Wenkun Bai

Dr. Wenkun Bai


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2021 in Advanced Science
Verified
Journal Article
Open access
PDF file
ZMZheying Meng
Zheying Meng
YZYang Zhang
Yang Zhang
ESE Shen
E Shen
WLWei Li
Wei Li
YWYanjie Wang
Yanjie Wang
Yuanyi ZhengYuanyi Zheng
Yuanyi Zheng
The low delivery efficiency of nanoparticles to solid tumors greatly reduces the therapeutic efficacy and safety which is closely related to low permeability and poor distribution at tumor sites. In this work, an “intrinsic plus extrinsic superiority” administration strategy is proposed to dramatically enhance the mean delivery efficiency of nanoparticles in prostate cancer to 6.84% of injected dose, compared to 1.42% as the maximum in prostate cancer in the previously reported study. Specifically, the intrinsic superiority refers to the virus‐mimic surface topology of the nanoparticles for enhanced nano–bio interactions. Meanwhile, the extrinsic stimuli of microbubble‐assisted low‐frequency ultrasound is to enhance permeability of biological barriers and improve intratumor distribution. The enhanced intratumor enrichment can be verified by photoacoustic resonance imaging, fluorescence imaging, and magnetic resonance imaging in this multifunctional nanoplatform, which also facilitates excellent anticancer effect of photothermal treatment, photodynamic treatment, and sonodynamic treatment via combined laser and ultrasound irradiation. This study confirms the significant advance in nanoparticle accumulation in multiple tumor models, which provides an innovative delivery paradigm to improve intratumor accumulation of nanotherapeutics.

4 March 2014 in Oncology Letters
Verified
Journal Article
Open access
PDF file
ZSzhi shen
zhi shen
ESEnhui Shen
Enhui Shen
XDXue-Hong Diao
Xue-Hong Diao
WBWenkun Bai
Wenkun Bai
MZMin-Xia Zeng
Min-Xia Zeng
BHBing Hu
Bing Hu
The aim of the present study was to investigate the sonication effects of 21‑kHz ultrasound (US) with microbubbles (MBs) on the subcutaneous prostate tumors of nude mice. In total, 15 tumor‑bearing nude mice were divided into three groups: The control group, the low‑frequency US group and the US+MB group. The MBs used were from US contrast agent SonoVue. The parameters of the US were as follows: 21 kHz, 26 mW/cm2 and a 40% duty cycle (2 sec on, 3 sec off) for 3 min, once every other day for 2 weeks. Color Doppler flow imaging, hematoxylin and eosin (HE) staining, immunoblotting and transmission electron microscopy (TEM) were used to evaluate the results. Following 2 weeks of treatment, the blood flow signal disappeared in the US+MB group only, and the tumor size was smaller when compared with the control and US groups. For the immunoblotting, the intensity of cyclooxygenase‑2 and vascular endothelial growth factor in the US+MB group was lower compared with the other two groups. Tumor necrosis was present and the nucleus disappeared upon HE staining in the US+MB group. Upon TEM analysis, increased cytoplasmic vacuolation and dilatation of the perinuclear cisternae of the tumor cells were found in the US+MB group. In the control and US groups, the tumors had intact vascular endothelia and vessel lumens. However, lumen occlusion of the vessels was observed in the US+MB group. In conclusion, 21‑kHz low‑intensity US with MBs may result in vessel occlusion and growth inhibitory effects in the subcutaneous tumors of nude mice.

24 May 2024 in Heliyon
Verified
Journal Article
Open access
XLXiao Li
Xiao Li
ZSZiwei Sun
Ziwei Sun
WLWei Liu
Wei Liu
LSLianjie Sun
Lianjie Sun
JRJunyi Ren
Junyi Ren
WBWenkun Bai
Wenkun Bai
New quantitative ultrasound techniques can be used to quantify hepatic steatosis, including tissue attenuation imaging (TAI), tissue scatter -distribution imaging (TSI), and the hepatorenal index (HRI). However, the measurement norms and the effects of fasting on these measurements remain unclear. The present study performed a methodological exploration and investigated the reliability of these measurements. In total, 103 participants were prospectively recruited for ultrasonography and magnetic resonance imaging (MRI) scans. For the TAI and TSI data, the upper (2 cm), middle (4 cm) and lower (6 cm) areas determined according to the depth of the region of interest from the liver capsule, were sampled three times. Correlation analyses were performed to compare the measurements of TAI, TSI, and HRI with the controlled attenuation parameter (CAP) or MRI-proton density fat fraction (MRI-PDFF). Intra- and inter-operator repeatability was assessed using intraclass correlation coefficients. The effects of fasting on these measurements were then compared. The TAI and TSI measurements obtained from the upper and middle depths exhibited stronger correlations with the CAP measurements than those obtained from the lower depth. Specifically, the mean TAI had a significant positive correlation with MRI-PDFF (r = 0.753, P < 0.0001). TAI and TSI measurements exhibited excellent intra- (0.933 and 0.925, respectively) and inter- (0.896 and 0.766, respectively) examiner reliability. However, the correlation between HRI and CAP measurements was only 0.281, with no significant correlation with MRI-PDFF, and intra- and inter-examiner reproducibility of 0.458 and 0.343, respectively. Fasting did not affect these measurements. TAI and TSI measurements demonstrated good intra- and interobserver reliability and correlated well with CAP and MRI-PDFF measurements. However, in practice-based clinical applications, the sampling depth should be controlled within 2–4 cm of the hepatic capsule; no fasting is required before the examination.

