Hai Liu

Dr. Hai Liu

Optical Transcevier, Cisco Systems (United States), San Jose, California, USA
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2025 in Nature Physics
Verified
Journal Article
Closed access
PDF file
SLSong Liu
Song Liu
PSPengcheng Sun
Pengcheng Sun
MWMingyue Wang
Mingyue Wang
YJYujie Jiang
Yujie Jiang
JLJiaqi Li
Jiaqi Li
Zuankai WangZuankai Wang
Zuankai Wang

1 June 2021 in Polymer
Verified
Journal Article
Closed access
SZShujun Zhao
Shujun Zhao
YYYutong Yang
Yutong Yang
FZFei Zhong
Fei Zhong
WNWenjuan Niu
Wenjuan Niu
YLYingshui Liu
Yingshui Liu
ZXZufeng Xiao
Zufeng Xiao

9 March 2023 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Open access
Hai LiuHai Liu
Hai Liu
MBMatin Barekatain
Matin Barekatain
ARAkash Roy
Akash Roy
SLSong Liu
Song Liu
YCYunqi Cao
Yunqi Cao
EKEun Sok Kim
Eun Sok Kim
This paper reports a highly sensitive piezoelectric microelectromechanical systems (MEMS) resonant microphone array (RMA) for detection and classification of wheezing in lung sounds. The RMA is composed of eight width-stepped cantilever resonant microphones with Mel-distributed resonance frequencies from 230 to 630 Hz, the main frequency range of wheezing. At the resonance frequencies, the unamplified sensitivities of the microphones in the RMA are between 86 and 265 mV Pa−1, while the signal-to-noise ratios (SNRs) for 1 Pa sound pressure are between 86.6 and 98.0 dBA. Over 200–650 Hz, the unamplified sensitivities are between 35 and 265 mV Pa−1, while the SNRs are between 79 and 98 dBA. Wheezing feature in lung sounds recorded by the RMA is more distinguishable than that recorded by a reference microphone with traditional flat sensitivity, and thus, the automatic classification accuracy of wheezing is higher with the lung sounds recorded by the RMA than with those by the reference microphone, when tested with deep learning algorithms on computer or with simple machine learning algorithms on low-power wireless chip set for wearable applications.

4 August 2020 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
Hai LiuHai Liu
Hai Liu
SLSong Liu
Song Liu
ASAnton A. Shkel
Anton A. Shkel
EKEun Sok Kim
Eun Sok Kim
This article presents active noise cancelation (ANC) based on MEMS resonant microphone array (RMA) which offers very high sensitivities (and thus very low noise floors) near resonance frequencies and also provides filtering in acoustic domain. The ANC is targeted to actively cancel out any sound between 5-9 kHz (above the speech range of 300 - 3,400 Hz). The ANC works best around the resonance frequencies of the resonant microphones where the sensitivities are high. The ANC has been implemented with analog inverter, digital phase compensator, digital adaptive filter, and deep learning, and shown to perform better with a digital adaptive filter for both RMA-based and flat-band-microphone-based ANC. At the same time, when the sound intensity over 5 - 9 kHz is low, RMA-based ANC with adaptive filter works the best among different approaches tested. Automatic speech recognition under different noises (of different intensity levels) has been tested with ANC. In all the tested cases, word error rate improves with ANC.

1 January 2010
Verified
Conference Paper
Closed access
Hai LiuHai Liu
Hai Liu
QCQi Chen
Qi Chen
ZZZhenqing Zhao
Zhenqing Zhao
QWQian Wang
Qian Wang
JZJianfeng Zeng
Jianfeng Zeng
JLJaisung Lee
Jaisung Lee
Au-Ag alloy wire is a low cost wire bonding solution instead of gold wire for IC packaging. Comparing with copper wire, Au-Ag wire has better productivity because it does not need protective gas and it is softer. The main issue of Au-Ag alloy wire bonding is its reliability in humidity environment. In present study, the bond parameters effect on PCT reliability was investigated. The correlation between the IMC profile and PCT lifetime was established. The IMC characteristic length was defined to express the relationship quantitatively. Meanwhile, The Au-Ag-Al IMC growth equation was obtained through HTS. It is found that the IMC growth rate is slower one order of magnitude than 99.99% gold wire.

20 October 2022 in Energy Conversion and Management
Verified
Journal Article
Closed access
SFShuyu Fan
Shuyu Fan
YTYongkui Tang
Yongkui Tang
LZLurui Zhao
Lurui Zhao
Hai LiuHai Liu
Hai Liu
YWYufeng Wang
Yufeng Wang
YCYunqi Cao
Yunqi Cao