The process of identifying the peak discharge using the rational method was introduced in the 1880s. This method is a simple procedure for determining the peak discharge derived from surface runoff flow. Therefore, this research modified a simple hydrological formulation (rational method) based on fieldwork and compared a numerical rainfall model to the relationship model by using the simulation parameters, namely rainfall, infiltration, land use, and stream for hydrological conditions. The novelty of this research is a modification of the theoretical formula (rational method) through the use of fieldwork factors to modify the run-off coefficient. The first scene-up was overlay mapping between land and land use shape files, while the scene-up sampling point was upstream and downstream. This was continued with the estimation curve number until a specific composite curve number was initiated. The rate of infiltration was determined using the Horton method to distinguish the soil type, while the Water Stage Data Logger Starter Kit 13" HOBO KIT-S-U20-04 was used to measure the water level, HEC HMS, and rating curve analysis. The relationships between the fieldwork data using hydrology analysis and modeling were then compared. The results showed that the maximum rainfall calculated and analyzed from the box-and-whisker plot was 140 mm in the year 2019. In addition, the infiltration rate at the upstream and downstream areas was 90 mm/hour and 26.4 mm/hour, or 30% out of the upstream area value. Finally, the estimations of the runoff coefficient were 0.60, 0.45, and 0.0133, while the discharges for the maximum rainfall intensity were observed at 405.7 m3/s, 304.3 m3/s, and 25 m3/s. The simulation using Hydrological Modelling HEC HMS 4.11 computed results of 0.1 m3/s and observed flow of 0.3 m3/s. Doi: 10.28991/HEF-2023-04-02-02 Full Text: PDF
1 March 2026 in IOP Conference Series: Earth and Environmental Science
Rational method and HEC-HMS (Hydrological Engineering Center-Hydrologic Modeling System) rainfall-runoff modelling are required to be calibrated, verified, and validated to determine peak flow. Therefore, this study aims to find C value using rational method. During the analysis, runoff coefficient was calculated based on rainfall data, land coverage, and water level data from an automatic water level recorder, which was used to evaluate the results in calibration and validation models using HEC-HMS. Model simulations produced runoff coefficients of 0.6, 0.33, and 0.4 for Lanang Watershed, Pandantoyo, as well as Ngadirejo sub-basin, respectively. A validation of Q rational was performed during the analysis using this model. The K 1 constant rate was defined by dividing the flow calculated by rational method and the flow from HEC-HMS model. Additionally, primary data that was the measurement of the water depth using a logger/AWLR was assumed to be more accurate than data simulation. The validation process improved the advanced HEC-HMS parameters, and the sensitivity analysis identified the most accurate values. The performance of HEC-HMS was assessed using RMSE (Root Mean Square Error) and Nash-Sutcliffe Efficiency, and calibration also assessed the accuracy of the modeling/simulation. The flow calculated using rational method and HEC-HMS should be calibrated, verified, and validated with observed flow data before determining the K value. In conclusion, values obtained from rational formulas provided a more accurate coefficient C based on empirical data.
3 March 2025 in Journal of Marine-Earth Science and Technology
Infiltration is an essential parameter in runoff, although its simulation remains challenging due to soil heterogeneity and complex structures. As soil moisture increases, infiltration capacity decreases nonlinearly, stabilizing when saturation is reached. Therefore, this study aimed to improve and validate the Horton Equation using field observations to determine infiltration capacity in watersheds. Overland flow observations were used to assess simulation accuracy from the previous studies, the sensitivity curve number was obtained at a range of 49–57. The results showed that high precipitation saturated initial losses and infiltration capacity, producing a greater runoff coefficient. The sensitivity curve numbers were obtained differently between Pandantoyo sub-basin (CN 49–53) and Ngadirejo sub-basin (CN 53–55). From modification runoff coefficient values (dimensionless,) for an ungauged catchment, it could be obtained function of f (R24, Sm), LU. Soil moisture value between Pandantoyo and Ngadirejo sub-basin was 3,562. It was also discovered that C was Q from AWLR observation and time of concentration, which influenced water discharge. A longer Tc led to lower discharge without increasing water levels. Furthermore, SCS Direct runoff method had minimal impact on runoff coefficients.
