zifang zhao

Dr. zifang zhao

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2021 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
MEMalin Silverå Ejneby
Malin Silverå Ejneby
MJMarie Jakešová
Marie Jakešová
JFJose J. Ferrero
Jose J. Ferrero
LMLudovico Migliaccio
Ludovico Migliaccio
ISIhor Sahalianov
Ihor Sahalianov
EGEric Daniel Głowacki
Eric Daniel Głowacki

8 April 2022 in Science Advances
Verified
Journal Article
Closed access
ZZzifang zhao
zifang zhao
GSGeorge D. Spyropoulos
George D. Spyropoulos
CCClaudia Cea
Claudia Cea
JGJennifer N. Gelinas
Jennifer N. Gelinas
DKDion Khodagholy
Dion Khodagholy
Implanted bioelectronic devices require data transmission through tissue, but ionic conductivity and inhomogeneity of this medium complicate conventional communication approaches. Here, we introduce ionic communication (IC) that uses ions to effectively propagate megahertz-range signals. We demonstrate that IC operates by generating and sensing electrical potential energy within polarizable media. IC was tuned to transmit across a range of biologically relevant tissue depths. The radius of propagation was controlled to enable multiline parallel communication, and it did not interfere with concurrent use of other bioelectronics. We created a fully implantable IC-based neural interface device that acquired and noninvasively transmitted neurophysiologic data from freely moving rodents over a period of weeks with stability sufficient for isolation of action potentials from individual neurons. IC is a biologically based data communication that establishes long-term, high-fidelity interactions across intact tissue.

28 July 2023 in Science Advances
Verified
Journal Article
Open access
Adam Armada-MoreiraAdam Armada-Moreira
Adam Armada-Moreira
ADAbdul Manan Dar
Abdul Manan Dar
ZZzifang zhao
zifang zhao
CCClaudia Cea
Claudia Cea
JGJennifer Gelinas
Jennifer Gelinas
ESEleni Stavrinidou
Eleni Stavrinidou
Electrical signals in plants are mediators of long-distance signaling and correlate with plant movements and responses to stress. These signals are studied with single surface electrodes that cannot resolve signal propagation and integration, thus impeding their decoding and link to function. Here, we developed a conformable multielectrode array based on organic electronics for large-scale and high-resolution plant electrophysiology. We performed precise spatiotemporal mapping of the action potential (AP) in Venus flytrap and found that the AP actively propagates through the tissue with constant speed and without strong directionality. We also found that spontaneously generated APs can originate from unstimulated hairs and that they correlate with trap movement. Last, we demonstrate that the Venus flytrap circuitry can be activated by cells other than the sensory hairs. Our work reveals key properties of the AP and establishes the capacity of organic bioelectronics for resolving electrical signaling in plants contributing to the mechanistic understanding of long-distance responses in plants.

10 May 2021 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
ZZzifang zhao
zifang zhao
CCClaudia Cea
Claudia Cea
JGJennifer N. Gelinas
Jennifer N. Gelinas
DKDion Khodagholy
Dion Khodagholy
Significance: We introduce a multiplex-then-amplify (MTA) scheme that requires only one amplifier per multiplexer, significantly reducing the number of components in multichannel acquisition systems while enabling arbitrary waveform stimulation independently on all channels. Based on this scheme, we developed a fully implantable, miniaturized, responsive embedded system that can acquire neural oscillations and action potentials using conformable conducting polymer-based electrodes as well as perform real-time onboard processing, low-latency arbitrary waveform stimulation, and local data storage. MTA devices enabled development of a protocol for suppression of pathologic coupling within an epileptic network. These devices will allow application of targeted high-spatiotemporal resolution responsive neurostimulation approaches to a variety of brain functions, broadening our ability to chronically modify neural networks in health and disease.

23 June 2025 in Nature Neuroscience
Verified
Journal Article
Open access
JFJose J. Ferrero
Jose J. Ferrero
AHAhnaf R. Hassan
Ahnaf R. Hassan
ZYZelin Yu
Zelin Yu
ZZzifang zhao
zifang zhao
LMLiang Ma
Liang Ma
JGJennifer N. Gelinas
Jennifer N. Gelinas
Interictal epileptiform discharges (IEDs) are expressed in epileptic networks and disrupt cognitive functions. It is unclear whether addressing IED-induced dysfunction could improve epilepsy outcomes, as most therapeutic approaches target seizures. We show, in a kindling model of progressive focal epilepsy, that IEDs produce pathological oscillatory coupling associated with prolonged, hypersynchronous neural spiking in synaptically connected cortex and expand the brain territory capable of generating IEDs. A similar relationship between IED-mediated oscillatory coupling and temporal organization of IEDs across brain regions was identified in human participants with refractory focal epilepsy. Spatiotemporally targeted closed-loop electrical stimulation triggered on hippocampal IED occurrence eliminated the abnormal cortical activity patterns, preventing the spread of the epileptic network and ameliorating long-term spatial memory deficits in rodents. These findings suggest that stimulation-based network interventions that normalize interictal dynamics may be an effective treatment of epilepsy and its comorbidities, with a low barrier to clinical translation.

15 January 2026 in Nature Sensors
Verified
Journal Article
Open access
PDF file
CYChi-Yuan Yang
Chi-Yuan Yang
ZZzifang zhao
zifang zhao
HWHan-Yan Wu
Han-Yan Wu
DGDace Gao
Dace Gao
JHJun-Da Huang
Jun-Da Huang
SFSimone Fabiano
Simone Fabiano
Event-based bioelectronic sensors enable real-time detection and modulation of neural activity. However, conventional silicon interfaces are rigid and energy intensive, whereas organic electrochemical neuron (OECN)-based sensors, though promising, have been limited by slow firing rates, high energy use and scalability challenges. Here we present an OECN-based sensor capable of rapid, energy-efficient neural signal detection for closed-loop neurostimulation. These event-driven sensors respond within ~1 ms and generate voltage pulses up to 1.1 kHz, covering the full bandwidth of mammalian neuronal activity (0.5–1,000 Hz) while consuming only ~40 pJ per spike. Accurate detection of hippocampal interictal epileptiform discharges is demonstrated. Integrated with microelectrodes, these OECN-based sensors enable closed-loop neuromodulation by delivering real-time stimulation to suppress pathological sleep spindle oscillations in vivo. Combining biorealistic operation with ultra-low energy use, OECN-based sensors are good candidates for the next generation of implantable bioelectronics in energy-constrained environments.