Danzhu Danzhu Zhu Zhu

Dr. Danzhu Danzhu Zhu Zhu


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
DZDanzhu Danzhu Zhu Zhu
Danzhu Danzhu Zhu Zhu
BLBin Liu
Bin Liu
Gang WeiGang Wei
Gang Wei
Two-dimensional (2D) materials such as graphene, graphene oxide, transition metal oxide, MXene and others have shown high potential for the design and fabrication of various sensors and biosensors due to their 2D layered structure and unique properties. Compared to traditional fluorescent, electrochemical, and electrical biosensors, colorimetric biosensors exhibit several advantages including naked-eye determination, low cost, quick response, and easy fabrication. In this review, we present recent advances in the design, fabrication, and applications of 2D material-based high-performance colorimetric biosensors. Potential colorimetric sensing mechanisms and optimal material selection as well as sensor fabrication are introduced in brief. In addition, colorimetric biosensors based on different 2D materials such as graphene, transition metal dichalcogenide/oxide, MXenes, metal–organic frameworks, and metal nanoplates for the sensitive detection of DNA, proteins, viruses, small molecules, metallic ions, and others are presented and discussed in detail. This work will be helpful for readers to understand the knowledge of 2D material modification, nanozymes, and the synthesis of hybrid materials; meanwhile, it could be valuable to promote the design, fabrication, and applications of 2D material-based sensors and biosensors in quick bioanalysis and disease diagnostics.

10 May 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XZXiaoting Zhang
Xiaoting Zhang
HKHao Kong
Hao Kong
GYGuozheng Yang
Guozheng Yang
DZDanzhu Danzhu Zhu Zhu
Danzhu Danzhu Zhu Zhu
XLxin luan
xin luan
Gang WeiGang Wei
Gang Wei
Graphene-based nanomaterials have shown wide applications in antimicrobial fields due to their accelerated rate of pathogen resistance and good antimicrobial properties. To apply graphene materials in the antimicrobial test, the graphene materials are usually fabricated as two-dimensional (2D) membranes. In addition, to improve the antimicrobial efficiency, graphene membranes are modified with various functional nanomaterials, such as nanoparticles, biomolecules, polymers, etc. In this review, we present recent advances in the fabrication, functional tailoring, and antimicrobial applications of graphene-based membranes. To implement this goal, we first introduce the synthesis of graphene materials and then the fabrication of 2D graphene-based membranes with potential techniques such as chemical vapor deposition, vacuum filtration, spin-coating, casting, and layer-by-layer self-assembly. Then, we present the functional tailoring of graphene membranes by adding metal and metal oxide nanoparticles, polymers, biopolymers, metal–organic frameworks, etc., with graphene. Finally, we focus on the antimicrobial mechanisms of graphene membranes, and demonstrate typical studies on the use of graphene membranes for antibacterial, antiviral, and antifungal applications. It is expected that this work will help readers to understand the antimicrobial mechanism of various graphene-based membranes and, further, to inspire the design and fabrication of functional graphene membranes/films for biomedical applications.

19 May 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
RMRongqiu Mu
Rongqiu Mu
DZDanzhu Danzhu Zhu Zhu
Danzhu Danzhu Zhu Zhu
Gang WeiGang Wei
Gang Wei
Nitrites widely exist in human life and the natural environment, but excessive contents of nitrites will result in adverse effects on the environment and human health; hence, sensitive and stable nitrite detection systems are needed. In this study, we report the synthesis of Ti3C2 nanosheets functionalized with apoferritin (ApoF)–biomimetic platinum (Pt) nanoparticle (Pt@ApoF/Ti3C2) composite materials, which were formed by using ApoF as a template and protein-inspired biomineralization. The formed nanohybrid exhibits excellent electrochemical sensing performance towards nitrite (NaNO2). Specifically, the Pt@ApoF catalyzes the conversion of nitrites into nitrates, converting the chemical signal into an electrical signal. The prepared Pt@ApoF/Ti3C2-based electrochemical NaNO2 biosensors demonstrate a wide detection range of 0.001–9 mM with a low detection limit of 0.425 μM. Additionally, the biosensors possess high selectivity and sensitivity while maintaining a relatively stable electrochemical sensing performance within 7 days, enabling the monitoring of NaNO2 in complex environments. The successful preparation of the Pt@ApoF/Ti3C2 nanohybrid materials provides a new approach for constructing efficient electrochemical biosensors, offering a simple and rapid method for detecting NaNO2 in complex environments.

22 December 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
DZDanzhu Danzhu Zhu Zhu
Danzhu Danzhu Zhu Zhu
HKHao Kong
Hao Kong
GYGuozheng Yang
Guozheng Yang
PHPeng He
Peng He
XLxin luan
xin luan
Gang WeiGang Wei
Gang Wei
Hydrogen peroxide (H2O2) is one of the intermediates or final products of biological metabolism and participates in many important biological processes of life activities. The detection of H2O2 is of great significance in clinical disease monitoring, environmental protection, and bioanalysis. In this study, Ti3C2-based nanohybrids are prepared by the biological modification and self-assembled peptide nanosheets (PNSs)-based biomimetic synthesis of copper sulfide nanoparticles (CuS NPs), which show potential application in the fabrication of low-cost and high-performance electrochemical H2O2 biosensors. The synthesized CuS-PNSs/Ti3C2 nanohybrids exhibit excellent electrochemical performance towards H2O2, in which CuS NPs can catalyze the decomposition of H2O2 and realize the transformation from a chemical signal to an electrical signal to achieve the purpose of H2O2 detection. The prepared CuS-PNSs/Ti3C2-based electrochemical biosensor platform exhibits a wide detection range (5 μM–15 mM) and a low detection limit (0.226 μM). In addition, it reveals good selectivity and stability and can realize the monitoring of H2O2 in a complex environment. The successful biomimetic synthesis of CuS-PNSs/Ti3C2 hybrid nanomaterials provides a green and friendly strategy for the design and synthesis of functional nanomaterials and also provides a new inspiration for the construction of highly effective electrochemical biosensors for practical detection of H2O2 in various environments.