A new, highly accurate method of measurement of the gas flow velocity has been developed. The method employs the phenomenon of propagation of thermal waves in flowing gas. The probe consists of three thin wires. One of these is a hot wire and it is used to generate a thermal wave while the two remaining wires are used for wave detection. Since the phase shift of the wave between two points is proportional to the wave frequency, the flow velocity can be derived from the slope of the regression line. Signals from the wave detectors are sent via an analog to digital converter to the computer and processed. We report measurements of the laminar flow with the velocity between 30 and . The accuracy of the velocity measurements is about .
1 February 2013 in Review of Scientific Instruments
A new technique has been developed for determination of the very low gas flow velocity by means of the spectral analysis of the thermal waves. It is assumed that the transmitter signal is made of sine waves. By employing the Fourier analysis of the detector signals, the phase shifts of the relevant harmonic component of the frequency function were determined. The flow velocity has been obtained by a nonlinear regression analysis of the measured phase shifts values. This method allows for the flow of gas to be measured in a range from 5 to 500 cm/s.
This paper presents a method of measuring gas flow velocity based on the thermal time-of-flight method. The essence of the solution is an analysis of the time shift and the shape of voltage signals at the transmitter and at a temperature wave detector. The measurements used a probe composed of a wave transmitter and a detector, both in the form of thin tungsten wires. A rectangular signal was used at the wave transmitter. The time-of-flight of the wave was determined on the basis of the time shift of two selected characteristic points of the voltage waveform at the transmitter and the wave detector. To obtain the correct velocity indication, a correction in the form of a simple power function was applied. From the measurements performed, the relative uncertainty of the method was obtained, from approx. 4% of the measured value at an inflow velocity of 6.5 cm/s to 1% for an inflow velocity of 50 cm/s and higher.
This article presents an experimental stand for the generation of gas flows with very low velocities. The constant volume air flow was generated in the measurement area with the use of a Mariotte bottle and a water piston (water column in a tank). The air-flow velocity was determined from the change in the height of the water piston with time, which was measured via the difference between the pressure above the water surface and the pressure at the bottom of the water column. The tests were carried out in the mean velocity range of 0.35–66 cm/s. The five different velocities of air flowing out of the measurement pipe, measured with the particle image velocimetry method were compared with the results from the water piston method. The differences did not exceed 7%.