Feng Zhang

Dr. Feng Zhang

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2016 in IEEE Transactions on Human-Machine Systems
Verified
Journal Article
Closed access
FZFeng Zhang
Feng Zhang
ZHZeng-Guang Hou
Zeng-Guang Hou
LCLong Cheng
Long Cheng
WWWeiqun Wang
Weiqun Wang
YCYixiong Chen
Yixiong Chen
HWHongbo Wang
Hongbo Wang
In this paper, a robot, namely iLeg, is designed for the purpose of rehabilitation of patients with hemiplegia or paraplegia. The iLeg is composed of one reclining seat and two leg orthoses, and each leg orthosis has three degrees of freedom, which correspond to the hip, knee, and ankle. Based on this robotic system, two controllers, i.e., passive training controller and active training controller, are proposed. The former takes advantage of the proportional-integral control method to solve the trajectory tracking problem, and the latter employs the surface electromyography signals to achieve active training. Two simplified impedance controllers, i.e., damping-type velocity controller and spring-type position controller, are designed for active training. A perceptron neural network detects movement intentions. The performance of the controllers was investigated with one able-bodied male. The results showed that the leg orthosis tracked the predefined trajectory based on the passive training controller, with the error rates of 0.45%, 0.44%, and 0.27%, respectively, for the hip, knee, and ankle. The active training controller whose loop rate is 6.67 Hz can move the leg orthosis smoothly, and the average recognition error of the perceptron neural network is less than 5%.

20 December 2019 in IEEE Transactions on Systems, Man, and Cybernetics: Systems
Verified
Journal Article
Closed access
JZJiabin Zhang
Jiabin Zhang
ZZzhengtao zhang
zhengtao zhang
HSHu Su
Hu Su
WZWei Zou
Wei Zou
XGXinyi Gong
Xinyi Gong
FZFeng Zhang
Feng Zhang
This article focuses on automatic inspection for the commonly used component called spring-wire socket. An automatic inspection system is built that adopts an endoscope to improve the imaging quality. To detect the low contrast targets in complex background, we adopt the pipeline of Faster R-CNN but with several improvements. The improved network specifies the targets in the form of quadrangular bounding box as opposed to previous methods that specify them by rectangular bounding box. With the quadrangular representation, additional shape and pose information is provided and unexpected overlaps and background disturbance could be avoided. In the network, an eight-dimensional (8-D) vector is designed to represent the quadrangular bounding box followed by the improved anchor mechanism in the region proposal network. And also, a novel overlap score calculation method is proposed. On the basis of the detection result, rules arisen from expertise are provided to determine the quality of the component in which way automatic quality inspection could be accomplished. The superiority of our detection network over existing ones is sufficiently demonstrated with the detection result of irregular targets in images captured in the industrial scenario. Meanwhile, successful inspection result proves that the system meets the industrial requirements in terms of both accuracy and speed and thus is of practical significance to industrial applications.

1 January 2018 in International Journal of Robotics and Automation
Verified
Journal Article
Closed access
PDF file
政朱政 朱
政 朱
WZWei Zou
Wei Zou
QWQingbin Wang
Qingbin Wang
FZFeng Zhang
Feng Zhang
Aiming at the problem of tracking delay and large errors when conventional image-based visual servo is applied to tracking moving objects, a velocity compensation image-based visual servo controller is proposed for head-fixed oculomotor control in this paper, which covers saccade, smooth pursuit and vergence. The controller consists of a basic visual servo sub-controller and a velocity compensation sub-controller. The former is used to eliminate position error and the latter takes into account the target's velocity. Corresponding Jacobian matrixes are derived to implement the controller. At the same time, a novel adaptive gain is designed to boost the control law and continuous velocities are implemented to avoid abrupt changes. A simple but stable fixation point detection method is proposed to provide the input for the whole system. Extensive experiments are conducted and analysed in a real binocular platform implemented with off-the-shelf set-ups, which demonstrate the effectiveness of the proposed method.

1 January 2019 in International Journal of Robotics and Automation
Verified
Journal Article
Closed access
政朱政 朱
政 朱
WZWei Zou
Wei Zou
FZFeng Zhang
Feng Zhang

1 January 2023 in Machines
Verified
Journal Article
Open access
PDF file
TLTengyang Li
Tengyang Li
FZFeng Zhang
Feng Zhang
HYHuabin Yang
Huabin Yang
HLHuiyuan Luo
Huiyuan Luo
ZZzhengtao zhang
zhengtao zhang
In this paper, we propose a misalignment correct method and a particle detection algorithm to improve the accuracy in the quality inspection of the LCD module after the anisotropic conductive film (ACF) bonding. We use only one camera to acquire images of multiple positions in order to establish the transformation from the image space to the world coordinate. Our method can accurately determine the center of rotation of the carrier table and calculate the deviation of position and angle of the tested module. Compared to traditional ways that rely on multiple cameras to align the large-sized product, our method has the advantages of simple structure, low cost, and fast calibration process. The particle detection is performed after positioning all bumps of the bonded module. The gray morphology-based algorithm is developed to detect the extreme point of every particle and refine the particle result through blob analysis. This method reduces the over-checking rate and performs better on the detection precision for dense particles. We verify the effectiveness of our proposed methods in our experiments. The alignment error can be less than 0.05 mm, and the accuracy of the particle detection is 93% while the recall rate is 92.4%.

19 September 2026
Verified
Book Chapter
Closed access
PDF file
CXChaoran Xu
Chaoran Xu
CLchengkan lv
chengkan lv
QCQiyu Chen
Qiyu Chen
YCYunkang Cao
Yunkang Cao
FZFeng Zhang
Feng Zhang
ZZzhengtao zhang
zhengtao zhang