Multiple insulated gate bipolar transistor (IGBT) open-circuit faults severely affect the reliable operation of modular multilevel converters (MMCs). The existing literatures have not provided an effective diagnosis algorithm for MMCs when multiple IGBT open-circuit faults simultaneously appear in one arm. This paper presents a diagnosis strategy to handle that condition. Fault detection and estimation of the faulty submodule (SM) number is implemented by checking the value of the arm voltage error. The faulty SMs are located by observing when the transition of their switching functions leads to an obvious change of the arm voltage error. Meanwhile, the errors between the measured and predicted capacitor voltages are utilized to accelerate the localization. All of the faulty SMs can be quickly located one by one within several control cycles by using the proposed localization method. Simulation and experimental results demonstrate the validity of the proposed diagnosis strategy.
23 August 2018 in IEEE Transactions on Power Electronics
The grounding of low frequency distribution transformer is a critical concern which ensures the proper operation and protection of the distribution system. The power electronic transformer (PET), as a future alternative of low frequency distribution transformer, also needs to consider the grounding. This paper is studying the operation of PET with arc suppression coil(ASC) grounding in the Y-connected medium-voltage(MV) stage. The study focus on two aspects: 1. The MV stage current stress brought by ASC is analyzed and a negative sequence current compensation method is proposed to reduce the MV stage current stress; 2. The ASC impedance adjustment range that MV stage can provide is analyzed and a virtual impedance method is proposed to achieve this adjustment. The effectiveness of the proposed ASC-PET as well as its control strategy is verified by both simulation and experiment results.
19 June 2019 in IEEE Transactions on Industrial Electronics
This paper first analyzes the effect of the level-increased nearest level modulation (NLM) to the circulating current of the modular multilevel converter (MMC). The total inserted submodule (SM) number in one phase-leg of the MMC is variable using the level-increased NLM, which can significantly increase the peak-to-peak value of the circulating harmonic currents. Then a circulating harmonic currents suppression method is proposed by applying deadbeat control for the MMC with level-increased NLM. Compared with the existing direct circulating current control approaches for the MMC, the proposed method presents specific extension and adjustment principle of the total inserted SM number. Therefore, the proposed method can improve the dynamic control performance and handle large circulating harmonic currents at steady state. And it can well coordinate the modulation and circulating harmonic currents suppression stages to avoid disturbing the ac-side output voltage while regulating the circulating current. The effectiveness of the proposed method is evaluated by a single-phase industrial-level simulated MMC system and a laboratory experimental platform.
21 November 2018 in IEEE Transactions on Power Electronics
In computer science, consensus theory has been studied for decades. “Consensus” in a multi-agent system means reaching an agreement regarding a certain quantity of interest. The modular multilevel converter (MMC) is a promising topology for medium-and high-power applications owing to its salient features. In MMC operation, one key point is to regulate the capacitor voltage of each submodule (SM). SMs in MMCs are interconnected both physically and via a control system, and these SMs can be regarded as a multi-agent system, with the control objective of regulating their capacitor voltages, which could formulate a consensus problem. In this paper, through mathematical derivation, it is found that individual capacitor voltage regulation control of phase-shifted-carrier pulse-width modulation (PSC-PWM) MMC is one special case of consensus theory. Then based on consensus theory, the influence of different communication structures on the MMC voltage regulation performance is discussed. The analysis proves that the exiting one has the highest rate of convergence. The impact of current-tracking dynamics on consensus-based interpretation is also analyzed. In addition, the proportional relationship between the rate of convergence and the P controller parameter is also justified. Experiments on a seven-level down-scaled prototype are conducted to confirm the analysis.