Yue Li

Mr. Yue Li


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2024 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
YLYue Li
Yue Li
LYli yue
li yue
XHXiaomeng He
Xiaomeng He
BHBoyang Huang
Boyang Huang
YFYang Fang
Yang Fang
XHXin-Yi He
Xin-Yi He

23 February 2024 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
YCYongxiang Cai
Yongxiang Cai
XXXiao Xiaobing
Xiao Xiaobing
YLYue Li
Yue Li
XHXiaomeng He
Xiaomeng He
XHXinyi He
Xinyi He
BHBoyang Huang
Boyang Huang


20 May 2026 in Frontiers in Energy Research
Verified
Journal Article
Open access
PDF file
YLYue Li
Yue Li
ALAnjiang Liu
Anjiang Liu
YZYouzhuo Zheng
Youzhuo Zheng
SHShuqing Hao
Shuqing Hao
WHWei Huang
Wei Huang
YZYinghu Zhao
Yinghu Zhao
With the increase in extreme weather events, icing disasters pose a significant threat to the safe and stable operation of distribution lines. In this study, a finite element model for stress analysis of iced conductors is established, and the dynamic stress characteristics of three types iced conductors under fluctuating wind conditions are analyzed, with particular attention given to the effects of varying ice thicknesses and wind speeds on the maximum conductor stress. Results show that JKLYJ-10/70 exceeds its tensile limit at an ice thickness of 27 mm, JL/G1A-50/8 reaches its tensile capacity around 47 mm, while JL/G1A-120/20 remains within safe limits even with 50 mm of ice. To achieve accurate dynamic stress prediction, a hybrid model combining a Long Short-Term Memory network and Dynamic Kalman Filtering is proposed. Under the condition of 10 mm ice thickness and 15 m/s wind speed, the proposed method achieves the lowest root mean square error among all compared algorithms, with a value of only 17.02 N, and the model also exhibits the lowest mean absolute error with a value of 16.69 N. The power spectral density exhibits dominant peaks at 1.76 Hz and 2.3 Hz, with the proposed method providing the closest agreement. Relative errors at these frequencies are only 2.49% and 0.78%, indicating that the proposed method more effectively captures the dynamic stress response of iced conductors under fluctuating wind conditions.

1 December 2025 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
YLYue Li
Yue Li
YXYutao Xu
Yutao Xu
CDChen Dou
Chen Dou
ALAnjiang Liu
Anjiang Liu
CLChangtao Li
Changtao Li
During the melting process, the ice coating of the line will lead to additional energy consumption and increase the melting time due to the latent heat of ice phase change. In this paper, the theoretical analysis of the phase transition latent heat stage and the phase transition latent heat stage of ice melting is carried out, and a theoretical model and modeling method of the phase transition latent heat stage of ice-covered circuit are put forward. The equivalent thermal circuit model is used to complete the temperature rise process analysis of the phase transition latent heat stage and the thermophysical analysis of the phase transition latent heat stage respectively, and the heat flow and temperature change of the ice-covered circuit in the phase transition latent heat stage and the phase transition latent heat stage are comprehensively given. Finally, an example is listed and a comparative test is carried out to verify the effectiveness of the model.