Since the 1970s, due to the worldwide energy crisis, some countries have adopted severe legislation to promote energy efficiency in buildings. The electrical power utilized in buildings is directly related to the equipment required to provide thermal comfort to occupants. In this context, one of the most important factors that determine the choice of these systems is the conduction load through the building envelope. In several countries, hollow concrete blocks have become common over the past few years. Therefore, for the assessment of building energy efficiency, the thermal transmittance evaluation of hollow blocks is required. This study obtains values of thermal transmittance for different cavity configurations of concrete blocks by performing computational fluid dynamics simulations. These transmittances are compared to those calculated using the methodology presented in international standards. In the “Results” section, it is shown that large cavities provide higher transmittance values due to convection and that thermal radiation may play an important role in the overall heat transfer through concrete hollow blocks. Some methods used to reduce the thermal transmittance are presented and discussed. Finally, thermal transmittance of cavities with the same wall height has been compared with the ones of a single block and different strategies are considered for reducing the thermal transmittance of concrete hollow blocks.
Buildings are responsible for a large part of energy demand worldwide. To collaborate to reduce this demand, this paper aims to present a computational model to analyze the performance of an earth–air heat exchanger (EAHE) based on computational fluid dynamics using the ANSYS/Fluent® software in the simulations. This passive air conditioning system uses the soil as a heat exchanger, taking advantage of the fact that the temperature of the soil at a certain depth remains relatively constant, regardless of the weather conditions above the surface, promoting heating, cooling, or ventilation for buildings. The air temperature values obtained were compared with experimental data from sensors installed in an EAHE at the Federal University of Technology—Parana, Ponta Grossa/Brazil (25.1° South, 50.16° West) to validate the computational model. A high computational effort would be demanded to perform these simulations involving the whole soil domain and the climatic boundary conditions. In order to optimize the numerical analysis of EAHE, two reduced models for the soil and heat exchanger domains were verified. First, a constant temperature of 23.7 °C was imposed on the surface of the exchanger tube, corresponding to the average soil temperature at a depth of 1.5 m. Afterward, a reduced soil domain extending 0.5 m in all directions from the heat exchanger serpentine was considered. Likewise, constant temperatures were imposed on the upper and lower surfaces of the soil domain, also obtained experimentally. In both cases, the temperature values obtained through the fast simulations showed good agreement compared to the experimental values. Barely explored in the literature, the thermal behavior of the two identical indoor environments at the university was also compared, in which the climatized environment, with the EAHE working in a closed loop, obtained milder and smaller amplitude air temperatures.
The hygrothermal analysis of roofs is relevant due to the large areas exposed to a wide range of weather conditions, these directly affecting the energy performance and thermal comfort of buildings. However, after a long life service, the solar absorptivity coatings of roofs can be altered by mould accumulation. Based on two well established mathematical models, one that adopts driving potentials to calculate temperature, moist air pressure and water vapor pressure gradients, and the other to estimate the mould growth risk on surfaces, this research introduces an approach to predict mould growth considering a reduced computational effort and simulation time. By adopting multiple MISO (Multiple-Input, Single-Output) Nonlinear AutoRegressive with eXogenous inputs (NARX) models, a machine learning technique known as Least Squares Support Vector Machines (LS-SVM), a maximum margin model based on structural risk minimization, was used to predict vapor flux, sensible heat flux, latent heat flux, and mould growth risk on roof surfaces. The proposed model was validated in terms of the Multiple Correlation Coefficient (R2R2R2), Mean Square Error (MSE) and Mean Absolute Error (MAE) performance indices considering as input the weather file from Curitiba city—Brazil, showing consistent precision when compared to the results of a validated numerical model.
After the first concerns about global energy consumption around the 70 s, some standards were established with the aim of improving the energy efficiency in buildings. In this context, according to the US Department of Energy, heating, ventilation, and air conditioning (HVAC) systems comprise about 50% of the building energy consumption and 20% of total consumption in the United States. Energy consumption of this kind of equipment depends on several factors, one of the most important factors being the heat transfer through the building envelope. In the walls, hollow concrete blocks have become common in recent years due to advantages such as their strength, their space for pipes and wiring, and fast construction, among others. In order to reduce the thermal load, several forms of insulation were tested on these constructive elements. Thus, effects of the low emissivity, insulating material, radiant shields, and baffles on the inner cavities of the blocks are presented in this paper. Effects of temperature differences between the exterior surfaces on the thermal transmittance and on the combined average heat transfer coefficient inside the cavities are also shown.
The rational use of energy has motivated research on improving the energy efficiency of buildings, which are responsible for a large share of world consumption. A strategy to achieve this goal is the application of optimized thermal insulation on a building envelope to avoid thermal exchanges with the external environment, reducing the use of heating, ventilation and air-conditioning (HVAC) systems. In order to contribute to the best choice of insulation applied to an industrial shed roof, this study aims to provide an optimization tool to assist this process. Beyond the thermal comfort and cost of the insulation, some hygrothermic properties also have been analysed to obtain the best insulation option. To implement this optimization technique, several thermo-energetic simulations of an industrial shed were performed using the Domus software, applying 4 types of insulation material (polyurethane, expanded polystyrene, rockwool and glass wool) on the roof. Ten thicknesses ranging from 0.5cm to 5 cmwere considered, with the purpose of obtaining different thermal comfort indexes (PPD, predicted percentage dissatisfied). Posteriorly, the best insulation ranking has been obtained from the weights assigned to the parameters in the objective function, using the technique of the genetic algorithm (GA) applied to multi-criteria selection. The optimization results showed that polyurethane (PU) insulation, applied with a thickness of 1 cm was the best option for the roof, considering the building functional parameters, occupant metabolic activity, clothing insulation and climate conditions. On the other hand, when the Brazilian standard was utilized, rock wool (2 cm) was considered the best choice.
Resumo Visando à diminuição do consumo de energia em edificações, devido ao uso de equipamentos de aquecimento, ventilação e ar condicionado, observa-se o aproveitamento do solo como fonte de energia. Por sua alta capacidade térmica, o solo atua como um reservatório térmico, aquecendo ou resfriando o ar do ambiente interno das edificações, conforme as condições climáticas aplicadas. Sendo assim, aplicou-se o método dos volumes finitos neste trabalho para análise do desempenho térmico desse tipo de trocador de calor solo-ar (TCSA). Inicialmente, os efeitos das propriedades térmicas do solo, da velocidade de escoamento do ar e do diâmetro do duto no desempenho térmico do TCSA foram investigados em regime permanente, por ser uma condição limite. Além disso, analisaram-se duas configurações para a distribuição do duto no solo (dois e quatro passos). A partir dos resultados, notou-se que o melhor desempenho para o TCSA foi obtido utilizando o solo saturado e operando com uma velocidade de ar de 2,5 m/s em um duto com diâmetro de 0,10 m. Em seguida, observou-se que uma distância entre as linhas de centro dos dutos de 0,5 m foi a mais apropriada. Adicionalmente, executaram-se simulações em regime transiente, empregando-se condições climáticas por meio de funções senoidais.