soberon-Ventura
Vidal F. Soberon-Ventura
GSGuillermo Salcedo-Villanueva
Guillermo Salcedo-Villanueva
ASAbril Santos-Palacios
Abril Santos-Palacios
JGJose Luis Guerrero-Naranjo
Jose Luis Guerrero-Naranjo
RVRaul Velez-Montoya
Raul Velez-Montoya
To assess the sensitivity, specificity, positive predictive value and negative predictive value of anterior chamber tap for the diagnosis of bacterial endophthalmitis on a population with high prevalence. Retrospective, single centre, case series study. We reviewed all medical records with clinical diagnosis of bacterial endophthalmitis in our hospital from January 1st, 2000 to December 31st 2014. From each record, we documented general demographic data, best corrected visual acuity and vitreous and aqueous tap microbiological results. All cases were further divided according to the endophthalmitis aetiology to perform individual calculations of sensitivity, specificity, positive predictive value, negative predictive value, accuracy and prevalence. We used the results of the vitreous tap as the gold standard for diagnosis of bacterial endophthalmitis. We excluded those records in which the aqueous and vitreous samples were not taken simultaneously or had an incomplete microbiological report. Significance were assessed with chi squared statistics, with an alpha value of 0.05 for statistical significance. A total of 190 cases fulfilled the inclusion/exclusion criteria. Positive culture rate from vitreous samples was 64.74%. Positive culture rate from aqueous sample was 32.11%. Bacteria isolated from aqueous samples matched those isolated from vitreous samples 78.68% of the time. The overall sensitivity was 38.21%, specificity: 75.51%, positive predictive value: 79.66%, negative predictive value: 32.74% (p = 0.08). Subgroup analysis showed that anterior chamber taps in cases of post-surgical endophthalmitis had a moderate to low sensitivity (37.73%), high specificity (93%) and high positive predictive value (95%) (p < 0.04). The sensitivity and specificity of anterior chamber tap are low and should not be used for critical therapeutic decisions in patients with suspected bacterial endophthalmitis. In cases of post-surgical endophthalmitis, the result of an anterior chamber tap could be used for therapeutic guidance, but only in conjunction with clinical presentation and in the absence of a better method for diagnosis.

16 January 2017 in International Journal of Retina and Vitreous
Verified
Journal Article
Open access
PDF file
MMMaria Ana Martinez-Castellanos
Maria Ana Martinez-Castellanos
RVRaul Velez-Montoya
Raul Velez-Montoya
KPKenneth Price
Kenneth Price
AHAndree Henaine-Berra
Andree Henaine-Berra
GGGerardo Garcia-Aguirre
Gerardo Garcia-Aguirre
LCLinda Alejandra Cernichiaro-Espinosa
Linda Alejandra Cernichiaro-Espinosa
To describe a wide array of peripheral vascular changes using fluorescein angiography in preterm neonates, without high risk characteristics for developing retinopathy of prematurity, that were exposed to high oxygen concentration. Retrospective, two center, case series. Newborns at two different hospitals with ≥1500 g or gestational age of ≥32 weeks, fluorescein angiography performed, and with high oxygen exposure without adequate control were included. 294 infants diagnosed with ROP were analyzed. Only 28 eyes from 14 patients with peripheral vascular abnormalities in older and heavier babies were included. Two distinct type of peripheral vascular changes were observed: group 1 or non-proliferative: areas of capillary non-perfusion along with widespread arteriovenous shunting between adjacent primary vessels, tortuosity of primary vessels, abnormal budding of tertiary vessels and capillaries, abnormal capillary tufts and absence of foveal avascular zone; group 2 or proliferative: all of the characteristics of group 1 plus leakage of dye from the boundary between perfused and non-perfused retina and/or optic disc. Peripheral vascular abnormalities different from retinopathy of prematurity are observed in older than 32 weeks of gestational age, and heavier than 1500 g babies. This makes the authors classify these patients as having a disease caused solely by oxygen dysregulation at the neonatal intensive care unit similarly to the oxygen induced retinopathy in experimental studies.

23 January 2017 in International Journal of Retina and Vitreous
Verified
Journal Article
Open access
GDGian Franco Díez-Cattini
Gian Franco Díez-Cattini
DADavid Arturo Ancona-Lezama
David Arturo Ancona-Lezama
CVCarlos Valdés-Lara
Carlos Valdés-Lara
VMVirgilio Morales-Canton
Virgilio Morales-Canton
Classic retinitis pigmentosa (RP) and other syndromic variants have previously been associated to Fuchs' heterochromic iridocyclitis (FHI). Common immunogenic and inflammatory pathways have been proposed to explain the higher incidence of this uveitic phenomenon in patients with retinal dystrophies without definitive answers. Infrequent variants of RP such as inverse RP have not been previously reported in association with FHI. We believe that finding the way these entities connect can shed some light into their complex pathogenesis and help find ways to foresee and prevent the appearance of complications such as cataract and macular edema. We present a 15 year old mexican male with history of nyctalopia and rapid, progressive visual loss since infancy who had profound hyper and hypopigmented retinal pigment epithelium changes in the posterior pole together with pigment clumping in the macula of both eyes and an electroretinogram pattern consistent of rod-cone dystrophy. He was diagnosed with inverse RP. Three years after his first visit he was found to have a mild asymptomatic non granulomatous anterior uveitis in the right eye with fine stellate keratic precipitates and subtle iris stromal atrophy not associated with iris synechiae and without evidence of posterior uveitis or findings consistent with infectious etiology. Findings were consistent with FHI. As the patient was normotensive, the lens was transparent and there was no clinical evidence of macular edema, the patient was kept under observation without treatment. Patients with RP are prone to develop chronic, low grade inflammation responses similar to the ones present in FHI. This association makes us believe that immunogenetic pathways involved in the degenerative process that leads to photoreceptor loss may become a target in the prevention and treatment of inflammatory complications in RP and disease progression. It also suggests FHI may be a triggered response predisposed by an unidentified genetic factor that may be related to genes affected in RP and thus be identified before irreversible complications such as glaucoma occur.

