Sergio Borrella Andrés

Mr. Sergio Borrella Andrés

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
SASergio Borrella Andrés
Sergio Borrella Andrés
IMIsabel Marqués-García
Isabel Marqués-García
MLMaría Orosia Lucha-López
María Orosia Lucha-López
PFPablo Fanlo-Mazas
Pablo Fanlo-Mazas
MSMar Hernández Secorún
Mar Hernández Secorún
CHCésar Hidalgo-García
César Hidalgo-García
Background. Cervical radiculopathy is defined as a disorder involving dysfunction of the cervical nerve roots characterised by pain radiating and/or loss of motor and sensory function towards the root affected. There is no consensus on a good definition of the term. In addition, the evidence regarding the effectiveness of manual therapy in radiculopathy is contradictory. Objective. To assess the effectiveness of manual therapy in improving pain, functional capacity, and range of motion in treating cervical radiculopathy with and without confirmation of altered nerve conduction. Methods. Systematic review of randomised clinical trials on cervical radiculopathy and manual therapy, in PubMed, Web of Science, Scopus, PEDro, and Cochrane Library Plus databases. The PRISMA checklist was followed. Methodological quality was evaluated using the PEDro scale and RoB 2.0. tool. Results. 17 clinical trials published in the past 10 years were selected. Manual therapy was effective in the treatment of symptoms related to cervical radiculopathy in all studies, regardless of the type of technique and dose applied. Conclusions. This systematic review did not establish which manual therapy techniques are the most effective for cervical radiculopathy with electrophysiological confirmation of altered nerve conduction. Without this confirmation, the application of manual therapy, regardless of the protocol applied and the manual therapy technique selected, appears to be effective in reducing chronic cervical pain and decreasing the index of cervical disability in cervical radiculopathy in the short term. However, it would be necessary to agree on a definition and diagnostic criteria of radiculopathy, as well as the definition and standardisation of manual techniques, to analyse the effectiveness of manual therapy in cervical radiculopathy in depth.

12 December 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
Jacobo Rodríguez-SanzJacobo Rodríguez-Sanz
Jacobo Rodríguez-Sanz
Sergi Rodriguez RodriguezSergi Rodriguez Rodriguez
Sergi Rodriguez Rodriguez
Carlos López-de-CelisCarlos López-de-Celis
Carlos López-de-Celis
MMMiguel Malo-Urriés
Miguel Malo-Urriés
SPSoledad Perez-Amodio
Soledad Perez-Amodio
MTMiguel Angel Mateos Timoneda
Miguel Angel Mateos Timoneda
Background: Percutaneous electrolysis is an invasive physical therapy technique that is receiving attention. The objective of this article is to evaluate the biological and cellular effects of percutaneous electrolysis and its influence on tissue healing processes. Methods. The search strategy performed in PubMed, Cochrane Library, and Web of Sciences databases resulted in a total of 25 studies. Once inclusion and exclusion criteria were applied, seven studies were finally included in this systematic review. The biological effects of percutaneous electrolysis were evaluated and grouped into pro-inflammatory and anti-inflammatory effects, cell death, and extracellular matrix and tissue remodeling effects. Results. Percutaneous electrolysis generates a significant pro-inflammatory increase in the chronic tendon condition of IL1β-6-18-1α-1rn, NLRP3, and M1 polymorphonuclear cells and increased expression of COX2, TNFα, Cxcl10, and TGFβ1 during the first 7 days. This inflammation is regulated as of day 13. A significant increase in cell death markers, such as LDH, Yo-Pro, cytochrome C, and Smac/Diablo markers, was observed during the first 7 days. Finally, a significant increase in markers Mmp9, VEGF, VEGFR, PPAR-γ/tubulin, and COL-I was observed in the extracellular matrix and tissue remodeling, and a decrease in COL-III was observed during the first 7 days. In the acute inflammatory injury condition, an increase in anti-inflammatory markers, such as IL-10-13, CCL1, and IkB, and a significant decrease in pro-inflammatory cytokines, such as IL-6-1β, CCL3-4-5, CCR5-8, NFkB, and TNFα, were observed during the first 7 days. Finally, a significant increase in VEGF, VEGFR, and PPAR-γ/tubulin markers in the extracellular matrix and tissue remodeling was observed for this condition during the first 7 days. Conclusions. Percutaneous electrolysis generates a controlled local pro-inflammatory effect in chronic conditions and regulates inflammation in inflammatory injuries (during the first 7 days). Electrolysis has short-term effects (0–7 days post) of cell death and controlled extracellular matrix destruction. Additionally, it facilitates subsequent healing by improving extracellular matrix synthesis starting from 7 days after application.

