Emiel Kruisdijk

Dr. Emiel Kruisdijk

TU Delft, Delft University of Technology, Delft, The Netherlands

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in Applied Geochemistry
Verified
Journal Article
Open access
EKEmiel Kruisdijk
Emiel Kruisdijk
BBBoris M. van Breukelen
Boris M. van Breukelen

6 August 2022 in Science of The Total Environment
Verified
Journal Article
Open access
EKEmiel Kruisdijk
Emiel Kruisdijk
CECarina Eisfeld
Carina Eisfeld
PSPieter J. Stuyfzand
Pieter J. Stuyfzand
BBBoris M. van Breukelen
Boris M. van Breukelen
An aquifer storage transfer and recovery (ASTR) system was studied in which tile drainage water (TDW) was injected with relatively high NO3 (about 14 mg/L) concentrations originating from fertilizers. Here we present the evolution of denitrification kinetics at 6 different depths in the aquifer before, and during ASTR operation. First-order denitrification rate constants increased over time before and during the first days of ASTR operation, likely due to microbial adaptation of the native bacterial community and/or bioaugmentation of the aquifer by denitrifying bacteria present in injected TDW. Push-pull tests were performed in the native aquifer before ASTR operation. Obtained first-order denitrification rate constants were negligible (0.00-0.03 d-1) at the start, but increased to 0.17-0.83 d-1 after a lag-phase of about 6 days. During the first days of ASTR operation in autumn 2019, the arrival of injected TDW was studied at 2.5 m distance from the injection well. First-order denitrification rate constants increased again over time (maximum >1 d-1). Three storage periods without injection were monitored in winter 2019, fall 2020, and spring 2021 during ASTR operation. First-order rate constants ranged between 0.12 and 0.61 d-1. Denitrification coupled to pyrite oxidation occurred at all depths, but other oxidation processes were indicated as well. NO3 concentration trends resembled Monod kinetics but were fitted also to a first-order decay rate model to facilitate comparison. Rate constants during the storage periods were substantially lower than during injection, probably due to a reduction in the exchange rate between aquifer solid phases and injected water during the stagnant conditions. Denitrification rate constants deviated maximally a factor 5 over time and depth for all in-situ measurement approaches after the lag-phase. The combination of these in-situ approaches enabled to obtain more detailed insights in the evolution of denitrification kinetics during AS(T)R.

7 June 2022 in Water Research
Verified
Journal Article
Open access
CECarina Eisfeld
Carina Eisfeld
JSJack F. Schijven
Jack F. Schijven
JWJan Van der Wolf
Jan Van der Wolf
GMGertjan Medema
Gertjan Medema
EKEmiel Kruisdijk
Emiel Kruisdijk
BBBoris M. van Breukelen
Boris M. van Breukelen
Irrigation with surface water carrying plant pathogens poses a risk for agriculture. Managed aquifer recharge enhances fresh water availability while simultaneously it may reduce the risk of plant diseases by removal of pathogens during aquifer passage. We compared the transport of three plant pathogenic bacteria with Escherichia coli WR1 as reference strain in saturated laboratory column experiments filled with quartz sand, or sandy aquifer sediments. E. coli showed the highest removal, followed by Pectobacterium carotovorum, Dickeya solani and Ralstonia solanacearum. Bacterial and non-reactive tracer breakthrough curves were fitted with Hydrus-1D and compared with colloid filtration theory (CFT). Bacterial attachment to fine and medium aquifer sand under anoxic conditions was highest with attachment rates of max. katt1 = 765 day-1 and 355 day-1, respectively. Attachment was the least to quartz sand under oxic conditions (katt1 = 61 day-1). In CFT, sticking efficiencies were higher in aquifer than in quartz sand but there was no differentiation between fine and medium aquifer sand. Overall removal ranged between < 6.8 log10 m-1 in quartz and up to 40 log10 m-1 in fine aquifer sand. Oxygenation of the anoxic aquifer sediments for two weeks with oxic influent water decreased the removal. The results highlight the potential of natural sand filtration to sufficiently remove plant pathogenic bacteria during aquifer storage.

