Aline Wolter

Dr. Aline Wolter


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2021 in Genes
Verified
Journal Article
Open access
PDF file
Ivonne BedeiIvonne Bedei
Ivonne Bedei
AWAline Wolter
Aline Wolter
AWAxel Weber
Axel Weber
FSFabrizio Signore
Fabrizio Signore
RARoland Axt-Fliedner
Roland Axt-Fliedner
In 1959, 63 years after the death of John Langdon Down, Jérôme Lejeune discovered trisomy 21 as the genetic reason for Down syndrome. Screening for Down syndrome has been applied since the 1960s by using maternal age as the risk parameter. Since then, several advances have been made. First trimester screening, combining maternal age, maternal serum parameters and ultrasound findings, emerged in the 1990s with a detection rate (DR) of around 90–95% and a false positive rate (FPR) of around 5%, also looking for trisomy 13 and 18. With the development of high-resolution ultrasound, around 50% of fetal anomalies are now detected in the first trimester. Non-invasive prenatal testing (NIPT) for trisomy 21, 13 and 18 is a highly efficient screening method and has been applied as a first-line or a contingent screening approach all over the world since 2012, in some countries without a systematic screening program. Concomitant with the rise in technology, the possibility of screening for other genetic conditions by analysis of cfDNA, such as sex chromosome anomalies (SCAs), rare autosomal anomalies (RATs) and microdeletions and duplications, is offered by different providers to an often not preselected population of pregnant women. Most of the research in the field is done by commercial providers, and some of the tests are on the market without validated data on test performance. This raises difficulties in the counseling process and makes it nearly impossible to obtain informed consent. In parallel with the advent of new screening technologies, an expansion of diagnostic methods has begun to be applied after invasive procedures. The karyotype has been the gold standard for decades. Chromosomal microarrays (CMAs) able to detect deletions and duplications on a submicroscopic level have replaced the conventional karyotyping in many countries. Sequencing methods such as whole exome sequencing (WES) and whole genome sequencing (WGS) tremendously amplify the diagnostic yield in fetuses with ultrasound anomalies.

14 February 2021 in Archives of Gynecology and Obstetrics
Verified
Journal Article
Open access
PDF file
AWAline Wolter
Aline Wolter
NMNatalia Markert
Natalia Markert
JWJan Sebastian Wolter
Jan Sebastian Wolter
AKAndrii Kurkevych
Andrii Kurkevych
JDJan Degenhardt
Jan Degenhardt
RARoland Axt-Fliedner
Roland Axt-Fliedner
Objectives: To analyse prenatal parameters predicting biventricular (BV) outcome in pulmonary atresia with intact ventricular septum/critical pulmonary stenosis (PAIVS/CPS). Methods: We evaluated 82 foetuses from 01/08 to 10/18 in 3 centres in intervals 1 (< 24 weeks), 2 (24–30 weeks) and 3 (> 30 weeks). Results: 61/82 (74.4%) were livebirths, 5 (8.2%) lost for follow-up, 3 (4.9%) had compassionate care leaving 53 (64.6% of the whole cohort and 86.9% of livebirths) with intention to treat. 9 died, 44/53 (83.0%) survived. 24/38 (63.2%) with information on postnatal outcome had BV outcome, 14 (36.8%) non-BV outcome (2 × 1.5 circulation). One with BV outcome had prenatal valvuloplasty. Best single parameter for BV outcome was tricuspid/mitral valve (TV/MV) ratio (AUC 0.93) in intervals 2 and 3 (AUC 0.92). Ventriculo-coronary-arterial communications (VCAC) were present in 11 (78.6%) in non-BV outcome group vs. 2 (8.3%) in BV outcome group (p < 0.001). Tricuspid insufficiency (TI)-Vmax > 2.5 m/s was present in BV outcome group in75.0% (18/24) vs. 14.3% (2/14) in non-BV outcome group. Including the most predictive markers (VCAC presence, TI- Vmax < 2.5 m/s, TV/MV ratio < cutoff) to a score, non-BV outcome was correctly predicted when > 1 criterion was fulfilled in all cases. After recently published criteria for foetal intervention, only 4/9 (44.4%) and 5/14 (35.7%) in our interval 2 + 3 with predicted non-BV outcome would have been candidates for intervention. Two (1 × intrauterine intervention) in interval 2, two in interval 3 reached BV outcome and one 1.5 circulation without intervention. Conclusion: TV/MV ratio as simple parameter has high predictive value. After our score, non-BV outcome was correctly predicted in all cases. Criteria for foetal intervention must further be evaluated.