17 March 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
VMVirgilio Morales-Canton
Virgilio Morales-Canton
DMDaniela Meizner-Grezemkovsky
Daniela Meizner-Grezemkovsky
PBPablo Baquero-Ospina
Pablo Baquero-Ospina
NCNicolás Crim
Nicolás Crim
LWLihteh Wu
Lihteh Wu
In this paper, we compare the post-operative macular microvascular parameters (vascular density and foveal avascular zone) in eyes with refractory macular hole (MH) that underwent pars plana vitrectomy and autologous retinal transplant (ART) with the fellow unoperated eye. We conducted a retrospective case control study of six consecutive patients who underwent pars plana vitrectomy and ART with at least six months of post-operative follow-up. Pre-operatively, all eyes underwent SD-OCT (Spectral Domain Optical Coherence Tomography) examination. Post-operative OCT-A analyses included vascular density (VD) and the foveal avascular zone (FAZ) area. Six patients with a mean age of 63.7 ± 14.3 years were included. The mean follow-up was 24 months (range 6–30 months). The pre-operative BCVA (best-corrected visual acuity) was 0.99 ± 0.46 logMAR and 1.02 ± 0.23 logMAR at the last post-operative visit (p = 1.00). The mean MH diameter was 966 ± 620 µm. VD in the MH group was 28.1 ± 7.3% compared to 20.2 ± 2.9% in the fellow eyes group (p < 0.05). The mean post-operative FAZ area in the MH group was 109.8 ± 114.6 mm2 compared to 41.5 ± 10.4 mm2 in the control group (p < 0.05). In all six eyes, MH closure was obtained. The post-operative visual acuity did not improve after ART. Eyes with a closed MH showed a bigger FAZ with a higher VD compared to the fellow healthy eye.

26 July 2020 in medRxiv
Verified
Preprint
Open access
PDF file
ANAlejandro Noriega
Alejandro Noriega
DMDaniela Meizner
Daniela Meizner
DCDalia Camacho
Dalia Camacho
JEJennifer Enciso
Jennifer Enciso
HQHugo Quiroz-Mercado
Hugo Quiroz-Mercado
APAlex Pentland
Alex Pentland
Background: The automated screening of patients at risk of developing diabetic retinopathy (DR) represents an opportunity to improve their mid-term outcome, and lower the public expenditure associated with direct and indirect costs of common sight-threatening complications of diabetes. Objective: In the present study, we aim at developing and evaluating the performance of an automated deep learning–based system to classify retinal fundus images from international and Mexican patients, as referable and non-referable DR cases. In particular, we study the performance of the automated retina image analysis (ARIA) system under an independent scheme (i.e. only ARIA screening) and two assistive schemes (i.e., hybrid ARIA + ophthalmologist screening), using a web-based platform for remote image analysis. Methods: We ran a randomized controlled experiment where 17 ophthalmologists were asked to classify a series of retinal fundus images under three different conditions: 1) screening the fundus image by themselves ( solo ), 2) screening the fundus image after being exposed to the opinion of the ARIA system ( ARIA answer ), and 3) screening the fundus image after being exposed to the opinion of the ARIA system, as well as its level of confidence and an attention map highlighting the most important areas of interest in the image according to the ARIA system ( ARIA explanation ). The ophthalmologists’ opinion in each condition and the opinion of the ARIA system were compared against a gold standard generated by consulting and aggregating the opinion of three retina specialists for each fundus image. Results: The ARIA system was able to classify referable vs. non-referable cases with an area under the Receiver Operating Characteristic curve (AUROC), sensitivity, and specificity of 98%, 95.1% and 91.5% respectively, for international patient-cases; and an AUROC, sensitivity, and specificity of 98.3%, 95.2%, and 90% respectively for Mexican patient-cases. The results achieved on Mexican patient-cases outperformed the average performance of the 17 ophthalmologist participants of the study. We also find that the ARIA system can be useful as an assistive tool, as significant sensitivity improvements were observed in the experimental condition where participants were exposed to the answer of the ARIA system as a second opinion (93.3%), compared to the sensitivity of the condition where participants assessed the images independently (87.3%). Conclusions: These results demonstrate that both use cases of ARIA systems, independent and assistive , present a substantial opportunity for Latin American countries like Mexico towards an efficient expansion of monitoring capacity for the early detection of diabetes-related blindness.