25 April 2022 in Journal of Contaminant Hydrology
Verified
Journal Article
Open access
EKEmiel Kruisdijk
Emiel Kruisdijk
FZFrederik Zietzschmann
Frederik Zietzschmann
PSPieter J. Stuyfzand
Pieter J. Stuyfzand
BBBoris M. van Breukelen
Boris M. van Breukelen
A field injection experiment was performed in an anoxic sandy aquifer over 6 days to assess sorption characteristics of 7 commonly applied pesticides in agriculture and 2 frequently detected metabolites. Pesticide use changed considerably in the last decades, and there is insufficient knowledge of the fate of currently used pesticides in aquifers. Injected water arrival was monitored at 6 depth intervals of 1 m ranging from 11.4 to 32.2 m-below surface level with varying organic carbon contents (0.057-0.91%d.w.) to examine intra-aquifer variations in sorption. Observed pesticide concentrations were fit using a non-linear least squares routine to an advection-dispersion equation, from which retardation factors (R) were obtained. Pesticide degradation did not significantly influence the simulated R during the experiment. We observed that bentazon and cycloxydim were most mobile with R < 1.1 at all depths. Desphenyl chloridazon, methyl desphenyl chloridazon, and imidacloprid were, on average, less mobile, with maximum R of 1.5. Boscalid, chloridazon, fluopyram, and flutolanil showed a larger range of R, and R > 2.0 were observed in the shallowest part of the aquifer. Largest R were observed at the top of the aquifer and decreased with depth. Koc values varied similarly, which indicates that sorption is not only influenced by sedimentary organic matter (SOM) content but also by its sorption reactivity. Obtained sorption parameters were substantially lower than reported in a widely used pesticide sorption database, which suggests that sorption parameters are influenced by methodological differences and variations in the sorption reactivity of SOM. The large intra-aquifer variations in pesticide sorption highlights that aquifer heterogeneity should be considered in groundwater risk assessments.

9 February 2023 in Hydrogeology Journal
Verified
Journal Article
Open access
PDF file
EKEmiel Kruisdijk
Emiel Kruisdijk
JRJulian F. Ros
Julian F. Ros
DGDevanita Ghosh
Devanita Ghosh
MBMaren Brehme
Maren Brehme
PSPieter J. Stuyfzand
Pieter J. Stuyfzand
BBBoris M. van Breukelen
Boris M. van Breukelen
Well clogging was studied at an aquifer storage transfer and recovery (ASTR) site used to secure freshwater supply for a flower bulb farm. Tile drainage water (TDW) was collected from a 10-ha parcel, stored in a sandy brackish coastal aquifer via well injection in wet periods, and reused during dry periods. This ASTR application has been susceptible to clogging, as the TDW composition largely exceeded most clogging mitigation guidelines. TDW pretreatment by sand filtration did not cause substantial clogging at a smaller ASR site (2 ha) at the same farm. In the current (10 ha) system, sand filtration was substituted by 40-μm disc filters to lower costs (by 10,000–30,000 Euro) and reduce space (by 50–100 m2). This measure treated TDW insufficiently and injection wells rapidly clogged. Chemical, biological, and physical clogging occurred, as observed from elemental, organic carbon, 16S rRNA, and grain-size distribution analyses of the clogging material. Physical clogging by particles was the main cause, based on the strong relation between injected turbidity load and normalized well injectivity. Periodical backflushing of injection wells improved operation, although the disc filters clogged when the turbidity increased (up to 165 NTU) during a severe rainfall event (44 mm in 3 days). Automated periodical backflushing, together with regulating the maximum turbidity (<20 NTU) of the TDW, protected ASTR operation, but reduced the injected TDW volume by ~20–25%. The studied clogging-prevention measures collectively are only viable as an alternative for sand filtration when the injected volume remains sufficient to secure the farmer’s needs for irrigation.

24 September 2024 in Water Research
Verified
Journal Article
Open access
EKEmiel Kruisdijk
Emiel Kruisdijk
BBBoris M. van Breukelen
Boris M. van Breukelen
DHDoris van Halem
Doris van Halem
Iron (Fe2+), manganese (Mn2+), and ammonium (NH4+) oxidation processes were studied in three single media and three dual media full-scale rapid sand filters (RSFs) using reactive transport modelling (RTM) in PHREEQC and parameter estimation using PEST. Here, we present the insights gained into the spatial distribution of Fe and Mn mineral coatings in RSFs and its influence on the oxidation sequence and rates. Fe2+ and Mn2+ oxidation predominantly occurred simultaneously in the RSFs, contrary to the expected sequential oxidation based on Gibbs free energy calculations. During backwashing, RSF grains become fully mixed, which initiates heterogeneous Mn2+ oxidation on Mn-coated grains that end up in the top layer. The resulting grains have a mixed Fe/Mn mineral coating, which is limiting heterogeneous Mn2+ oxidation due to the limited Mn mineral surface available. Mixed coatings did not seem to affect Fe2+ oxidation rates, instead oxidation rates were increasing at lower pH. We found that RSFs can be designed to spatially separate Fe2+ and Mn2+ oxidation, which results in optimal conditions for Mn2+ oxidation. The RSF needs to consist of two layers with varying density to inhibit mixing and complete Fe2+ oxidation should occur in the top layer. The developed RTM can be used to estimate the depth at which Fe2+ oxidation is complete, and thus the ideal intersection depth of the two layers. A novel perspective is provided on how mineral coating distribution in single and dual media filters influence removal rates and the sequence of oxidation, which contributes to the design of more efficient groundwater filters.