19 July 2023 in Ultraschall in der Medizin - European Journal of Ultrasound
Verified
Journal Article
Open access
PDF file
WLWen Li
Wen Li
XLXiao Li
Xiao Li
ZKZhibin Kong
Zhibin Kong
BCBin Chen
Bin Chen
HZHongsheng Zhou
Hongsheng Zhou
Yuanyi ZhengYuanyi Zheng
Yuanyi Zheng
Purpose As a public health emergency of international concern, coronavirus disease 2019 (COVID-19) still lacks specific antiviral drugs, and symptomatic treatment is currently the mainstay. The overactivated inflammatory response in COVID-19 patients is associated with a high risk of critical illness or even death. Low-intensity pulsed ultrasound (LIPUS) can mitigate inflammation and inhibit edema formation. We aimed to investigate the efficacy of LIPUS therapy for COVID-19 pneumonia. Materials and Methods 62 patients were randomly assigned to a treatment group (LIPUS treatment area – Group 1; self-control area – Group 2) and an external control group (Group 3). The primary outcomes were the volume absorption rate (VAR) and the area absorption rate (AAR) of lung inflammation in CT images. Results After an average duration of treatment 7.2 days, there were significant differences in AAR and VAR between Group 1 and Group 2 (AAR 0.25 vs 0.12, p=0.013; VAR 0.35 vs 0.11, p=0.005), and between Group 1 and Group 3 (AAR 0.25 vs 0.11, p=0.047; VAR 0.35 vs 0.19, p=0.042). Neither AAR nor VAR was statistically different between Group 2 and Group 3. After treatment, C-reactive protein, interleukin-6, leukocyte, and fingertip arterial oxygen saturation (SaO2) improved in Group 1, while in Group 3 only fingertip SaO2 increased. Conclusion LIPUS therapy reduced lung inflammation and serum inflammatory factor levels in hospitalized COVID-19 patients, which might be a major advancement in COVID-19 pneumonia therapy.

9 June 2023 in Trials
Verified
Journal Article
Open access
PDF file
XLXiao Li
Xiao Li
WLWen Li
Wen Li
LSLianjie Sun
Lianjie Sun
JRJunyi Ren
Junyi Ren
YXYing Xu
Ying Xu
WBWenkun Bai
Wenkun Bai
Background: Viral pneumonia has always been a problem faced by clinicians because of its insidious onset, strong infectivity, and lack of effective drugs. Patients with advanced age or underlying diseases may experience more severe symptoms and are prone to severe ventilation dysfunction. Reducing pulmonary inflammation and improving clinical symptoms is the focus of current treatment. Low-intensity pulsed ultrasound (LIPUS) can mitigate inflammation and inhibit edema formation. We aimed to investigate the efficacy of therapeutic LIPUS in improving lung inflammation in hospitalized patients with viral pneumonia. Methods: Sixty eligible participants with clinically confirmed viral pneumonia will be assigned to either (1) intervention group (LIPUS stimulus), (2) control group (null stimulus), or (3) self-control group (LIPUS stimulated areas versus non-stimulated areas). The primary outcome will be the difference in the extent of absorption and dissipation of lung inflammation on computed tomography. Secondary outcomes include changes in lung inflammation on ultrasonography images, pulmonary function, blood gas analysis, fingertip arterial oxygen saturation, serum inflammatory factor levels, the sputum excretion volume, time to the disappearance of pulmonary rales, pneumonia status score, and course of pneumonia. Adverse events will be recorded. Discussion: This study is the first clinical study of the efficacy of therapeutic LIPUS in the treatment of viral pneumonia. Given that the current clinical recovery mainly depends on the body’s self-limiting and conventional symptomatic treatment, LIPUS, as a new therapy method, might be a major advance in the treatment of viral pneumonia. Trial registration: ChiCTR2200059550 Chinese Clinical Trial Registry, May 3, 2022.

1 March 2021 in Urology Case Reports
Verified
Journal Article
Open access
YFY. Fadil
Y. Fadil
WBWenkun Bai
Wenkun Bai
YCY. Chakir
Y. Chakir
DMDAKIR Mohamed
DAKIR Mohamed
ADA. Debbagh
A. Debbagh
RARachid Aboutaieb
Rachid Aboutaieb
Post-traumatic adrenal hematoma, which has rare but severe complications, is a difficult to diagnose condition. Only computed tomography, which is often performed systematically during lesional assessments of violent thoraco-abdominal trauma, can confirm the diagnosis. Symptoms are often masked by associated visceral or parietal lesions. Standard biological examinations are generally not very helpful. We will describe the case of a 47-year-old man who presented with a right adrenal hemorrhage following a road accident, for only associated lesion, a fracture of the middle arch of the first and 8th ribs, and the transverse process L1.