Eva Brayfindley

Dr. Eva Brayfindley

Pacific Northwest National Laboratory, Richland, Mississippi, USA
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2018 in Nuclear Technology
Verified
Journal Article
Open access
Eva BrayfindleyEva Brayfindley
Eva Brayfindley
RSRalph C Smith
Ralph C Smith
JMJohn Mattingly
John Mattingly
RBRobert Brigantic
Robert Brigantic
Spent fuel monitoring and characterization has been central to safeguards and nuclear facility monitoring for many years. The Digital Cerenkov Viewing Device (DCVD) has been used since the 1980s as a method of defect detection in spent fuel. In recent years, the accounting for large quantities of spent fuel before storage has renewed interest in this relatively quick and inexpensive method. This has an impact not only in safeguards, but also for nuclear power facilities, as accounting can be a long, arduous, and costly process. Additionally, the DCVD demonstrates limited accuracy in more complex cases such as substitution of a fuel rod with steel or a partial defect detection. A second method, gamma emission tomography (GET) has been explored as an improved defect detection method, but is much more expensive and invasive than DCVD. The present investigation identifies deficiencies in both methods and proposes a combination of data gathered from each method to address these deficiencies for improved spent fuel characterization. Initial results are promising, showing 97% detection of a single missing fuel rod when the data types are combined, versus approximately 50% and 70%, respectively, for DCVD and GET data on their own. These classification results are obtained with algorithms derived from facial recognition and applied to this problem, yielding unique accuracy in near real time while also maintaining the information barrier between output and measurement desired in safeguards.

21 October 2023 in Metabolites
Verified
Journal Article
Open access
PDF file
DDDavid J Degnan
David J Degnan
JFJavier E Flores
Javier E Flores
Eva BrayfindleyEva Brayfindley
Eva Brayfindley
VPVanessa Paurus
Vanessa Paurus
BWBobbie-Jo Webb-Robertson
Bobbie-Jo Webb-Robertson
Lisa BramerLisa Bramer
Lisa Bramer
Metabolomics provides a unique snapshot into the world of small molecules and the complex biological processes that govern the human, animal, plant, and environmental ecosystems encapsulated by the One Health modeling framework. However, this “molecular snapshot” is only as informative as the number of metabolites confidently identified within it. The spectral similarity (SS) score is traditionally used to identify compound(s) in mass spectrometry approaches to metabolomics, where spectra are matched to reference libraries of candidate spectra. Unfortunately, there is little consensus on which of the dozens of available SS metrics should be used. This lack of standard SS score creates analytic uncertainty and potentially leads to issues in reproducibility, especially as these data are integrated across other domains. In this work, we use metabolomic spectral similarity as a case study to showcase the challenges in consistency within just one piece of the One Health framework that must be addressed to enable data science approaches for One Health problems. Here, using a large cohort of datasets comprising both standard and complex datasets with expert-verified truth annotations, we evaluated the effectiveness of 66 similarity metrics to delineate between correct matches (true positives) and incorrect matches (true negatives). We additionally characterize the families of these metrics to make informed recommendations for their use. Our results indicate that specific families of metrics (the Inner Product, Correlative, and Intersection families of scores) tend to perform better than others, with no single similarity metric performing optimally for all queried spectra. This work and its findings provide an empirically-based resource for researchers to use in their selection of similarity metrics for GC-MS identification, increasing scientific reproducibility through taking steps towards standardizing identification workflows.

11 July 2023 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
AGAndrew J. Gilbert
Andrew J. Gilbert
BMBenjamin S. McDonald
Benjamin S. McDonald
DKDustin M. Kasparek
Dustin M. Kasparek
RWRichard S. Wittman
Richard S. Wittman
WGWesley C. Gillis
Wesley C. Gillis
LSLucas E. Sweet
Lucas E. Sweet
X-ray radiography offers the ability to noninvasively inspect the internal structure and material composition of objects. Dual-energy radiography allows material discrimination but is limited in quantitative material measurements due to the broad nature of the interrogating x-ray spectrum. Spectral radiography detectors provide an observation of not just the number of x rays that are transmitted through a sample but also the spectrum. Here, experimental validations of a method to use spectral x-ray radiography to accurately quantify the uranium mass in a powder are presented. An accurate system response model was developed, which includes a model of the incident x-ray source spectrum and a pixel-wise detector response that describes how the transmitted x rays were observed. Further, a calibration to account for the effect of partial x-ray attenuation was developed. The method is demonstrated to be capable of estimating the uranium mass in a variety of uranium oxide powders to a bias of −0.01±0.62%.

30 September 2024
Verified
Report
Open access
PDF file
FCFanny Chu
Fanny Chu
JBJessica L. Bade
Jessica L. Bade
JDJoshua L. Durell
Joshua L. Durell
MTMatthew W. Turner
Matthew W. Turner
CDCharles G. Doll
Charles G. Doll
Eva BrayfindleyEva Brayfindley
Eva Brayfindley
Non-targeted analysis of small molecules and metabolites in unknown, complex samples using liquid chromatography-tandem mass spectrometry remains challenging. One of the main bottlenecks is the extensive unannotated regions of metabolomics mass spectrometry data, resulting in knowledge gaps. Small molecule annotation in mass spectrometry data has conventionally relied on reference standards and libraries for compound identification and confirmation, which can constrain compound identification to those molecules already known, thus limiting the ability to discover new knowledge and new markers. Retention time prediction can facilitate and expedite unknown compound identification in non-targeted analysis of complex metabolomics samples. Additionally, accurate retention time predictions can also inform sample mixture design for LC-MS/MS analyses. However, current machine learning-based methods for retention time prediction are typically developed for specific chromatographic platforms and are not generalizable across scales. And while technologies and methods to improve reference-free metabolite identification for more comprehensive annotation of unknowns has received much attention, development of the same for quantitation without reference standards has been much more limited, despite its importance in toxicological, environmental, food safety, forensics, and clinical applications. We believe that a reference-free quantitation strategy that exploits mass spectrometry data already collected for reference-free identification can provide much more insight on unknowns, and move the metabolomics field for more complete unknowns characterization. As such, we pursue two efforts to improve upon current state-of-the-art methods in non-targeted analysis: (1) machine learning-based retention time prediction and (2) statistical design of experiments framework for reference-free quantitation. In this work, we develop and demonstrate (1) a generalizable retention time prediction capability across chromatographic conditions and scales, and (2) a statistical design-based framework for response factor contribution elucidation and reference-free quantitation. Evaluation of our retention time prediction model, PrediToR, showed approximately 24% improvement over current models, and we observed approximately 10X improvement in concentration estimation accuracy from our statistical design-based response factor model over a primarily ionization efficiency-based model. We expect that future efforts to improve upon these new capabilities will further advance non-targeted analysis of small molecules towards truly reference-free metabolomics.