Yeonwoo Yu

Mr. Yeonwoo Yu


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2026 in Medicina
Verified
Journal Article
Open access
PDF file
YPYong Seok Park
Yong Seok Park
YYYeonwoo Yu
Yeonwoo Yu
HCHari Cha
Hari Cha
JLJoonseok Lee
Joonseok Lee
CYChan Yoon
Chan Yoon
KLKikwang Lee
Kikwang Lee
Background and Objectives: This study aimed to verify the validity of markerless gait analysis using both single-camera markerless system (S-ML) and multi-camera markerless system (M-ML) approaches by comparing them with a gold-standard marker-based system (MB). Materials and Methods: Sixteen healthy adults walked at their gait speed, and their gaits were simultaneously analyzed using three systems: S-ML, M-ML, and MB. Intraclass correlation coefficients were used to assess the reliability of the spatiotemporal parameters, and the root mean squared error (RMSE) was calculated to quantify the kinematic differences relative to the MB systems. Results: Both S-ML and M-ML demonstrated good-to-excellent reliability in spatiotemporal parameters, including step length, stance time, and gait speed, whereas stride length and swing time measured by S-ML revealed moderate reliability. In terms of joint kinematics, S-ML demonstrated a performance comparable to that of M-ML, particularly at the hip and knee in the sagittal plane. For certain parameters, such as knee abduction/adduction in the frontal plane, the S-ML demonstrated lower RMSE values than M-ML. In contrast, the ankle joint angles estimated using S-ML exhibited reduced agreement. Conclusions: In conclusion, markerless gait analysis can serve as an alternative to conventional gait analysis. However, certain parameters need to be improved.

28 December 2023 in Electronics
Verified
Journal Article
Open access
PDF file
SHSang Kuy Han
Sang Kuy Han
JKJeong-Bae Ko
Jeong-Bae Ko
YYYeonwoo Yu
Yeonwoo Yu
JHJaesoo Hong
Jaesoo Hong
JRJei-Cheong Ryu
Jei-Cheong Ryu
SKSung-Jae Kang
Sung-Jae Kang
A compromised stability in the elderly population is considered a major factor for fall risk assessment. The dynamic stability of human gait with various mathematical metrics has been extensively studied to find a prediction index and fall prevention strategies that can be embedded in a wearable monitoring sensor. In this study, the zero-moment point method (ZMP) was utilized for analyzing the gait stability of young and elderly female populations. Participants in the young and elderly female groups with no musculoskeletal disorders and fall experience were asked to walk at a habitual speed on 10 m flat ground. Dynamic instability is defined by the percentage of the ZMP values that fall outside the base of support during one gait cycle. The ZMP trajectory between the left and right leg swing was not symmetrical considering flat-ground walking. Also, there was no statistical difference in the dynamic stability in the anterior–posterior direction (71.3 ± 7.9% for the young group and 73.6 ± 7.6% for the elderly group), but walking in the medial–lateral direction was more stable in the elderly group (53.9 ± 8.6%) than in the young group (44.1 ± 11.2%) because the habitual walking speed decreased in the elderly group.

26 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
DSDongwook Seo
Dongwook Seo
JEJinsu Eun
Jinsu Eun
YYYeonwoo Yu
Yeonwoo Yu
SPSangsoo Park
Sangsoo Park
KLKikwang Lee
Kikwang Lee
The shoe upper hides the foot motion on the insole, so it has been challenging to measure the non-slip function of socks in a dynamic motor task. The study aimed to propose a method to estimate the non-slip function of socks in an acute maneuver. Participants performed a shuttle run task while wearing three types of socks with different frictional properties. The forces produced by foot movement on the upper during the task were measured by pressure sensors installed at the upper. A force platform was also used to measure the ground reaction force at the outsole and ground. Peak force and impulse values computed by using forces measured by the pressure sensors were significantly different between the sock conditions, while there were no such differences in those values computed by using ground reaction forces measured by a force platform. The results suggested that the non-slip function of socks could be quantified by measuring forces at the foot-upper interface. The method could be an affordable option to measure the non-slip function of socks with minimal effects from skin artifacts and shoe upper integrity.