SASergio Borrella Andrés
Sergio Borrella Andrés
MMMiguel Malo-Urriés
Miguel Malo-Urriés
Albert Pérez-BellmuntAlbert Pérez-Bellmunt
Albert Pérez-Bellmunt
JAJose Luis Arias-Buría
Jose Luis Arias-Buría
Jacobo Rodríguez-SanzJacobo Rodríguez-Sanz
Jacobo Rodríguez-Sanz
Carlos López-de-CelisCarlos López-de-Celis
Carlos López-de-Celis
Percutaneous needle electrolysis (PNE) consists of the ultrasound-guided application of a galvanic electrical current through a solid filament needle. One proposed therapeutic mechanism for this intervention is a potential thermal effect. The aim of this study was to investigate if the application of PNE induces changes in temperature in different cadaveric musculoskeletal tissues. A repeated measure experimental cadaveric study was designed with 10 cryopreserved knees (5 men, 5 women). Sterile stainless-steel needles of 40 mm length and 0.30 mm caliber were used in this study. An ultrasound-guided needling puncture was performed in the targeted tissue (patellar tendon, infra-patellar fat, and vastus medialis muscle). Additionally, the tip of the needle was placed next to the thermometer sensor at the minimum possible distance without direct contact with it. The temperature differences before and after different applications were measured. The applications were: three applications for 3 s of 3 mA of intensity (3:3:3) when the tendon was the targeted tissue, three applications for 3 s of 1.5 mA of intensity (1.5:3:3) when the fat or muscle was the targeted tissue, and 24 s of 1 mA of intensity (1:24:1) in all tissues. No statistically significant Group*Time interactions were found in any tissue (tendon: F = 0.571, p = 0.459, ŋ2 = 0.03; fat pad: F = 0.093; p = 0.764, ŋ2 = 0.01; muscle: F = 0.681; p = 0.420, ŋ2 = 0.04). Overall, no changes in temperature were observed between both applications in the tendon (3:3:3 vs. 1:24:1) and fat/muscle (1.5:3:3 vs. 1:24:1) tissues. The application of two different percutaneous needle electrolysis protocols did not produce appreciable thermal changes in the tendon, fat, and muscle tissues of human cadavers. The results from the current cadaver study support that a thermal effect should not be considered as a mechanism of clinical action regardless of the targeted human tissue when applying percutaneous needle electrolysis since no changes in temperature after its application were observed.

15 October 2023 in Life
Verified
Journal Article
Open access
PDF file
JAJose Luis Arias-Buría
Jose Luis Arias-Buría
SASergio Borrella Andrés
Sergio Borrella Andrés
Jacobo Rodríguez-SanzJacobo Rodríguez-Sanz
Jacobo Rodríguez-Sanz
Carlos López-de-CelisCarlos López-de-Celis
Carlos López-de-Celis
MMMiguel Malo-Urriés
Miguel Malo-Urriés
IAIsabel Albarova-Corral
Isabel Albarova-Corral
For decades, needling interventions have been performed based on manual palpation and anatomic knowledge. The increasing use of real-time ultrasonography in clinical practice has improved the accuracy and safety of needling techniques. Although currently ultrasound-guided procedures are routinely used for patellar tendon pathology, e.g., during percutaneous electrolysis, the accuracy of these procedures is still unknown. This study used a cadaveric model to compare and evaluate both the accuracy and safety of ultrasound-guided and palpation-guided needling techniques for the patellar tendon. A total of five physical therapists performed a series of 20 needle insertion task each (n = 100), 10 insertions based on manual palpation (n = 50) and 10 insertions guided with ultrasound (n = 50) to place a needle along the interface between the patellar tendon and Hoffa’s fat pad. All procedures were performed on cryopreserved knee specimens. Distance to the targeted tissue, time of the procedure, accurate rate of insertions, number of passes, and unintentional punctured structures between both applications (with and without ultrasound guiding) were compared. The results revealed higher accuracy (100% vs. 80%), a lower distance from needle to the targeted tissue (0.25 ± 0.65 vs. 2.5 ± 1.9 mm), longer surface of contact with the needle (15.5 ± 6.65 vs. 4.7 ± 7.5 mm), and a lower frequency of patellar tendon puncture (16% vs. 52%, p < 0.001) with the ultrasound-guided procedure as opposed to palpation-guided one. Nevertheless, the ultrasound-guided procedure took longer (54.8 ± 26.8 vs. 23.75 ± 15.4 s) and required more passes (2.55 ± 1.9 vs. 1.5 ± 0.95) to be conducted than the palpation-guided procedure (all, p < 0.001). According to these findings, the accuracy of invasive procedures applied on the patellar tendon is higher when conducted with ultrasound guidance than when conducted just on manual palpation or anatomical landmark. These results suggest that ultrasound could improve the clinical application of invasive procedures at the fat-patellar tendon interface. Due to the anatomical features of the targeted tissue, some procedures require this precision, so the use of ultrasound is recommended.

