SITTISAK JAMNAM

Dr. SITTISAK JAMNAM

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2024 in Construction and Building Materials
Verified
Journal Article
Closed access
PJPichthida Jittamaro
Pichthida Jittamaro
BMBuchit Maho
Buchit Maho
PPPhattharachai Pongsopha
Phattharachai Pongsopha
DNDuongruitai Nicomrat
Duongruitai Nicomrat
SJSITTISAK JAMNAM
SITTISAK JAMNAM
GSGritsada Sua-Iam
Gritsada Sua-Iam

11 July 2018 in Materials and Structures
Verified
Journal Article
Closed access
PDF file
Piti SukontasukkulPiti Sukontasukkul
Piti Sukontasukkul
SJSITTISAK JAMNAM
SITTISAK JAMNAM
MSManote Sappakittipakorn
Manote Sappakittipakorn
KFKazunori Fujikake
Kazunori Fujikake
PCPrinya Chindaprasirt
Prinya Chindaprasirt

4 August 2023 in Case Studies in Construction Materials
Verified
Journal Article
Open access
GSGritsada Sua-Iam
Gritsada Sua-Iam
SJSITTISAK JAMNAM
SITTISAK JAMNAM

2 December 2022 in Polymers
Verified
Journal Article
Open access
PDF file
SJSITTISAK JAMNAM
SITTISAK JAMNAM
Gritsada Sua-iamGritsada Sua-iam
Gritsada Sua-iam
BMBuchit Maho
Buchit Maho
SPSatharat Pianfuengfoo
Satharat Pianfuengfoo
MSManote Sappakittipakorn
Manote Sappakittipakorn
Piti SukontasukkulPiti Sukontasukkul
Piti Sukontasukkul
Concrete structures, when exposed to fire or high temperatures for a certain time, could suffer partial damage or complete structural failure. Passive fire-protective coating materials are an alternative way to prevent or delay damage to concrete structures resulting from fire. Superabsorbent polymer (SP) is a synthetic material known for its ability to absorb and retain a large volume of water within itself. With this unique property, the SP exhibits great potential for use as a passive fire protection material. Although several studies have been carried out to investigate the effect of SP as a surface coating material for fire protection, very few have been investigated on the potential use of SP mixed with mortar as a passive fire-protective layer. The objective of this study is to introduce the use of SP in plastering mortar as a fire-protective layer for concrete subjected to temperatures up to 800 °C. This study is divided into two parts: (1) investigating the properties of cement mortar mixed with SP at 0.5% (CONC/SP-0.5) and 1.0% (CONC/SP-1.0) by weight of cement, and (2) investigating the potential use of SP mortar as a plastering layer for concrete subject to high temperatures. The experimental results showed that the density and compressive strength of SP mortar decreases with increasing SP dosages. From the heat exposure results, SP mortar exhibited lower strength loss due to the ability to mitigate moisture through its interconnected pore system. As for the use of SP mortar as a plastering layer, the results demonstrated the concrete specimen plastered with SP mortar had a lower temperature at the interface and core than that plastered with plain mortar. This led to a reduced strength loss of 20.5% for CONC/SP-0.5 and 17.2% for CONC/SP-1.0.

3 February 2022 in The Journal of King Mongkut's University of Technology North Bangkok
Verified
Journal Article
Closed access
KCKomkorn Chaidachatorn
Komkorn Chaidachatorn
WJWeeraphan Jiammeepreecha
Weeraphan Jiammeepreecha
SJSITTISAK JAMNAM
SITTISAK JAMNAM

28 September 2022 in The Journal of King Mongkut's University of Technology North Bangkok
Verified
Journal Article
Closed access
ATApisit Techaphatthanakon
Apisit Techaphatthanakon
BMBuchit Maho
Buchit Maho
SJSITTISAK JAMNAM
SITTISAK JAMNAM
Piti SukontasukkulPiti Sukontasukkul
Piti Sukontasukkul
CRChesta Ruttanapun
Chesta Ruttanapun
PCPrinya Chindaprasirt
Prinya Chindaprasirt