5 August 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Ivonne BedeiIvonne Bedei
Ivonne Bedei
AGAlexander Graf
Alexander Graf
KGKarl-Philipp Gloning
Karl-Philipp Gloning
MMMatthias Meyer-Wittkopf
Matthias Meyer-Wittkopf
DWDaria Willner
Daria Willner
RARoland Axt-Fliedner
Roland Axt-Fliedner
Mirror syndrome is a rare and serious maternal condition associated with immune and non-immune fetal hydrops after 16 weeks of gestational age. Subjacent conditions associated with fetal hydrops may carry different risks for Mirror syndrome. Fetuses with Turner syndrome are frequently found to be hydropic on ultrasound. We designed a retrospective multicenter study to evaluate the risk for Mirror syndrome among pregnancies complicated with Turner syndrome and fetal hydrops. Data were extracted from a questionnaire sent to specialists in maternal fetal medicine in Germany. Out of 758 cases, 138 fulfilled our inclusion criteria and were included in the analysis. Of the included 138, 66 presented with persisting hydrops at or after 16 weeks. The frequency of placental hydrops/placentomegaly was rather low (8.1%). Of note, no Mirror syndrome was observed in our study cohort. We propose that the risk of this pregnancy complication varies according to the subjacent cause of fetal hydrops. In Turner syndrome, the risk for Mirror syndrome is lower than that reported in the literature. Our observations are relevant for clinical management and parental counseling.

Verified
Journal Article
Open access
PDF file
MMMarios Mamalis
Marios Mamalis
TKTamara Koehler
Tamara Koehler
Ivonne BedeiIvonne Bedei
Ivonne Bedei
AWAline Wolter
Aline Wolter
JSJohanna Schenk
Johanna Schenk
RARoland Axt-Fliedner
Roland Axt-Fliedner
Objective: In fetuses with suspicion of congenital heart disease (CHD), assessment by segmental fetal echocardiography is of great importance. This study sought to examine the concordance of expert fetal echocardiography and postnatal MRI of the heart at a high-volume paediatric heart centre. Methods: The data of two hundred forty-two fetuses have been gathered under the condition of full pre- and postnatal and the presence of a pre- and postnatal diagnosis of CHD. The haemodynamically leading diagnosis was determined for each test person and was then sorted into diagnostic groups. The diagnoses and diagnostic groups were used for the comparison of diagnostic accuracy in fetal echocardiography. Results: All comparisons between the diagnostic methods for detection of congenital heart disease showed an “almost perfect” (Cohen’s Kappa > 0.9) strength of agreement for the diagnostic groups. The diagnosis made by prenatal echocardiography showed a sensitivity of 90–100%, a specificity and a negative predictive value of 97–100%, and a positive predictive value of 85–100%. The diagnostic congruence resulted in an “almost perfect” strength of agreement for all evaluated diagnoses (transposition of great arteries, double outlet right ventricle, hypoplastic left heart, tetralogy of Fallot, atrioventricular septal defect). An agreement of Cohen’s Kappa > 0.9 was achieved for all groups, with exception of the diagnosis of double outlet right ventricle (0.8) in prenatal echocardiography compared to postnatal echocardiography. This study came to the result of a sensitivity of 88–100%, a specificity and negative predictive value of 97–100%, and a positive predictive value of 84–100%. The performance of cardiac magnetic resonance imaging (MRI) as an additional measure to echocardiography had an added value in the description of the malposition of the great arteries when diagnosed with double outlet right ventricle and in the detailed description of the anatomy of the lung circulation. Conclusions: Prenatal echocardiography could be shown to be a reliable method for detection of congenital heart disease when regarding the slightly lower accuracy of diagnosis for double outlet right ventricle and right heart anomalies. Furthermore, the impact of examiner experience and the consideration of follow-up examinations for further improvement of diagnosis accuracy may not be underestimated. The main advantage of an additional MRI is the possibility to obtain a detailed anatomic description of the blood vessels of the lung and the outflow tract. The conduction of further studies that include false-negative and false-positive cases, and studies that are not set within the high-risk-group, as well as studies in a less specialized setting, would allow the completion and investigation of possible differences and discrepancies when comparing the results that have been obtained in this study.

