James C. Carr

Dr. James C. Carr


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2012 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
AUAsad A. Usman
Asad A. Usman
KTKirsi Taimen
Kirsi Taimen
MWMarie Wasielewski
Marie Wasielewski
JMJennifer McDonald
Jennifer McDonald
SSSaurabh Shah
Saurabh Shah
JCJames C. Carr
James C. Carr
Background—: Acute rejection is a major factor impacting survival in the first 12 months after cardiac transplantation. Transplant monitoring requires invasive techniques. Cardiac magnetic resonance (CMR), noninvasive testing, has been used in monitoring heart transplants. Prolonged T2 relaxation has been related to transplant edema and possibly rejection. We hypothesize that prolonged T2 reflects transplant rejection and that quantitative T2 mapping will concur with the pathological and clinical findings of acute rejection. Methods and Results—: Patients were recruited within the first year after transplantation. Biopsies were graded according to the International Society for Heart Lung Transplant system for cellular rejection with immunohistochemistry for humoral rejection. Rejection was also considered if patients presented with signs and symptoms of hemodynamic compromise without biopsy evidence of rejection who subsequently improved with treatment. Patients underwent a novel single-shot T2-prepared steady-state free precession 4-chamber and 3 short axis sequences and regions of interest were drawn overlying T2 maps by 2 independent blinded reviewers. A total of 74 (68 analyzable) CMRs T2 maps in 53 patients were performed. There were 4 cellular, 2 humoral, and 2 hemodynamic rejection cases. The average T2 relaxation time for grade 0R (n=46) and grade 1R (n=17) was 52.5±2.2 and 53.1±3.3 ms (mean±SD), respectively. The average T2 relaxation for grade 2R (n=3) was 59.6±3.1 ms and 3R (n=1) was 60.3 ms (all P value <0.05 compared with controls). The T2 average in humoral rejection cases (n=2) was 59.2±3.3 ms and the hemodynamic rejection (n=2) was 61.1±1.8 ms ( P <0.05 versus controls). The average T2 relaxation time for all-cause rejection versus no rejection is 60.1±2.1 versus 52.8±2.7 ms ( P <0.05). All rejection cases were rescanned 2.5 months after treatment and demonstrated T2 normalization with average of 51.4±1.6 ms. No difference was found in ventricular function between nonrejection and rejection patients, except in ventricular mass 107.8±10.3 versus 127.5±10.4 g ( P < 0.05). Conclusions—: Quantitative T2 mapping offers a novel noninvasive tool for transplant monitoring, and these initial findings suggest potential use in characterizing rejections. Given the limited numbers, a larger multi-institution study may help elucidate the benefits of T2 mapping as an adjunctive tool in routine monitoring of cardiac transplants.

1 January 2020 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
YHYuchi Han
Yuchi Han
TCTiffany Chen
Tiffany Chen
JKJennifer King
Jennifer King
CBChiara Bucciarelli-Ducci
Chiara Bucciarelli-Ducci
CDChristopher Dyke
Christopher Dyke
JCJames C. Carr
James C. Carr
The aim of this document is to provide general guidance and specific recommendations on the practice of cardiovascular magnetic resonance (CMR) in the era of the COVID-19 pandemic. There are two major considerations. First, continued urgent and semi-urgent care for the patients who have no known active COVID-19 should be provided in a safe manner for both patients and staff. Second, when necessary, CMR on patients with confirmed or suspected active COVID-19 should focus on the specific clinical question with an emphasis on myocardial function and tissue characterization while optimizing patient and staff safety.

1 January 2020 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
SKSebastian Kelle
Sebastian Kelle
CBChiara Bucciarelli-Ducci
Chiara Bucciarelli-Ducci
RJRobert M. Judd
Robert M. Judd
RKRaymond Y. Kwong
Raymond Y. Kwong
OSOrlando Simonetti
Orlando Simonetti
JCJames C. Carr
James C. Carr
The aim of this document is to provide specific recommendations on the use of cardiovascular magnetic resonance (CMR) protocols in the era of the COVID-19 pandemic. In patients without COVID-19, standard CMR protocols should be used based on clinical indication as usual. Protocols used in patients who have known / suspected active COVID-19 or post COVID-19 should be performed based on the specific clinical question with an emphasis on cardiac function and myocardial tissue characterization. Short and dedicated protocols are recommended.

1 February 2018 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
RKR. J. Kim
R. J. Kim
OSO. P. Simonetti
O. P. Simonetti
MWM. Westwood
M. Westwood
CKChristopher Kramer
Christopher Kramer
ANA. Narang
A. Narang
VFV. A. Ferrari
V. A. Ferrari
These “Guidelines for training in Cardiovascular Magnetic Resonance” were developed by the Certification Committee of the Society for Cardiovascular Magnetic Resonance (SCMR) and approved by the SCMR Board of Trustees.

25 October 2021 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
JCJohn W Cerne
John W Cerne
APAshitha Pathrose
Ashitha Pathrose
DGDaniel Z. Gordon
Daniel Z. Gordon
RSRoberto Sarnari
Roberto Sarnari
MVManik Veer
Manik Veer
JCJames C. Carr
James C. Carr

1 October 2007 in American Journal of Roentgenology
Verified
Journal Article
Closed access
IKIoannis Koktzoglou
Ioannis Koktzoglou
AKAnish Kirpalani
Anish Kirpalani
TCTimothy J. Carroll
Timothy J. Carroll
DLDebiao Li
Debiao Li
JCJames C. Carr
James C. Carr
OBJECTIVE. The purpose of this study was to compare the performance of 3D diffusion-prepared balanced steady-state free precession (SSFP) imaging with that of 3D contrast-enhanced MR angiography in evaluation of the thoracic aorta.MATERIALS AND METHODS. Twenty-one patients with indications for contrast-enhanced MR angiography and diffusion-prepared SSFP of the thoracic aorta were involved in this retrospective chart review study conducted with 1.5-T MRI. Two observers scored the quality of the contrast-enhanced MR angiographic and diffusion-prepared SSFP images on the basis of depicting the thoracic aorta. Image quality scores and diametric measurements of the aorta from both image sets were compared.RESULTS. Diametric measurements of the thoracic aorta showed a strong linear association (r = 0.971, p < 0.0001; regression line indifferent from line of equality, p < 0.05). The aortic root was better visualized with contrast-enhanced MR angiography (image quality score, 3.6 ± 0.9 vs 3.0 ± 0.8 of 5; p < 0.05...