Adedayo Owosuhi

Mr. Adedayo Owosuhi

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2023 in Energies
Verified
Journal Article
Open access
PDF file
AOAdedayo Owosuhi
Adedayo Owosuhi
YHYskandar HAMAM
Yskandar HAMAM
Josiah Lange MundaJosiah Lange Munda
Josiah Lange Munda
The highly variable power generated from a battery energy storage system (BESS)–photovoltaic distributed generation (PVDG) causes harmonic distortions in distribution systems (DSs) due to the intermittent nature of solar energy and high voltage rises or falls in the BESS. Harmonic distortions are major concerns in the DS, especially when the sizes and locations of these resources are sub-optimal. As a result, many studies are being performed on the optimal allocation of BESS/PVDG systems in distribution network systems. In this regard, this paper seeks to review the existing planning models, optimization methods and renewable energy resources that uncertainty models have employed in solving BESS/PVDGs allocation problems in terms of obtaining optimal solutions/allocations and curtailing the harmonic contents of the DSs. However, studies on optimal allocation planning of BESS/PVDGs have achieved minimum cost but were not able to meet the standard harmonic level of the DSs. The results identified GA, PSO and AIS as some of the most used methodologies while LP, MILP and different configurations of NLP were used in the model formulations of BESS/PVDGs problems. The results also revealed DC-link voltage and switching and grid voltage harmonics as the notable causes and sources of harmonic distortions in BESS/PVDG systems. The current allocation models presented in the recent literature for the planning of BESS/PVDGs do not include the variables necessary for curtailing the harmonic contents in their planning formulations. This paper, therefore, recommends an improved and all-encompassing planning model with an efficient intelligent search algorithm capable of obtaining a global optimum solution and curtailing harmonic distortions from the BESS/PVDG-connected DSs.

26 January 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AOAdedayo Owosuhi
Adedayo Owosuhi
YHYskandar HAMAM
Yskandar HAMAM
Josiah Lange MundaJosiah Lange Munda
Josiah Lange Munda
In recent times, a significant amount of power loss and system instability due to high voltage deviation experienced by modern power systems, in addition to the pressing issues challenging the power industry such as pollution—especially the emission of greenhouse gases—and aging infrastructures, have posed a serious threat to system operations. Distributed generation has been identified as one main solution capable of reducing pollution when solar and wind power are used and, hence, rejuvenating dilapidated infrastructures and redeeming climatic changes. This paper presents a novel two-stage approach for the identification of suitable locations for DG placement and the sizing of DG for loss reduction and voltage stability enhancement. The first stage explored the use of a network structure to develop a coupling factor (CF) approach that was non-iterative in nature to determine suitable DG locations. In the second stage, the size of the DG was determined using the particle swarm optimization (PSO) algorithm. The main objective was to obtain an optimal voltage profile of the system under consideration while lowering the power loss in the system and ensuring network stability amidst DG incorporation. The model design, optimization and simulation were carried out using the MATLAB 2016a environment and the IEEE 33-bus test system, in which DG was integrated. The influence of increasing the level of DG placement in the system was then investigated. The forward/backward sweep method was applied to monitor the optimization process. The voltage profiles for both the base case when no DG was integrated and the case of incremental DG integration were considered. The results obtained for both single and multiple DG integration are compared with those obtained using the existing methods. The results show the efficiency and applicability of the new non-iterative scheme in the quick identification of DG locations for voltage profile enhancement and network real power loss reduction in radial distribution networks.