30 May 2023 in Healthcare
Verified
Journal Article
Open access
PDF file
Carlos López-de-CelisCarlos López-de-Celis
Carlos López-de-Celis
César Fernandez-de-las-PeñasCésar Fernandez-de-las-Peñas
César Fernandez-de-las-Peñas
MMMiguel Malo-Urriés
Miguel Malo-Urriés
IAIsabel Albarova-Corral
Isabel Albarova-Corral
JAJose Luis Arias-Buría
Jose Luis Arias-Buría
SASergio Borrella Andrés
Sergio Borrella Andrés
Percutaneous electrical stimulation has been performed for years with only the assistance of anatomical landmarks. The development of real-time ultrasonography guidance has improved the precision and safety of these percutaneous interventions. Despite ultrasound-guided and palpation-guided procedures being performed routinely for targeting nerve tissues in the upper extremity, the precision and safety of these techniques are unknown. The aim of this cadaveric study was to determine and compare the precision and safety of ultrasound-guided versus palpation-guided needling procedure with and without the handpiece of the ulnar nerve on a cadaveric model. Five physical therapists performed a series of 20 needle insertion tasks each (n = 100), 10 palpation-guided (n = 50) and 10 ultrasound-guided (n = 50) on cryopreserved specimens. The purpose of the procedure was to place the needle in proximity to the ulnar nerve at the cubital tunnel. The distance to target, time performance, accurate rate, number of passes, and unintentional puncture of surrounding structures were compared. The ultrasound-guided procedure was associated with higher accuracy (66% vs. 96%), lower distance from needle to the target (0.48 ± 1.37 vs. 2.01 ± 2.41 mm), and a lower frequency of perineurium puncture (0% vs. 20%) when compared with the palpation-guided procedure. However, the ultrasound-guided procedure required more time (38.33 ± 23.19 vs. 24.57 ± 17.84 s) than the palpation-guided procedure (all, p < 0.001). Our results support the assumption that ultrasound guidance improves the accuracy of needling procedures on the ulnar nerve at the cubital tunnel when compared with palpation guidance.

Verified
Journal Article
Open access
PDF file
MMMiguel Malo-Urriés
Miguel Malo-Urriés
Jacobo Rodríguez-SanzJacobo Rodríguez-Sanz
Jacobo Rodríguez-Sanz
SASergio Borrella Andrés
Sergio Borrella Andrés
IRIzarbe Ríos-Asín
Izarbe Ríos-Asín
IAIsabel Albarova-Corral
Isabel Albarova-Corral
Carlos López-de-CelisCarlos López-de-Celis
Carlos López-de-Celis
Background/Objectives: Percutaneous electrolysis is a physiotherapeutic technique based on the application of galvanic current to induce structural and biochemical changes in musculoskeletal tissues. Although widely used in tendinopathies, its application in muscle tissue, particularly regarding optimal dosage, remains poorly understood. This study aimed to evaluate the dose-dependent effects of galvanic current on cadaveric muscle tissue (medial gastrocnemius) using quantitative ultrasound analysis, and to identify objective biomarkers to guide dosage. Methods: An experimental model was employed, applying galvanic current at varying intensities (0–10.0 mA) to 29 samples of cadaveric medial gastrocnemius. Quantitative ultrasound parameters were measured, including geometric and textural features. Correlation analyses and simple and multiple linear regressions were performed to assess the relationship between current intensity and ultrasound variables. Additionally, dose segmentation into three groups (low: 0–1.0 mA, medium: 1.0–4.0 mA, high: >4.0 mA) allowed for comparative statistical analysis using Kruskal–Wallis and post hoc Mann–Whitney U tests. Results: Significant dose–response relationships were observed in key ultrasound parameters, including A_Number, A_Area, A_Perimeter, and A_Contrast (p < 0.001). Regression analysis revealed that a combination of A_Area, A_Number, and A_Perimeter accounted for 66.7% of the variance in applied dose (R2 = 0.667, p < 0.001), leading to the creation of the predictive variable Muscle_Electrolysis_Dose. Comparative analysis confirmed significant differences between low-, medium-, and high-dose groups, particularly between lower and higher doses. Conclusions: Quantitative ultrasound effectively detects structural changes in muscle tissue following percutaneous electrolysis. The results support the development of objective, image-based criteria for optimizing galvanic current dosage, enhancing the precision and personalization of treatment.