For cardiovascular disease prevention, statins alone or combined with ezetimibe have been recommended to achieve low-density lipoprotein cholesterol targets, but their effects on other lipids are less reported. This study was designed to examine lipid changes in subjects with ST-segment elevation myocardial infarction (STEMI) after two highly effective lipid-lowering therapies. Twenty patients with STEMI were randomized to be treated with rosuvastatin 20 mg QD or simvastatin 40 mg combined with ezetimibe 10 mg QD for 30 days. Fasting blood samples were collected on the first day (D1) and after 30 days (D30). Lipidomic analysis was performed using the Lipidyzer platform. Similar classic lipid profile was obtained in both groups of lipid-lowering therapies. However, differences with the lipidomic analysis were observed between D30 and D1 for most of the analyzed classes. Differences were noted with lipid-lowering therapies for lipids such as FA, LPC, PC, PE, CE, Cer, and SM, notably in patients treated with rosuvastatin. Correlation studies between classic lipid profiles and lipidomic results showed different information. These findings seem relevant, due to the involvement of these lipid classes in crucial mechanisms of atherosclerosis, and may account for residual cardiovascular risk.Randomized clinical trial: ClinicalTrials.gov, NCT02428374, registered on 28/09/2014.
An ultra-fast method for the simultaneous determination of heavy metals in Passiflora incarnata tea by capillary electrophoresis (CE) using a short-end injection combined with multivariate analysis was proposed. Separation was conducted by hydrodynamic injection (5 s at 0.5 psi) using the short-end injection procedure in a fused uncoated silica capillary (50 cm total length, 10.2 cm effective length, 50 µm i.d.) with separation time less than 2 min. An indirect UV detection at 214 nm was employed by using imidazole as a chromophore. The buffer used was 6 mmol/L hydroxybutyric acid (HIBA). The optimum conditions by full factorial with a central point were achieved by 18-crown-6 concentration (23.3 mmol L−1), voltage (+11.4 kV), methanol concentration (3.8%), and temperature (20 °C). The method showed good linearity (R2 > 0.998) for both Cd and Pb, inter-day precision of less than 14.49%, and an adequate limit of quantification only for Cd (LOQ < 0.5 µg mL−1 for Cd) based on the US Pharmacopeial Convention limit requirements for elemental impurities. After method validation, the method was applied to Passiflora incarnata tea samples from a local market. Furthermore, the developed method showed great potential for the determination of metals in other samples with proper sample preparation procedures.