Affordable 3D-printed tendon-driven prosthetic hands are a rising trend because of their availability and easy customization. Nevertheless, comparative studies about the functionality of this kind of prostheses are lacking. The tradeoff between the number of actuators and the grasping ability of prosthetic hands is a relevant issue in their design. The analysis of synergies among fingers is a common method used to reduce dimensionality without any significant loss of dexterity. Therefore, the purpose of this study is to assess the functionality and motion synergies of different tendon-driven hands using an able-bodied adaptor. The use of this adaptor to control the hands by means of the fingers of healthy subjects makes it possible to take advantage of the human brain control while obtaining the synergies directly from the artificial hand. Four artificial hands (IMMA, Limbitless, Dextrus v2.0, InMoov) were confronted with the Anthropomorphic Hand Assessment Protocol, quantifying functionality and human-like grasping. Three subjects performed the tests by means of a specially designed able-bodied adaptor that allows each tendon to be controlled by a different human finger. The tendon motions were registered, and correlation and principal component analyses were used to obtain the motion synergies. The grasping ability of the analyzed hands ranged between 48 and 57% with respect to that of the human hand, with the IMMA hand obtaining the highest score. The effect of the subject on the grasping ability score was found to be non-significant. For all the hands, the highest tendon-pair synergies were obtained for pairs of long fingers and were greater for adjacent fingers. The principal component analysis showed that, for all the hands, two principal components explained close to or more than 80% of the variance. Several factors, such as the friction coefficient of the hand contact surfaces, limitations on the underactuation, and impairments for a correct thumb opposition need to be improved in this type of prostheses to increase their grasping stability. The principal components obtained in this study provide useful information for the design of transmission or control systems to underactuate these hands.
In the present study, we propose a new actuation device and protocol for testing the grasping performance of low-cost 3D-printed hand prototypes. The actuation device is connected to the forearm of a healthy user and allows him to use his thumb and fingers to control any prototype moved by up to six tendons attached to this device. The protocol includes grasping actions on 24 different objects using eight typical grasp types to obtain a grasping ability score and information about the coordination of motion among the fingers. This study also presents a new design for a low-cost 3D-printed prosthetic hand, called the IMMA hand. Preliminary tests were performed with the IMMA hand and the actuation device on two subjects, using the protocol, to assess the validity of the device for the experimental evaluation of hand prototypes in early design stages. The analysis of the results of these tests shows that the coordination of motions among fingers is quite similar for both subjects, indicating a similar control of the artificial hand. Index and ring finger motions are highly correlated in over half of the grasp actions performed for both subjects.
1 July 2022 in Engineering Science and Technology, an International Journal
Anthropomorphic hands have received increasing research interest in the fields of robotics and prosthetics. But it is not yet clear how to evaluate their anthropomorphism. Similarity in the kinematic chain is essential to achieve both functionality and cosmesis. A few previous works have addressed the definition of anthropomorphism indexes, although they have some limitations in its definition. In this study, three different anthropomorphism indexes have been defined to compare the kinematic chain of artificial hands with that of the human hand. These indexes are based on the comparison of: (1) the parameters of the kinematic chain (dimensions, type of joints, orientations and ranges of motion), (2) the reachable workspace, and (3) common grasping postures. Five artificial hands with different degrees of anthropomorphism have been compared using the three Anthropomorphism Indexes of the Kinematic Chain (AIKC). The results show a high correlation between the first and third AIKC for the hands compared. The second AIKC presents much lower values than the other two, although they are higher for hands that combine abduction/adduction and flexion/extension movements in the kinematic chain of each finger. These indexes can be useful during the initial stage of designing artificial hands or evaluating their anthropomorphism.
The advent of 3D printing technologies has enabled the development of low-cost prosthetic underactuated hands, with cables working as tendons for flexion. Despite the particular relevance to human grasp, its conception in prosthetics is based on vague intuitions of the designers due to the lack of studies on its relevance to the functionality and performance of the device. In this work, some criteria for designers are provided regarding the carpometacarpal joint of the thumb in these devices. To this end, we studied four prosthetic hands of similar characteristics with the motion of abduction/adduction of the thumb resolved in three different ways: fixed at a certain abduction, coupled with the motion of flexion/extension, and actuated independently of the flexion/extension. The functionality and performance of the hands were assessed for the basic grasps using the Anthropomorphic Hand Assessment Protocol (AHAP) and a reduced version of the Southampton Hand Assessment Procedure (SHAP). As a general rule, it seems desirable that thumb adduction/abduction is performed independently of flexion/extension, although this adds one degree of control. If having this additional degree of control is beyond debate, coupled flexion/extension and adduction/abduction should be avoided in favour of the thumb having a fixed slight palmar abduction.