Yan Xuan

Ms. Yan Xuan


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2022 in Crystals
Verified
Journal Article
Open access
PDF file
YXYan Xuan
Yan Xuan
qi guoqi guo
qi guo
HZHuijie Zhao
Huijie Zhao
HZHAO ZHANG
HAO ZHANG
A method for full Stokes polarization imaging based on broadband liquid crystal polarization grating (LCPG) is presented. Firstly, the properties of the LCPG-based polarization detection module, which consists of a phase retarder and a broadband polarization grating in series, were investigated by means of Stokes calculus. The relationship between the polarization state of the incidence and the efficiencies of the diffractions was derived. Then, the azimuth parameters of the polarization detection module were optimized by using an equally weighted variance (EWV) evaluation criterion. Finally, the detection of the linearly and arbitrarily polarized laser beam and a linearly polarized broadband object were experimentally verified. The proposed method provides the design of polarization imaging systems based on LCPGs and has the advantages of compact structure, and broad wavelength coverage, therefore offering potential applications for image polarization information acquisition.

13 May 2023 in Materials
Verified
Journal Article
Open access
PDF file
HZHAO ZHANG
HAO ZHANG
HZHuijie Zhao
Huijie Zhao
qi guoqi guo
qi guo
YXYan Xuan
Yan Xuan
Acousto-optic interaction geometry determines the spectral and spatial response of an acousto-optic tunable filter (AOTF). The precise calibration of the acousto-optic interaction geometry of the device is a necessary process before designing and optimizing optical systems. In this paper, we develop a novel calibration method based on the polar angular performance of an AOTF. A commercial AOTF device with unknown geometry parameters was experimentally calibrated. The experimental results show high precision, in some cases falling within 0.01°. In addition, we analyzed the parameter sensitivity and Monte Carlo tolerance of the calibration method. The results of the parameter sensitivity analysis show that the principal refractive index has a large influence on the calibration results, while other factors have little influence. The results of the Monte Carlo tolerance analysis show that the probability of the results falling 0.1° using this method is greater than 99.7%. This work provides an accurate and easy-to-perform method for AOTF crystal calibration and can contribute to the characteristic analysis of AOTFs and the optical design of spectral imaging systems.