Background: Invasive placental disorders are potentially life-threatening. Its diagnosis and evaluation of degree of invasiveness is vital in surgical and treatment planning. Purpose: To compare the role of various imaging modalities used in current practice for evaluation of invasive placental disorders, and evaluate the validity of certain imaging signs for prediction of invasive placenta. Material and Methods: Twenty-two patients, which were clinically stratified as a risk group for underlying invasive placental abnormality, underwent Doppler sonography and magnetic resonance imaging (MRI). Abnormal placental invasiveness was assessed using various Doppler sonography and MRI signs described in the existing literature. We systematically evaluated the utility of each of these modalities and signs, and compared the roles played by them separately and in combination. All the cases were correlated with surgical and pathological findings. Results: Nine patients had surgical and pathological confirmation of placental adhesive disorders, of which eight were predicted correctly by MRI (true positive) while one was misdiagnosed as normal placenta (false negative). All the nine cases were correctly identified by Doppler sonography. MRI was more accurate in predicting bladder invasion, identifying 5/6 cases. Conclusion: Both MRI and Doppler sonography are useful for detection of invasive placental disorders. However, MRI is a better predictor of bladder invasion.
28 February 2022 in Indian Journal of Radiology and Imaging
Aim The aim of this article was to evaluate uterocervical angle (UCA) and cervical length (CL) measured at 16 to 24 weeks of gestation using transvaginal sonography (TVS) as predictors of spontaneous preterm birth.Methods In this prospective study, TVS was performed in 159 primigravidas with a singleton, uncomplicated pregnancy at 16 to 24 weeks of gestation to measure the anterior UCA and CL. All the cases were followed until labor to document gestational age at delivery.Results The risk of spontaneous preterm birth was higher in women with obtuse UCA (>95 degrees) with sensitivity of 86.7%, specificity of 93.0%, positive predictive value of 83.0%, negative predictive value of 94.6%, and p-value of <0.001. The difference between the means was statistically significant (p-value < 0.001). UCAs ≥105degrees and 95 to 105 degrees were found to be significantly associated with spontaneous preterm births at <34 weeks and 34 to 37 weeks, respectively. CL <2.5 cm was found to predict spontaneous preterm births at <37 weeks with sensitivity of 31.1%, specificity of 95.6%, and p-value of <0.001. UCA was found to be a better predictor of spontaneous preterm birth with a higher coefficient of variation (56.4%) when compared with CL (16.9%).Conclusions UCA proved to be a novel ultrasound parameter that can serve as a better predictor of spontaneous preterm births in comparison to CL. A strong correlation exists between obtuse UCA and a risk of spontaneous preterm birth.
We report two infants presenting with unilateral congenital facial palsy since birth. Magnetic resonance imaging (MRI) in both the cases revealed complete unilateral aplasia of facial nerve. To our knowledge, this is the first reported MR depiction of nonsyndromic isolated facial nerve aplasia. Imaging features and the pertinent anatomy is discussed along with a brief review of literature.
27 January 2024 in Indian Journal of Radiology and Imaging
: Nocardiosis is a rare opportunistic infection mostly affecting the lungs, brain, or skin of immunocompromised individuals. Most pulmonary nocardiosis patients present with nonspecific clinical features such as productive cough, exertional dyspnea, and fever. The disease is uncommonly suspected, especially in tuberculosis-endemic regions, and clinical diagnosis is often delayed, resulting in high mortality. Pulmonary nocardiosis in apparently immunocompetent individuals is uncommon. Here, we present the case of an elderly gentleman with a background history of poorly controlled diabetes but no history of systemic steroid use who presented with worsening symptoms of chronic obstructive pulmonary disease in the form of productive cough and dyspnea. The patient had diffuse crepitations in bilateral lung fields and an arterial oxygen saturation of 86% at admission. Sputum microscopy revealed gram-positive filamentous bacteria that could be successfully cultured and identified as Nocardia amamiensis on 16S ribosomal RNA sequencing. Contrast-enhanced computed tomography of the lungs revealed cavitary nodules and consolidation. The patient responded well to treatment with specific antibiotics based on sensitivity patterns. Because of the nonspecific clinical and radiological findings in pulmonary nocardiosis, a high index of suspicion is required, especially in tuberculosis-endemic regions.