2 September 2015 in Ultraschall in der Medizin - European Journal of Ultrasound
Verified
Journal Article
Closed access
PDF file
JDJan Degenhardt
Jan Degenhardt
MRMeike Reinold
Meike Reinold
CEChristian Enzensberger
Christian Enzensberger
AWAline Wolter
Aline Wolter
AKAndrea Kawecki
Andrea Kawecki
RARoland Axt-Fliedner
Roland Axt-Fliedner
Purpose To evaluate pre- and post-procedure myocardial function in monochorionic twins with TTTS who underwent laser ablation of placental anastomoses using pulsed wave tissue Doppler imaging (pw TDI). Materials and Methods 20 monochorionic twin gestations with TTTS were included and underwent laser ablation at our center between 2011 and 2014. Prior to and after the intervention, cardiac function was assessed by measuring the mitral annular plane systolic excursion (MAPSE), the tricuspid annular plane systolic excursion (TAPSE), Tei index, isovolumetric contraction time (ICT), ejection time (ET), isovolumetric relaxation time (IRT) for the left ventricle in pulsed wave Doppler (pw D) ultrasound as well as ICT, ET, IRT and Tei index in pw TDI for the left and right ventricle. E-, A-, E´- and A´-wave peak velocity and the systolic downward motion (S´) were measured for both ventricles and the E/A, E/E´ and E´/A´ ratios were calculated. In a mean of 1.3 (SD 0.6) days after laser ablation, this measurement protocol was repeated. Results Pre-intervention recipients had longer ICT, ET and IRT in pw D and pw TDI compared to donors not reaching statistical significance for most parameters. Statistically significant were prolonged ICT in pw D (p 0.01) and ET (p 0.01) in pw TDI in recipients. In donor fetuses preoperative myocardial function did not differ significantly from postoperative myocardial function except in increased left ventricular ejection time of the left ventricle in pw TDI (p 0.04) and an increased E´/A´ratio (p 0.01). After laser coagulation, myocardial function was slightly altered in recipients as ICT and IRT shortened and Tei indices decreased but only reaching statistical significance in shortened IRTs in pw TDI for both ventricles. Conclusion Laser ablation of placental anastomoses in TTTS might influence myocardial function in the postoperative period. Shortened IRT intervals may reflect an improvement of diastolic function in recipients.

17 February 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Ivonne BedeiIvonne Bedei
Ivonne Bedei
DKDavid Knieß
David Knieß
KCKeil Corinna
Keil Corinna
AWAline Wolter
Aline Wolter
JSJohanna Schenk
Johanna Schenk
RARoland Axt-Fliedner
Roland Axt-Fliedner
Background: The fetuses of pregnant women affected by anti-Ro/anti-La antibodies are at risk of developing complete atrioventricular heart block (CAVB) and other potentially life-threatening cardiac affections. CAVB can develop in less than 24 h. Treatment with anti-inflammatory drugs and immunoglobulins (IVIG) can restore the normal rhythm if applied in the transition period. Routine weekly echocardiography, as often recommended, will rarely detect emergent AVB. The surveillance of these pregnancies is controversial. Home-monitoring using a hand-held Doppler is a promising new approach. Methods: To obtain an overview of the current practice in Germany, we developed a web-based survey sent by the DEGUM (German Society of Ultrasound in Medicine) to ultrasound specialists. With the intention to evaluate practicability of home-monitoring, we instructed at-risk pregnant women to use a hand-held Doppler in the vulnerable period between 18 and 26 weeks at our university center. Results: There are trends but no clear consensus on surveillance, prophylaxis, and treatment of anti-Ro/La positive pregnant between specialists in Germany. Currently most experts do not offer home-monitoring but have a positive attitude towards its prospective use. Intensified fetal monitoring using a hand-held Doppler is feasible for pregnant women at risk and does not lead to frequent and unnecessary contact with the center. Conclusion: Evidence-based guidelines are needed to optimize the care of anti-Ro/La-positive pregnant women. Individual risk stratification could help pregnancy care of women at risk and is welcmed by most experts. Hand-held doppler monitoring is accepted by patients and prenatal medicine specialists as an option for intensified monitoring and can be included in an algorithm for surveillance.