1 January 2026 in Riwayat: Educational Journal of History and Humanities
Mortar busa merupakan inovasi teknologi dengan sifat pemadatan sendiri, sehingga dapat berfungsi sebagai bahan pengganti berkualitas tinggi (tanah bermutu tinggi) untuk material lapisan pondasi ringan. Penelitian ini bertujuan untuk menganalisis pengaruh variasi persentase bahan pembusa dan durasi pengeringan terhadap kepadatan mortar busa. Metode pencampuran penelitian ini meliputi pembuatan campuran dengan variasi persentase bahan pembusa sebanyak 2%, 4%, dan 6%, pengeringan pada interval 7, 14, 21, dan 28 hari, dan menganalisis data kepadatan untuk melihat pola perubahannya. Hasil penelitian dengan tekanan kompresor busa 4 bar, 2% bahan pembusa memperoleh kepadatan 0,709 gr/cm3 dan 4% memperoleh 0,693 gr/cm3 dan 6% memperoleh 0,688 gr/cm3. Hal ini menunjukkan bahwa 6% bahan pembusa memiliki kepadatan terendah, artinya mortar busa paling ringan. Peningkatan jumlah bahan pembusa terbukti menurunkan nilai kepadatan mortar akibat peningkatan volume pori udara dalam matriks mortar, sementara periode pengeringan yang lebih lama berperan dalam menstabilkan struktur pori melalui proses hidrasi semen yang lebih sempurna. Secara teknis, temuan ini dapat digunakan sebagai dasar pengambilan keputusan dalam desain campuran mortar busa, khususnya dalam menentukan dosis bahan pembusa untuk mencapai target kepadatan tertentu sesuai dengan spesifikasi desain. Oleh karena itu, pengendalian bahan pembusa dan waktu pengeringan merupakan faktor penting dalam menentukan kualitas mortar busa.
Sebagian sumber pencemaran sulfur dioksida adalah dari aktivitas manusia seperti gas buangan pabrik maupun kendaraan bermotor. Oleh karena itu, pencegahannya dapat dilakukan oleh manusia sendiri dengan berbagai usaha. Paper ini membahas mengenai upaya pencegahan polusi dari sulfur dioksida dengan menggunakan wet scrubber. Wet scrubber didesain dengan menggunakan mist eliminator tanpa media dan menggunakan air. Variabel dalam penelitian ini adalah debit air, ketinggian sprayer dan susun vertikal sprayer. Gas dianalisis dengan menggunakan metode konduktivitimetri manual. Pengukuran dengan metode ini dapat diaplikasikan pada yang memiliki range ≥0.05 ppm. Hasil yang diperoleh dari penelitian adalah persentase penyisihan untuk satu tingkat sprayer dengan debit terbesar 0,14 Liter/s adalah 74.15%. Satu tingkat sprayer menggunakan ketinggian kolom pada sprayer berjarak 110 cm. Sedangkan untuk dua tingkat prayer dengan ketinggian kolom 110 cm dan 41 cm menghasilkan penyisihan sebesar 97.74%.
Infiltration can be identified as the critical processes in the hydrological process. Infiltration affects the vertical distribution of rainwater on surface water and significantly distresses between groundwater and surface water. Infiltration is one of an important parameters that could affect and increase the runoff. In advance, the Horton Method is the most widely used in hydrology infiltration models for fields research than the others. The objective of this study was to determine a relationship between infiltration capacity and runoff flow to improve the Horton infiltration equation during intermittent rainfall by field work. Research area was located Lanang sub-catchment, Kediri, East Java. Double ring infiltrometer was used to determine field infiltration rate. Land use and soil type maps were used to categorize sampling area and type of soil. Intermittent rainfall data was measured from rain gauge in the study area. According to the analysis, the capacity of infiltration decreases equal to a constant value and the results of infiltration rate from a double ring infiltrometer value obtained was 90 mm/hour at the upstream area. In the other hands, the downstream area resulted 26,4 mm/hour of infiltration rate or 30% out of upstream area value