Introduction: Wearable near-infrared spectroscopy (NIRS) can be used during dynamic exercise to reflect the balance of muscle oxygen delivery and uptake. This study describes the behaviour and reliability of postexercise reoxygenation with NIRS as a function of exercise intensity at four muscle sites during an incremental cycling test. We discuss physiological components of faster and slower reoxygenation kinetics in the context of sport science and clinical applications. We hypothesised that reoxygenation would be slower at higher intensity, and that locomotor muscles would be faster than accessory muscles. We quantified test-retest reliability and agreement for each site.Methods: Twenty-one trained cyclists performed two trials of an incremental cycling protocol with 5-min work stages and 1-min rest between stages. NIRS was recorded from the locomotor vastus lateralis and rectus femoris muscles, and accessory lumbar paraspinal and lateral deltoid muscles. Reoxygenation time course was analysed as the half-recovery time (HRT) from the end of work to half of the peak reoxygenation amplitude during rest. Coefficient of variability (CV) between participants, standard error of the measurement (SEM) within participants, and intraclass correlation coefficient (ICC) for test-retest reliability were evaluated at 50%, 75%, and 100% peak workloads. A linear mixed-effects model was used to compare differences between workloads and muscle sites.Results: HRT was slower with increasing workload in the VL, RF, and PS, but not DL. VL had the fastest reoxygenation (lowest HRT) across muscle sites at all workloads (HRT = 8, 12, 17 s at 50%, 75%, 100% workload, respectively). VL also had the greatest reliability and agreement. HRT was sequentially slower between muscle sites in the order of VL < RF < PS < DL, and reliability was lower than for the VL.Discussion: This study highlights the potential for using wearable NIRS on multiple muscle sites during exercise. Reoxygenation kinetics differ between local muscle sites with increasing intensity. Moderate-to-good reliability in the VL support its increasing use in sport science and clinical applications. Lower reliability in other muscle sites suggest they are not appropriate to be used alone, but may add information when combined to better reflect systemic intensity and fatigue during exercise at different intensities.
Background: A flow limitation in the iliac arteries (FLIA) in endurance athletes is notoriously difficult to diagnose with the currently available diagnostic tools. At present, a commonly used diagnostic measure is a decrease in ankle brachial index with flex hips (ABIFlexed) following a maximal effort exercise test. Near-infrared spectroscopy (NIRS) is a non-invasive technique that measures skeletal muscle oxygenation as reflected by the balance of O2 delivery from microvascular blood flow and O2 uptake by metabolic activity. Therefore, NIRS potentially serves as a novel technique for diagnosing FLIA. The purpose of this study is to compare the diagnostic accuracy of NIRS-derived absolute, amplitude, and kinetic variables in legs during and after a maximal exercise test with ABIFlexed. Methods: ABIFlexed and NIRS were studied in 33 healthy subjects and 201 patients with FLIA diagnosed with echo-Doppler. Results: After maximal exercise, NIRS kinetic variables, such as the half value time and mean response time, resulted in a range of 0.921 to 0.939 AUC for the diagnosis of FLIA when combined with ABIFlexed. Conversely, ABIFlexed measurements alone conferred significantly worse test characteristics (AUC 0.717, p < 0.001). Conclusions: NIRS may serve as a diagnostic adjunct in patients with possible FLIA.
The mechanisms of sex-based differences in the sensation of unsatisfied inspiration (UI) in healthy humans during exercise are poorly understood. We found that females who selected UI at peak exercise had worse dyspnea intensity ratings throughout exercise. Both sexes who selected UI at peak exercise also reported more distressing dyspnea qualities post exercise. Psychosocial factors appeared to influence male dyspnea perception, whereas smaller absolute lung volumes correlated with worse UI ratings in females.
Previous studies based on animal models have raised concerns about salbutamol use in ozone air pollution with regard to ozone related lung injury. We conducted a double‐blind, randomized, placebo‐controlled crossover study including 18 subjects diagnosed with EIB by a eucapnic voluntary hyperpnea (EVH) test. Participants completed 30 min of standardized moderate to vigorous exercise in four conditions: ozone plus salbutamol; room air plus salbutamol; ozone plus placebo medication; and room air plus placebo medication. Spirometry, fraction of exhaled nitric oxide, and symptoms were measured before, immediately after, 30 min after and 1 h after exercise. Measurements between the four conditions were compared using percent change from pre to post exercise. There was a statistically significant difference between the salbutamol and placebo medication groups for spirometric variables including FEV1 (Estimate = 6.3, 95% CI: 4.23–8.37, p < 0.001). No differences were observed between ozone and room air exposures. There were no significant differences in FeNO response between experimental conditions. We found that salbutamol improved pulmonary function in individuals with EIB when exercising in ozone and did not increase eosinophilic airway inflammation as indicated by FeNO. This evidence suggests that it is safe for people with EIB to continue to use salbutamol as prescribed when ozone levels are elevated.
Objective: To explore the combination of measuring muscle oxygenation with near-infrared spectroscopy (NIRS) and cycling power during provocative incremental exercise for the detection of iliac arterial blood flow limitation (IAFL) in an otherwise healthy, well-trained cyclist. Design: Case report and methodological pilot study. Setting: University research setting. Patient: A well-trained amateur competitive male cyclist, aged 31 years, presenting with symptoms consistent with IAFL, but in whom diagnostic imaging was equivocal. Interventions: Four ramp incremental cycling tests performed on separate days to exercise intolerance, in a randomized order, in either typical race position (RP) or modified upright position (UP). Main Outcome: A novel ratio of unilateral cycling power to NIRS-derived muscle oxygenation termed “power-deoxygenation factor” was measured during provocative incremental exercise and compared with other NIRS-derived measures of vascular responsiveness and performance outcomes across the 2 body position conditions. Results: The power–deoxygenation factor was able to show clinically important, progressive differences between the affected and unaffected limbs, coinciding with worsening performance impairments related to the body position that were not detected with traditional measures of vascular responsiveness taken after exercise. Conclusions: This method was used to detect bilateral differences consistent with IAFL in a cyclist where traditional diagnostic criteria were equivocal, but subsequent intraoperative findings confirmed the diagnosis. A similar screening test could be performed noninvasively and without requiring specialized medical care. Future work should investigate the validity and sensitivity of this methodology to improve the ability to identify and monitor athletes with IAFL.